INSPECTION TYPE:C, EMP - LT VERT STAB AUX SPAR TO FRONT SPAR FIXED PNL FOUND DELAMINATION. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 201, SHEET 3, REV.49. REF RS R55-31-36990, REV A AND EO B767-5530-41990-A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, EMP - LT VERT STAB AUX SPAR TO FRONT SPAR FIXED PNL FOUND DELAMINATION. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 201, SHEET 3, REV.49. REF RS R55-31-36990, REV A AND EO B767-5530-41990-A.