As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT BEAM +Y1292 AT FR66 HAS ONE EACH FASTENER HOLE CORRODED. BLENDED AREA IAW A319 SRM 51-74-00 L=0.60" W=0.50" D=0.069". FOUND TO BE OUT OF LIMITS IAW A319/A320 TRM 53-41-15. REMOVED AND REPLACED FLOOR SUPPORT BEAM. STRINGER 490428 BFM