N317NB
Service difficulty reports · 178
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N317NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N317NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1210123117Floorbeam · corrodedAFT CABIN FR 68 FLOORBEAM -Y1292 CORRODED. BLENDED AREA IAW SRM 51-74-00. CHECKED LIMITS L=5" W=3" D=.050". FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14 FIG 102. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-11.SDR DALA1210113117Floorbeam · corrodedAFT CABIN BETWEEN FR 66 FLOORBEAM -Y1292 CORRODED. BLENDED AREA IAW SRM 51-74-00. CHECKED LIMITS L=4" W=3" D=.060". FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14 FIG 102. REMOVED & REPLACED FLOORBEAM IAW SRM 51-42-11.SDR DALA1210103117Floorbeam · corrodedAFT CABIN FR 68 FLOORBEAM Y765 CORRODED. BLENDED FLOORBEAM, CHECKED LIMITS. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REMOVED FLOORBEAM IAW SRM 51-42-11. INSTALLED NEW FLOORBEAM IAW SRM 51-42-11. CAD PLATED BUSHINGS IAW SRM 51-21-11. INSTALLED BUSHINGSSDR DALA1210073117Floor Support · corrodedAFT CABIN BETWEEN FR 64 & 66 FLOOR SUPPORT Y1292 CORRODED. BLENDED CORROSION IAW SRM 51-74-00. DIM AFTER BLEND OUT ARE L=1.2" W=1.45" D=0.077", FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. REMOVED DAMAGED FLOOR SUPPORT IAW SRM 51-42-11. INSTALLED NSDR DALA1210063117Floor Support · corrodedAFT CABIN BETWEEN FR 68 & 69 FLOOR SUPPORT Y1292 CORRODED. BLENDED CORROSION IAW SRM 51-74-00. DIM AFTER BLEND OUT ARE L=1.52" W=0.908" D=0.082". FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG 102. REMOVED DAMAGED FLOOR SUPPORT IAW SRM 51-42-11. INSTALLEDSDR DALA1210053117Floor Support · corrodedAFT CABIN BETWEEN FR 67 & 68 FLOOR SUPPORT Y1292 CORRODED. BLENDED CORROSION IAW SRM 51-74-00 DIM AFTER BLEND OUT ARE L=1.2" W=1.45" D=0.080", FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14 FIG 102. REMOVED DAMAGED FLOOR SUPPORT IAW SRM 51-42-11. INSTALLED NEWSDR DALA1210043117Sill · corrodedAFT CABIN RT DOOR, SILL PLATE CORRODED IN SEVERAL AREAS. REMOVED AND REPLACED DOOR SILL IAW SRM 51-42-11. INSTALLED FWD AND AFT DOOR SHAPE SEAL IAW SRM 51-42-11. BLENDED CORROSION IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW SRM 53-41-14 FIG 101.SDR DALA1210033117Sill · corrodedAFT CABIN LT DOOR, SILL PLATE CORRODED IN SEVERAL AREAS. REMOVED & REPLACED DOOR SILL IAW SRM 51-42-11. REPLACED AFT CORNER FITTING. REPLACED TWO SPLICE COUPLINGS IAW SRM 51-42-11. BLENDED CORROSION IAW SRM 51-74-00. CHECKED LIMITS DIMENSION L=0.450" W=1.SDR DALA1209793117Floor Support · corrodedAFT CABIN BETWEEN FR 65 & 66 FLOOR SUPPORT CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. REMOVED FLOOR SUPPORT IAW SRM 51-42-11. INSTALLED NEW FLOOR SUPPORT IAW SRM 51-42-11. ORIG MAT 0.160" DAMAGE DIM L=1.200" SDR DALA1209783117Floor Panel · damagedAFT CABIN WET AREA FLOOR PANEL 261PF,ON BOTTOM HAS MISSING LAYER OF MATERIAL APPROXIMATELY (1) 26"L X 1"W, (2) 6"L X .5"W. FABRICATED FLOOR PANEL PER DWG 3D25-40640.SDR DALA1209773117Floor Panel · damagedAFT CABIN WET AREA FLOOR PANEL 261CG HAS MISSING LAYER APPROXIMATELY 25.5"L 1'W ON THE BOTTOM. FABRICATED FLOOR PANEL PER DWG 3D25-40640.SDR DALA1208963117Floor Panel · damagedAFT CARGO BAY FLOOR PANEL 151BE DAMAGE BEYOND LIMITS IAW SRM 53-02-00. FABRICATED FLOOR PANEL PER DWG 3D25-40640.SDR DALA1208953117Floor Panel · damagedFWD CARGO BAY FLOOR PANEL 131CF DAMAGED BEYOND LIMITS IAW SRM 