N319UP
Service difficulty reports · 170
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N319UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N319UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA1670519Floor Panel · damagedFLOOR PANEL POS NR 1 DAMAGED. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA1670518Floor Panel · damagedHOLE IN FLOOR PANEL. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA1670517Floor Panel · damagedFLOOR PANEL POS NR 4 CENTER HAS HOLE. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA1670516Floor Panel · damagedFLOOR PANEL POS NR1 3RD FROM RT SIDE HAS HOLE. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA1670515Floor Panel · damagedFLOOR PANEL POS NR 7R HAS HOLE. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA1670514Floor Panel · damagedFLOOR PANEL POS NR 10R HAS HOLE IN FWD END. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA1670513Floor Panel · damagedHOLE IN FLOOR PANEL POS NR 8R. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA1670512Floor Panel · damagedFLOOR PANEL POS NR 1 DAMAGED 39" AFT OF FWD END. REPAIRED IAW SRM 53-00-50-2R.SDR IPXA11669734Window · arcedINSPECTION TYPE: ETOP DIV - AT 30,000 R FWD WINDSCREEN STARTED ARCING IN LWR CTR SECTION. ARCING VERY QUICKLY PROGRESSED TO A GROWING RED EMBER WHICH THEN SPREAD ALONG LOWER LT OF WINDSCREEN, AT WHICH POINT WE SECURED POWER TO RT FWD WINDSCREEN. ARCING STOPPESDR IPXA1669634Floor Panel · damagedREF D460011 MAIN CARGO DECK FLOOR PANEL POS 11R OTBD DAMAGED. IDENTIFIED FLOOR PANEL FROM 11R OTBD AS PN146T5869-50 IAW EO B767-5320-9693- FAB A REPLACEMENT FLOOR PANEL BY CUTTING OUT NEW FLOOR PANEL FROM A402H AND MARKED INSERT LOCATION USING EXISTING FLOORSDR IPXA1669633Floor Panel · damagedMCD FLOOR PANEL POS 14R OTBD PANEL 2EA HOLES IDENTIFIED PANEL FROM POS 14R OTBD AS PN 146T5869-88 IAW EO B767-5320-969 3 FAB A REPLACEMENT PANEL BY CUTTING OUT NEW PANEL FROM A402H AND MARKED INSERT LOCATION USING EXISTING PANEL AS TEMPLATE DRILLED AND CLEANEDSDR IPXA11669615Floor Panel · damagedPOS 7R HAS A DAMAGED MAIN DECK FLOOR PANEL ON 3RD PANEL FROM RT, 2" FROM AFT EDGE AND 9" FROM OTBD EDGE HOLE MEASURE .5 INCHES IN DIAMETER. INSTALLED TEMPORARY REPAIR REF EO B767-5320-27374-B. REPAIR BY NEXT C-CHECK. REINSPECT 81 DAYS 650 FLIGHT HOURS, 305 SDR IPXA1669600Floor Panel · damagedPOSITION 7R DAMAGED MAIN DECK FLOOR PANEL. DAMAGE IS LOCATED ON 2ND FLOOR PANEL INBD FROM RT. 38 INCHES FROM AFT EDGE. DAMAGE IS 3" BY 1". MAJOR REPAIR. REMOVED FLOOR PANEL. INSTALLED FLOOR PANEL IAW MM 53-01-26-4 THRU PAR 4(8). INSTALLED TAPE TO PANEL ISDR IPXA1669599Floor Panel · damagedPOSITION 6C HAS A DAMAGED MAIN DECK FLOOR PANEL. DAMAGE LOCATED ON CENTER PANEL, 41 INCHES FROM