N318NB
Service difficulty reports · 181
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N318NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N318NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2019101505907Door Frame · crackedL1 DOOR FRAME 16, STOP FITTING NR 7, STRINGER 10L WAS FOUND TO HAVE A CRACK INDICATION ON THE NR 3 HOLE. ACCOMPLISHED PR/I 581976-14AD REV 0,1,2 AND 3 AND COMPLIED WITH ER/A 581976-14AD REV ORIGINAL.SDR DALA2019101505906Door Frame · crackedFRAME 16L, NR 1 FITTING, NR 3 HOLE HAD A CRACK INDICATION. ACCOMPLISHED PR/I 581976-14AD REV 0,1,2 AND 3 AND COMPLIED WITH ER/A 581976-14AD REV ORIGINAL.SDR DALA2019101305874Window · crackedF/O'S AFT FIXED WINDOW CRACKING AND DELAMINATING ALONG LWR AND AFT EDGE. REMOVED AND REPLACED THE CO-PILOT AFT FIXED WINDOW REF. A319 AMM 56-11-12SDR DALA2019101005827Frame · crackedAFT L/H F/A SEAT FRAME CRACKED AT SEAT MOUNTING HOLE. REMOVED AND REPLACED F/A SEAT PER A319 AMM 25-22-41.SDR DALA201805773138Bottle · low pressureRIGHT FORWARD DOOR ASSIST BOTTLE LOW. SERVICED EMERGENCY OPERATION CYLINDER. CHECKED OKAY.SDR DALA2017101107585Frame Splice · crackedFRAME 68 SPLICE CRACKED, STRINGER 24L, REPLACED THE FRAME SPLICE IAW SRM 51-72-11 AND DRAWING D53474250.SDR DALA2017101007584Floor Support · corrodedFLOOR SUPPORT CORRODED, -Y1225 BETWEEN FRAMES 66 TO 68, REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DWG D53472780, AND DWG D53472816.SDR DALA2017100907385Frame Splice · crackedCRACKED FRAME 68 ON SPLICE CONNECTION AT STRINGER 24R. REPLACED THE SPLICE IAW SRM 51-72-11 AND DRAWING D53474250SDR DALA2017100807383Floorbeam · corrodedCORROSION ON THE FLOORBEAM +Y765, FRAME 66, REPLACED THE FLOORBEAM IAW SRM 51-42-11, 51-72-11, AND DWG D10N01048.SDR DALA2017100107261Floor Support · corrodedCORROSION FLOOR SUPPORT -Y765 AT FRAME 20, FWD GALLEY AREA. REPLACED THE FLOOR SUPPORT BETWEEN FRAMES 12 - 24 IAW SRM 51-72-11 AND DRAWING D53112812.SDR DALA2017093007260Floor Support · corrodedCORRODED FLOOR SUPPORT +Y254 AT FRAME 16 AT FWD GALLEY AREA, REPLACED THE FLOOR SUPPORT BETWEEN FRAMES 12 - 24 ON FWD GALLEY AREA IAW SRM A319 51-72-11 AND DWG D53112816SDR DALA2017093007259Floor Support · corrodedCORRODED FLOOR SUPPORT -Y254 AT FRAME 19, FWD GALLEY AREA, REPLACED THE FLOOR SUPPORT BETWEEN FRAMES 12 AT 24.SDR DALA2017093007258Floor Support · corrodedCORROSION FLOOR SUPPORT Y1292 BETWEEN FRAMES 16 TO 17, FWD GALLEY AREA.SDR DALA2017092907257Floor Support · corrodedCORROSION FLOOR SUPPORT AT FRAME 15, FWD GALLEY AREA, REPLACED FLOOR SUPPORT BETWEEN FRAMES 12 TO 16, Y-81 IAW SRM 51-72-11 AND DWG D5311-2829SDR DALA2017092807140Dummy Rail · corrodedCORROSION DUMMY RAIL Y503.2, FRAME 16 IN THE FWD GALLEY AREA, REPLACED DUMMY RAIL IAW SRM A319 51-72-11 AND DWG D53112825.SDR DALA2017092607138Floor Support · corrodedCORROSION ON THE FLOOR SUPPORT Y1162.5 BETWEEN FRAMES 68 TO 69 IN THE AFT GALLEY AREA, REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DWG D53472780SDR DALA2017031302018Wire · openAFT CABIN WALL PARTITION RED EMERGENCY LIGHT INOPERATIVE. FOUND OPEN WIRES LEADING INTO BASE OF SEAT 29DEF ON SOCKET. TERMINATED THE SOCKET.SDR DALA2017012900720Box Beam · crackedLEFT MLG WHEEL WELL BOX BEAM UPPER FLANGE AT FRAME 43 CRACKED. REPAIRED IAW AMDS 5310-01450-02.SDR