Service difficulty report · Floorbeam · Airbus A319114

Difficulty date
February 18, 2012
Submitted
February 23, 2012
Operation
Air carrier
Aircraft
N317NB
Make and model
Airbus A319114
Aircraft serial
1324
Aircraft time
4,852 hours, 2,783 cycles
Part
Floorbeam
Condition
Corroded
Location
Cabin
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFT CABIN FR 68 FLOORBEAM Y765 CORRODED. BLENDED FLOORBEAM, CHECKED LIMITS. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REMOVED FLOORBEAM IAW SRM 51-42-11. INSTALLED NEW FLOORBEAM IAW SRM 51-42-11. CAD PLATED BUSHINGS IAW SRM 51-21-11. INSTALLED BUSHINGS AND BOLTS IAW SRM 51-42-11. BUSHINGS FABRICATED PER DWG D53471168. DAMAGE DIM. L=1.2" W=0.40" D=.027".