FWD EDGE DAMAGE TO PANEL, 3 HOLES .5 INCHES IN DIAMETER. MAJOR REPAIR. REMOVED PANEL AND TRANSFERRED TO NRC 502193. INSTALLED TAPE AND COMPLETED INSTALLATION OSDR IPXA1669546Floor Panel · damagedFLOOR PANEL DAMAGED AFT EDGE CTR OF THE PANEL. FABRICATED FLOOR PANEL IAW EOB767-5320-9693-H AND REPLACED.SDR IPXA1669545Floor Panel · damagedFLOOR PANEL DAMAGED. FABLICATED FLOOR PANEL IAW EO B767-5320-9693-H AND REPLACED.SDR IPXA1669080Battery Pack · inoperativeEMERGENCY LIGHTS INOPERATIVE. R & R BATTERY PACK IAW AMM 33-51-07. OPS CHECKED OK.SDR IPXA1669070Floor Panel · damagedFLOOR PANEL MAIN DECK DAMAGED PANEL LOCATED APPROX STA 1210 TO 1270. FABRICATED NEW FLOOR PANEL IAW EO B767-5320-9693-H.SDR IPXA1669069Floor Panel · damagedFLOOR PANEL MAIN DECK DAMAGED LOCATED APPROX STA 680 TO 764. FABRICATED NEW FLOOR PANEL IAW EO-B767-5320-9693-H.SDR IPXA1665736Panel · delaminatedINSPECTION TYPE:C, RT WING INBD AILERON L/E LWR PANEL FOUND DAMAGE. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05 PAR 5A (1) FIG 5, REV 49.SDR IPXA1665755Fairing · delaminatedINSPECTION TYPE: C, RT WING INBD MAIN FLAP OTBD L/E FAIRING DELAMINATED FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-05, PAR 5A (1) FIG 5, REV 49.SDR IPXA1665734Skin · crackedINSPECTION TYPE:C, NR 2 PYLON - ACCESS PANEL 442AL CUTOUT SKIN CRACKED APP. 2 " LONG. NR 2 PYLON ACCESS PNL 442AL CUTOUT SKIN REPAIRED IAW R54-54-36993 & 767-5430-42012, CRACK LENGTH 2", CRACK STOP AT FASTENER HOLE, THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIRSDR IPXA11665647Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 6 PUNCTURES AND 7 DENT MARKS AT STA 893 TO 932 RBL 77 TO RBL 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-06.SDR IPXA11665646Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 5 PUNCTURES AND 9 DENT MARKS AT STA 1114 TO 1197+22 LBL 11 TO RBL 11. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-06.SDR IPXA11665645Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 4 PUNCTURES AND 6 DENT MARKS AT STA930 TO 975 LBL11" TO RBL11". FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED IAW AMM 53-01-06.SDR IPXA11665644Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 6 PUNCTURES AND 5 DENT MARKS AT STA731 TO 764 L77 TO L88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-06.SDR IPXA11665643Floor Panel · puncturedINSPECTION TYPE:C, MCD FLOOR PANEL FOUND 7 PUNCTURES AND 6 DENTS MARKS AT BS 412 TO 540 RBL 33 TO RBL 55. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-G AND INSTALLED IAW AMM 53-01-06.SDR IPXA1665754Skin · delaminatedINSPECTION TYPE:C, EMP - LT VERT STAB AUX SPAR TO FRONT SPAR FIXED PNL FOUND DELAMINATION. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 201, SHEET 3, REV.49. REF RS R55-31-36990, REV A AND EO B767-5530-41990-A.SDR IPXA11665655Rib · crackedINSPECTION TYPE:C, RT WING - INBD AILERON INBD HINGE BEARING SUPPORT RIB AFT FLANGE FOUND CRACKED. RT WING - INDB AILERON HINGE SUPPORT RIB AFT FLANGE REPAIRED IAW HX RS NR R57-51-36986, REV A AND EO NR B767-5740-41962-A, ORG MAT'L DIE FORGING 7075-T73 CRACK SDR IPXA11665654Stiffener · crackedINSPECTION TYPE:C, FWD CARGO COMPT WING CTR TANK FRONT SPAR VERTICAL STIFFENER AT STA 785.9, LBL 32.94, TOP AREA FOUND CRACKED. STIFFENER REPAIR IAW RS 57-10-36983 REV A & EO B767-5710-41964-A AT STA 785.9 LBL 32.94 ORG MAT'L BAC1518-749-2024T3511 CRK LENGTH SDR IPXA10661169Warning Light · illuminatedINSPECTION TYPE:E, TOP ATB DUE TO FWD EQUIPT OVERHEAT. RAN CHECK LIST & FWD EQUIPT OVERHEAT EICAS MESSAGE CAME BACK ON. THEN GOT R FMC FAIL. PERFORMED T/S IAW FIM 21-58-00 FIG 115. PERFORMED T/S IAW FIM 28-58- 00, FIG 105. ALL CHECKS PASS OK. CHECKED CONICALSDR IPXA09657960Floor Panel · damagedINSPECTION TYPE:N/A DAMAGE TO FLOOR PANEL AT 7 RT REF D412512 EDGE BAND DAMAGE. REPLACED FLOOR PANEL PER EO B767-5320-9693-F.SDR IPXA09657123Floor Panel · damagedINSPECTION TYPE:N/A MAIN CARGO DECK FLOOR PANEL POS 7R DAMAGED. REPAIRED PER EO B767-5320-34683-A.SDR IPXA09657122Floor Panel · damagedINSPECTION TYPE:N/A MAIN CARGO DECK FLOOR PANEL POS 6 DAMAGED. REPAIRED PER EO B767-5320-34684-A.SDR IPXA09655142Fairing · delaminatedINSPECTION TYPE:C LT WING I/B MAIN FLAP O/B LEADING EDGE FAIRING DELAMINATION. COMPOSITE WET LAY UP REPAIR CARRIED OUT AS PER SRM 51-70-03 PARA 5A (1) FIG 5 REV 43.SDR IPXA09655175Stiffener · crackedINSPECTION TYPE:C WING CENTER SECTION FWD BULKHEAD VERTICAL STIFFENER FOUND CRACKED JUST AT RBL 10, WL 195. CRACK 3.75 INCH LENGTH. WING CTR SECTION FWD BULKHEAD STA 785.9 WL 195 RBL 10 VERTICAL STIFFENER REPAIRED AS PER HX RS R57-11-36287 REV B AND UPS EO BSDR IPXA09655150Stiffener · crackedINSPECTION TYPE:6C MEC - MAIN DECK FLOOR SUPPORT ATT STIFFENER FOUND CRACKED JUST AT STA 246 RBL 10 - RBL 11. MEC - MAIN DECK FLOOR SUPPORT ATT STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43 JUST AT STA 246 RBL 10 - RBL 11.SDR IPXA09655138Panel · delaminatedINSPECTION TYPE:C LT WING I/B MAIN FLAP LWR PNL 555EB FOUND DELAMINATED. METAL HOT BOND REPAIR PERFORMED AS PER SRM 51-70-10 REPAIR 4 FIG 201 REV 43.SDR IPXA09655136Stiffener · deformedINSPECTION TYPE:C BULK CARGO - STA 1480 FLOOR PANEL SUPPORT STIFFENER DEFORMED AT LBL 9. BULK CARGO STA 1480 FLOOR PANEL SUPPORT STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43 JUST AT LBL 9.SDR IPXA09655135Stiffener · deformedINSPECTION TYPE:C BULK CARGO STA 1480 FLOOR PANEL SUPPORT STIFFENER DEFORMED AT RBL 9. BULK CARGO STA 1480 FLOOR PANEL SUPPORT STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43 JUST AT RBL 9.SDR IPXA09655134Stiffener · deformedINSPECTION TYPE:C BULK CARGO STA 1461 FLOOR PANEL SUPPORT STIFFENER DEFORMED AT RBL 9. BULK CARGO STA 1461 FLOOR PANEL SUPPORT STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43 JUST AT RBL 9.SDR IPXA09655133Stiffener · deformedINSPECTION TYPE:C BULK CARGO - STA 1502 FLOOR PANEL SUPPORT STIFFENER DEFORMED AT RBL 9. BULK CARGO STA 1502 FLOOR PANEL SUPPORT STIFFENER REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43 JUST AT RBL 9.SDR IPXA09655159Attach Fitting · crackedINSPECTION TYPE:C MEC - BS 246 CABIN FLOORBEAM AFT FACE ATT CLIP CRACKED AT LBL 50 (CRACK 1 INCH LENGTH). MEC - BS 246 CABIN FLOORBEAM AFT FACE ATT CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43 JUST AT LBL 50.SDR IPXA09655120Floorbeam · crackedINSPECTION TYPE:C MEC STA 246 CABIN FLOORBEAM FWD FACE ALTERNATE L/G ELECT ACT SUPPORT ANGLE CRACKED AT LBL 25 (CRACK 0.625 INCH LENGTH). MEC STA 246 CABIN FLOORBEAM FWD FACE ALTERNATE L/G ELECT ACT SUPPORT ANGLE REPLACED AS PER SRM 51-10-02 AND INSTALLED AS SDR IPXA09655176Fitting · crackedINSPECTION TYPE:C LT WING - L/E LES 675 FIXED FAIRING SUPPORT AFT FRONT SPAR CLIP FOUND CRACK. CRACK 0.75 INCH LENGTH. LT WING - L/E LES 675 FIXED FAIRING SUPPORT AFT FRONT SPAR CLIP REPLACED AS PER SRM 51-10-02 AND INSTALLED AS PER SRM 51-40-02 REV 43.SDR IPXA09655158Hinge Fitting · crackedINSPECTION TYPE:C LT WING - I/B MAIN FLAP I/B AFT FLAP HINGE FITTING FOUND CRACKED. CRACK 1.25 INCH AND 1.5 INCH LENGTH. LT WING I/B MAIN FLAP I/B AFT FLAP HINGE FITTING REPAIRED AS PER SRM 57-53-02-2R1 FIG 201 SHT 1 TO 5 REV 43. THIS IS CLASSIFIED AS A MAJSDR IPXA09655157Support · crackedINSPECTION TYPE:C FWD CARGO COMPT STA 480.75 DOOR SILL BALLMAT PANEL FOUND CRACKED. CRACK 3.75 INCH LENGTH. FWD CARGO COMPT STA 480.75 DOOR SILL BALLMAT PANEL SUPPORT REPAIRED AS PER HX RS R53-00-36286 REV B AND UPS EO B767-5300-32787-A.SDR IPXA09655141Panel · delaminatedINSPECTION TYPE:C RT WING NR 7 SLAT LWR CLOSURE PANEL I/B AREA THE EXISTING REPAIR (REF SURVEY SEQ 319-W4-01) DELAMINATION. COMPOSITE WET LAY UP REPAIR CARRIED OUT AS PER SRM 51-70-17 PARA 4H FIG 19 REV 43.SDR IPXA09655140Wedge · delaminatedINSPECTION TYPE:C LT WING O/B TRAILING EDGE FLAP LOWER TRAILING EDGE MID AREA THE EXISTING REPAIR PATCH (REF SURVEY SEQ 319-W3-03) DELAMINATION. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-07 PARA 5A (1) FIG 9 REV 43.SDR IPXA09655139Wedge · delaminatedINSPECTION TYPE:C LT WING O/B TRAILING EDGE FLAP LOWER TRAILING EDGE I/B AREA THE EXISTING REPAIR (REF SURVEY SEQ 319-W3-04) DELAMINATION. COMPOSITE HOT BOND REPAIR CARRIED OUT AS PER SRM 51-70-07 PARA 5A (1) FIG 9 REV 43.