53-02-00. FABRICATED FLOOR PANEL PER DWG 3D25-40640.SDR DALA1208943117Floor Panel · damagedFWD CARGO COMPARTMENT FLOOR PANEL 121EG DAMAGED BEYOND LIMITS IAW SRM 53-02-00. FABRICATED FLOOR PANEL PER DWG 3D25-40640.SDR DALA1208933117Floor Panel · damagedFWD CARGO COMPARTMENT FLOOR PANEL 132DG DAMAGE BEYOND LIMITS IAW SRM 53-02-01. FABRICATED FLOOR PANEL PER DWG 3D25-40640.SDR DALA1208923117Floor Panel · damagedFWD CARGO COMPARTMENT FLOOR PANEL 131DG DAMAGED BEYOND LIMITS IAW SRM 53-02-00. FABRICATED FLOOR PANEL PER PER DWG 3D25-40640.SDR DALA1208913117Floor Panel · damagedFORWARD CARGO COMPARTMENT FLOOR PANEL 132EG DAMAGE BEYOND LIMITS IAW SRM 53-02-00. FABRICATED FLOOR PANEL PER DWG 3D25-40640.SDR DALA1208903117Floor Panel · puncturedAFT UTILITY FLOOR PANEL 261DF HAS A PUNCTURE MEASURING L=1.5" X W=1.5", PANEL HAS ALSO WATER INSIDE. FABRICATED FLOOR PANEL IAW DWG 3D25-40640.SDR DALA1208893117Floor Support · corrodedCORRODED FLOOR SUPPORT AT R1 DOOR LOWER AFT CUTOUT ALONG FR 20. REMOVED CORROSION IAW SRM 51-74-00. L=2.0 W=2.0 D=.011 ORIG MAT .071 FOUND TO BE OUT OF LIMITS IAW SRM 51-73-11. REMOVED FLOOR SUPPORT IAW SRM 51-42-11. LOCATED AND DRILLED NEW FLOOR SUPPORT IASDR DALA1208793117Floorbeam · corrodedAFT CABIN BETWEEN FR 65 & 66 FLOORBEAM Y765 CORRODED. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-11. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15, AFTER CORROSION REMOVAL. ORIG MAT. 0.157" DAMAGE DIM. L=1" W=1" D=.035".SDR DALA1208803117Floorbeam · corrodedAFT CABIN, BETWEEN FR 66 & 68. FLOORBEAM Y765 CORRODED. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-42-11. FOUND TO BE OUT OF LIMITS IAW SRM 53-41-15. AFTER CORROSION REMOVAL, ORIG MAT. 0.157" DAMAGE DIM. L=2.6" W=.80" D=.035".SDR DALA1208253117Floor Panel · corrodedFWD ENTRY WAY FLOOR PANEL 222FF HAS CORROSION ON UNDER SIDE OF PANEL. REPLACED PANEL IAW A319 SRM 51-72-11.SDR DALA1208233117Floor Panel · corrodedFWD ENTRY WAY FLOOR PANEL 221FF HAS CORROSION ON UNDER SIDE OF PANEL. REPLACED PANEL IAW A319 SRM 51-72-11.SDR DALA1208223117Floor Panel · corrodedAFT CABIN ENTRY WAY FLOOR PANEL 261FF HAS CORROSION ON UNDER SIDE OF PANEL. REPLACED AFT CABIN ENTRY WAY FLOOR PANEL 261FF WITH NEW PANEL IAW A319 SRM 51-72-11.SDR DALA1208213117Seat Track · corrodedCABIN SEAT TRACK, Y1292, HAS CORRODED SECTIONS FROM FR18-FR21. REMOVED CORROSION IAW A319 SRM 51-74-00. DIM OF REWORKED AREA IS: L-2.3" W=0.70" D=0.062" ORIG MAT=.079. FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-11-15 FIG 102 SHEET 1. REMOVED AND REPLACED SESDR DALA1208203117Floor Support · corrodedCABIN FLOOR SUPPORT Y503.2 FR16 HAS CORROSION. REMOVE AND REPLACED TRACK SUPPORT WITH NEW PART IAW A319 SRM 51-42-11. REMOVED CORROSION IAW A319 SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS. ORIG. MAT. 0.149" DAMAGE DIM L=1.4" W=1.35" D=0.139".SDR DALA1208193117Sill · corrodedAFT CABIN FR 66 FLOOR SHAPE SILL CORRODED. BLENDED CORROSION IAW A319 SRM 51-74-00, L=1.450", W=.320" D=.038" FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-41-14 FIG 101. LOCATED AND DRILLED NEW SHAPE SILL IAW A319 SRM 51-46-11 AND SRM 51-44-11. INSTALLED NEW SDR NWAA085573117Valve · malfunctionedDURING CLIMB OUT OF MSP, AROUND 17,000` HAD A LOW GREEN PRESS ON ENGINE NR 1 PUMP, THEN GREEN RESERVOIR LO LEVEL WARNING. COMPLIED WITH COM PROCEDURES. LANDING GEAR GRAVITY EXTENDED, LANDING UNEVENTFULLY, WITH TOW TO GATE. REPLACED LANDING GEAR SAFETY VALVE
Back to N317NB