N325NB
Service difficulty reports · 138
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N325NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N325NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2018070304419Frame · crackedCRACK INDICATION ON FRAME 20 IN HOLE 5 & HOLE 6 RT SIDE UPPER CORNER OF DOOR FRAME IN PASSENGER CABIN. REPLACED FRAME 20 RT SIDE AND FASTENERS AS PER SRM 51-72-11 AND ERA 569173-14 REV ORIGINAL.SDR DALA2018062604268Floorbeam · corrodedCORROSION ON FLOORBEAM - Y1162 BETWEEN FR68 TO FR69, AFT GALLEY AREA. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-72-11 AND DWG D53472780.SDR DALA2018062004110Frame Splice · crackedCRACK SPLICE CONNECTION ON FR68 BTW STR 23L TO STR 24L AT AFT GALLEY AREA, REPLACED SPLICE CONNECTION ON FR68 BTW STR 23L TO STR 24L AT AFT GALLEY AREA AS PER SRM 51-42-11 AND DRAWING D5347108720300.SDR DALA2018061904109Floorbeam · corrodedCORROSION FLOORBEAM +Y1162 BTW FR68 TO FR69 AT AFT GALLEY AREA. REPLACED FLOORBEAM +Y1162 BTW FR68 TO FR69 AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DWG D53472780.SDR DALA2018061904108Floorbeam · corrodedCORROSION FLOORBEAM -Y464 LOC BTW FR 64 TO FR67 AT AFT GALLEY AREA. REPLACED FLOORBEAM -Y465 LOC BTW FR64 TO FR67 AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DWG D53472816.SDR DALA2018061904107Floorbeam · corrodedCORROSION FLOORBEAM AT LEVEL +Y1130 BTW FR 66+6INCH TO FR68 AT AFT GALLEY AREA. REPLACED FLOORBEAM AT LEVEL +Y1130 BTW FR 66+6" TO FR 68 AT AFT GALLEY AREA ASPER SRM 51-72-11 AND DRAWING D53472172-20400.SDR DALA2018061904106Floorbeam · corrodedCORROSION FLOORBEAM Y503.2 LOC BTW FR 12 TO FR 16 AT FWD GALLEY AREA. REPLACED FLOORBEAM -Y503.2 LOC BTW FR12 TO FR16 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112826.SDR DALA2018061904105Floorbeam · corrodedCORROSION FLOORBEAM +Y765 LOC BTW FR 12 TO FR 24 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y765 LOC BTW FR12 TO FR 24 AT GALLEY AREA FLOOR STRUCTURE AS PER SRM 51-72-11 AND DWG 53112812.SDR DALA2018061904104Floorbeam · corrodedCORROSION FLOORBEAM +Y1292 LOC FR64 TO FR 66 AT AFT GALLEY AREA. REPLACED FLOORBEAM +Y1292 LOC FR64 TO FR66 AT AFT GALLEY AREA AS PER SRM 51-72-11.SDR DALA2018061804102Skin · dentedDENT EXTERNAL SKIN LOC BTW FR 12 TO FR 13 AND 10" ABOVE UPPER SIDE STR RT ON LOWER FUSELAGE. PERFORMED PERMANENT REPAIR EXTERNAL SKIN LOC BTW FR 12 TO FR 13 AND 10" ABOVE UPPER SIDE STR RT ON LOWER FUSELAGE AS PER SRM 53-00-11-300-029.SDR DALA2018061804101Floorbeam · corrodedCORROSION FLOORBEAM -Y1379.5 LOC BTW FR12 TO FR16 AT FWD GALLEY AREA. REPLACED FLOORBEAM -Y1379.5 LOC BTW FR12 TO FR16 AT FWD GALLEY AREA ASPER SRM 51-72-11 AND DRAWING D53110984.SDR DALA2018061804103Floorbeam · corrodedCORROSION FLOORBEAM +Y765 BTW FR66 TO FR70 AT AFT GALLEY AREA. REPLACED FLOORBEAM +Y765 BTW FR66 TO FR70 AT AFT GALLEY AREA SRM 51-72-11 AND DRAWING D53112826.SDR DALA2018061704100Floorbeam · corrodedCORROSION FLOORBEAM -Y254 LEVEL FR16 AT FWD GALLEY AREA. REPLACED FLOORBEAM -Y254 LOC. BTW FR12 TO FR24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DRAWING D53110920.SDR DALA2018061704099Floorbeam · corrodedCORROSION FLOORBEAM +Y254 LOC BTW FR 12 TO FR 24 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y254 LOC BTW FR12 TO FR24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112816.SDR DALA2018061704098Floorbeam · corrodedCORROSION FLOORBEAM -Y81 LOC BTW FR12 TO FR16 AT FWD GALLEY AREA. REPLACED FLOORBEAM -Y81 LOC BTW FR12 TO FR16 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112828.SDR DALA2018061704097Floorbeam · corrodedCORROSION FLOORBEAM -Y765 LOC BTW FR 12 TO FR 24 AT FWD GALLEY AREA. REPLACED FLOORBEAM -Y765 LOC BTW FR12 TO FR24 AT FWD GALLEY AREA AS PER SRM 51-72-11, AND DWG D53112812.SDR DALA2018061704096Floorbeam · corrodedCORROSION FLOORBEAM -Y1292 LOC BTW FR12 TO FR24 AT