DALA2017010800156Housing · damagedEMERGENCY SEAT MOUNTED LIGHTING DAMAGED, REPLACED SEAT SHROUD EMERGENCY LIGHT HOUSING SEAT 25E.SDR DALA2017010300114Housing · looseEMERG LIGHT AT 25D HOUSING LOOSE, REPAIRED EMERGENCY LIGHT HOUSING.SDR DALA2015112107209Skin · damagedRT AILERON L/E LOWER SURFACE COMPOSITE FILLER IS DAMAGED, CRACKED AND WORN. FILLED AILERON LOWER SURFACE IAW SRM 57-61-21.SDR DALA2015111807056Shear Plate · corrodedAFT CABIN AFT SHEAR PLATE AT FRAME 69 AND FRAME 70 Y+1732 HAS CORROSION, REMOVED CORROSION AT AREA IAW SRM 51-74-00, DIM: L=2.0", W=1.0", D=.019". NO ESTABLISHED LIMITS IAW SRM, REPLACED 1EA NEW SHEAR PLATE, PN D5347112420200 IAW SRM 51-42-11,SDR DALA2015111707055Floor Panel · delaminatedAFT CARGO BAY SLOPE WALL PANEL 151 DE IS DELAMINATED 7" X 7 ". FABRICATED SLOPE PANEL 151 DE PN D5367302800000 ON TRAVELER T15/1171285 IAW DWE NW3025-40532.SDR DALA2015111707054Floor Panel · delaminatedAFT CARGO SLOPE PANEL 151 AE IS DELAMINATED 6" X 12". FABRICATED SLOPE WALL PANEL 151 AE, PN D5367302100000 ON TRAVELER TR 15/1151282 IAW NW3025-40532.SDR DALA2015111707053Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151CE IS DELAMINATED 4" X 10", FABRICATED NEW FLOOR PANEL, PN D5367324400000 ON TRAVELER T15/1171292 IAW DWG 3D25-40532.SDR DALA2015111407052Trunnion · damagedLEFT INBD FLAP TRUNNION HAS DAMAGE OUTSIDE THE INSPECTION AREA. REPAIR IAW 536016-14AD.SDR DALA2015111006931Seat Track · corrodedMAIN CABIN SEAT TRACK Y 1292 AT FRAME 20 HAS CORROSION, CORRODED AREA MAIN CABIN SEAT TRACK Y-1292 AT FRAME 20, W=0.36", L=0.60", DEPTH=0.065". FOUND TO BE OUT OF LIMITS IAW SRM 53-00-15, FIGURE 101, USING T12168. R & R SEAT TRACK IAW SRM 51-42-11 AND TRM 53SDR DALA2015110606775Floor Support · corrodedY765 FLOORBEAM FRAME 66-68 HAS CORROSION. REPLACED 1 EA NEW FLOORBEAM, PN D5347219220000 AT MAIN CABIN BETWEEN FR 66-68, Y765 IAW SRM 51-42-11, L=1.0", W=.500", D=.030" DAMAGED DIMENSION FOUND TO BE OUT OF LIMITS IAW SRM 53-41-15.SDR DALA2015110606774Floor Support · corrodedY-765, FLOORBEAM HAS CORROSION BETWEEN FRAME 67-70. REPLACED IAW SRM 51-42-11 AND SRM 51-41-15SDR DALA2015110406723Floor Support · corrodedY+1292 HAS CORROSION BETWEEN FRAME 67-68 FLOORBEAM. BLENDED AREA AND FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REPLACED Y+1292 FLOORBEAM IAW SRM 51-42-11 AND TRM 53-41-15.SDR DALA2015100906084Wire · brokenDURING SERVICE CHECK FOUND BROKEN WIRE LEADING TO EMERGENCY LIGHT LOCATION 9C RED EMERGENCY LIGHT. REPLACED EMERGENCY LIGHT ASSEMBLY.SDR DALA2015022401626Wire · broken1 EMERGENCY LIGHT AT ROW 2AB INOPERATIVE, REPAIRED BROKEN WIRE.SDR DALA2014120306403Wire · brokenEMERGENCY LIGHT ON SEAT 22C HAS A BROKEN WIRE: INSTALLED NEW TERMINAL END ON WIRE.SDR DALA13026603118Epsu · failedEMERGENCY LIGHTS TEST SHOWS LEFT EPSU UNIT FAULTED. REPLACED LEFT EPSU IAW AMM 33-51. SYS TESTED OK. OK FOR SERVICE.SDR DALA13015693118Wire · damaged(LP 9486407) DURING EMERGENCY LIGHT CHECK FOUND SEAT ROWS 15 AND 16 INOPERATIVE AND EPSU INTL LOAD EMER RT AT PROG AND TEST PANEL. RESET EPSU, REF TSM 33-51. REPAIRED WIRE AT SEAT 15 AND SEAT 16 REF ESPM 20-43. OP CHECK IS GOOD.SDR DALA13012303118Connector · looseSEVERAL LOCATIONS SEAT EMERGENCY PATH LIGHTS INOPERATIVE. INSPECTION EMERGENCY LIGHT PATH FOUND LOOSE CONNECTION UNDER ROW 5 SEATS A+B. RESECURED CONNECTION AS REQUIRED. OPS NORMAL MM33-52. OK FOR SERVICE.SDR DALA1205723118Sill · corrodedLEFT AFT PASSENGER DOOR SILL AT FR 66 & FR 68 HAS CORROSION. REMOVED CORROSION IAW A319 SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW A319 SRM 51-41-14 FIG 101. COMPLIED WITH ER/A 495629-14. ACCOMPLISHED PERMANENT REPAIR. LOGPAGE CREATED TO ACCOMPLISH SRI ISDR DALA1205713118Sill · corrodedRIGHT AFT PASSENGER DOOR SILL PREVIOUS REPAIR AT FR66 HAS CORROSION. REMOVED CORROSION IAW A319 SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-41-14 FIG 101. COMPLIED WITH ER/A NUMBER 495628-14 REV ORIGINAL SECTION I, PERMANENT REPAIR. LOGPAGE CRESDR DALA1204193118Floor Panel · corrodedFORWARD UTILITY FLOOR PANEL 222FF CORRODED. REPLACED PANEL 222FF ON WORKCARD 2500-6617. CORROSION DIM THICKNESS=.380" L=1.50" W=.250" D=.063".SDR DALA1205023118Floor Panel · delaminatedAFT PIT FLOOR PANEL 151ZG IS DELAMINATED AND PUNCTURED 10- X 8- AREA. FABRICATED NEW FLOOR PANEL 151ZG PER DWG 3D25-40532 DIA OF DAMAGE 10- X 8-.SDR DALA1205013118Floor Panel · delaminatedAFT PIT FLOOR PANEL 161NF IS DELAMINATED AND PUNCTURED 7- X 5- AREA. FABRICATED NEW FLOOR PANEL 161NF PER DWG 3D25-40532 DIA OF DAMAGE 7" X 5".SDR DALA1204373118Floor Panel · delaminatedFWD PIT FLOOR PANEL 132DG IS DELAMINATED AND BROKEN, 4" X 4" AREA. FABRICATED NEW FLOOR PANEL 132DG PER DWG 3D25-40532.SDR DALA1204363118Floor Panel · delaminatedAFT PIT FLOOR PANEL 151VG IS DELAMINATED AND MISSING UPPER SURFACE MATERIAL, 3- X 2- AREA. FABRICATED NEW FLOOR PANEL 151VG PER DWG 3D25-40532. DAMAGED AREA 3" X 2".SDR DALA1203913118Floor Panel · corrodedAFT UTILITY FLOOR PANEL 262FF CORRODED. DAMAGED L=2.0" W=1.0" D=.012" ORIG MAT. .032". REPLACED FLOOR PANEL 262FF.SDR DALA1203933118Floor Panel · damagedAFT UTILITY FLOOR PANEL 262EF DAMAGED 4"X 3.5". PANEL 262EF WAS FABRICATED ON TRAVELER T12/911497 IAW DRAWING 3D25-40640. STRINGER 490428 BFMSDR DALA1203923118Floor Panel · damagedAFT UTILITY FLOOR PANEL 262HG DAMAGED 3.5- X 5-. FLOOR PANEL 262HG WAS FABRICATED ON TRAVELER T12/911496 IAW DRAWING 3D25-40640. STRINGER 490428 BFMSDR DALA1203903118Sill · corrodedLT AFT PASSENGER DOOR SILL AT FR 68 HAS CORROSION AROUND NUT PLATE HOLES SSI 534147. BLENDED AREA PER A319 SRM 51-74-00 AREA 1 L=0.8' W=0.3" D=0.063 AREA 2 L=1.7" W=0.7" D=0.018. CUT OUT DAMAGE AREA IAW A319 SRM 53-41-14 FIG 201 DIMENSION CUT OUT AREA 1 L=1.SDR DALA1203893118Floor Support · corrodedFLOOR SUPPORT BEAM +Y1292 AT FR68 THROUGH FR69 HAS SEVERAL FASTENER HOLES CORRODED. BLENDED AREA IAW A319 SRM 51-74-00 L=2.80" W=1.50" D=0.070". FOUND TO BE OUT OF LIMITS IAW A319/A320 TRM 53-41-15. REMOVED AND REPLACED FLOOR SUPPORT BEAM IAW A319 SRM 51-4SDR DALA1203883118Floor Support · corrodedFLOOR SUPPORT BEAM +Y1292 BET FR66 AND FR68 HAS SEVERAL FASTENER HOLES CORRODED. BLENDED CORROSION IAW A319 SRM 51-74-00 L=2.90" W=1.0" D=0.037". FOUND TO BE OUT OF LIMITS IAW A319/A320 TRM 53-41-15. REMOVED AND REPLACED FLOOR SUPPORT BEAM. STRINGER 490428SDR DALA1203873118Floor Support · corrodedFLOOR SUPPORT BEAM +Y1292 AT FR66 HAS ONE EACH FASTENER HOLE CORRODED. BLENDED AREA IAW A319 SRM 51-74-00 L=0.60" W=0.50" D=0.069". FOUND TO BE OUT OF LIMITS IAW A319/A320 TRM 53-41-15. REMOVED AND REPLACED FLOOR SUPPORT BEAM. STRINGER 490428 BFM
Back to N318NB