FWD GALLEY AREA. REPLACED FLOORBEAM -Y1292 LOC. BTW FR12 TO FR24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DRAWING D53112812.SDR DALA2018061704095Fitting · corrodedCORROSION CENTER FITTING LOC BTW FR16 TO FR 20 LEVEL STR 23R AT FWD GALLEY AREA. REPLACED CENTER FITTING LOC BTW FR 16 TO FR20 AT LEVEL STR 23R AT FWD GALLEY AREA.SDR DALA2018061704094Door Sill · corrodedCORROSION LOWER SILL FR66 TO FR68 ST LEVEL STR 23L AT AFT GALLEY AREA, REPLACED LOWER SILL LOC AT LEVEL STR 23L BTW FR66 TO FR68 AFT GALLEY AREA FLOOR STRUCTURE ASPER SRM 51-72-11, SRM 51-42-11, DRW D53480505.SDR DALA2018061704093Floorbeam · corrodedCORROSION FLOORBEAM +Y1292 LOC BTW FR12 TO FR24 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y1292 LOC BTW FR12 TO FR24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112812.SDR DALA2018061414010Floor Support · corrodedCORROSION FOUND ON THE FLOOR SUPPORT, -Y765 BETWEEN FRAMES 66 TO 70. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DWG D53472780.SDR DALA2018060803907Web · corrodedCORROSION WEB AT LEVEL STRINGER 23L AT AFT GALLEY AREA BETWEEN FRAME 69 TO FRAME 70, REPLACED WEB AND FASTENER AT LEVEL OF STRINGER 23L AT AFT GALLEY AREA BETWEEN FRAME 69 TO FRAME 70 ASPER SRM 51-42-11, 51-72-11 AND DRAWING NR D53474180.SDR DALA2018032601922Stringer · corrodedCORROSION FOUND AFT ATG 4 ANTENNA ON AN EXISTING STRINGER REPAIR, REPAIRED THE STRINGER IAW SRM 53-00-13-300-002, FIG 20102.SDR DALA2016092706864Wire · out of positionR1 EMERGENCY EXIT LIGHT REMAINS ON WHEN EMERGENCY EXIT LIGHT SWITCH IS IN THE ARMED POSITION. FOUND WIRE 1741 AT TERMINAL BLOCK 2749VT INSTALLED IN WRONG LOCATION, BLOCK 29, POSITION G. MOVED TO CORRECT LOCATION BLOCK 30, POSITION H.SDR DALA2016090306796Box Beam · crackedCRACK INDICATION AT AFT FASTENER HOLE SIDE BOX BEAM AT FRAME 43, REPAIRED IAW ERA 549762-14.SDR DALA2016090306788Box Beam · crackedCRACK INDICATION AT AFT FASTENER HOLE SIDE BOX BEAM AT FRAME 43 RT, PERMANENT REPAIR PER ERA 549739-14.SDR DALA1800413125Box Beam · crackedCENTER FUSELAGE LT SIDE BOX BEAM AT FRAMES 43, Y1650, CRACK INDICATION, IAW ER/A 549762-14.SDR DALA2016020300836Wire · damagedROW 13, EMERGENCY EXIT LIGHT INOPERATIVE, REPAIRED WIRING.SDR DALA2016020300835Connector · inoperativeROW 11, EMERGENCY EXIT LIGHT INOPERATIVE, INSTALLED NEW CONNECTOR FOR EMERGENCY EXIT ROW LIGHT 11.SDR DALA2016011400310Battery Pack · failedEPSU BATTERY FWD LT MESSAGE, REPLACED BATTERY PACK ON PSU 10WL.SDR DALA2016112509223Stringer · corrodedCORROSION FOUND ON STRINGER 43L BETWEEN FRAMES 59 AND 60. REMOVED CORROSION, TREATED AND PRIMED. A REPAIR WAS FABRICATED, AND INSTALLED IAW SRM.SDR DALA2016112509222Stringer · corrodedCORROSION FOUND ON STRINGER 42L BETWEEN FRAMES 59 AND 60. REMOVED CORROSION, TREATED, PRIMED. A REPAIR WAS FABRICATED, AND INSTALLED IAW SRM.SDR DALA13052083125Power Supply · inoperativeCABIN EMERGENCY LIGHTS, AND TWO AFT EXIT SIGNS. THREE CEILING EMERGENCY LIGHTS NEAR ASSOCIATED INOPERATIVE EVACUATION LIGHTS INOPERATIVE ON EMERGENCY POWER. LIGHTS FLASH FOR A SECOND WHEN ON BATTERY POWER. ALL LIGHTS WORK NORMAL WHEN ACFT ON NORMAL POWER. SDR DALA13005723125Epsu · faultedLT EPSU BATTERY FAULT R & R LT EPSU BATTERY IAW AMM 33-51-38 PB 401. OPS CHECKED GOOD.SDR DALA13004093125Wire · disconnectedEMERGENCY LIGHTS AT DOOR 2R INOPERATIVE. FOUND WIRES DISCONNECTED. RECONNECTED AND OPS CHECKED OK.SDR DALA13004083125Battery Pack · failedEMERGENCY LIGHT BATTERY PACK AT DOOR 1L FAILS TEST. R & R BATTERY PACK IAW AMM 33-51-38. OPS CHECKED OK.SDR DALA12016843125Wire · brokenSEAT 4 EMERGENCY LIGHT INOPERATIVE. FOUND BROKEN WIRE AND REPAIRED. OPS CHECK NORMAL.SDR DALA12013133125Wire · brokenEMERGENCY EXIT PATHWAY LIGHT INOPERATIVE AT SEAT 12 ABC. FOUND WIRE BROKEN AT WHITE CONNECTOR UNDER AFT SEAT SUPPORT BAR. CONNECTED CONNECTOR. OPS CHECKED GOOD.SDR DALA12007543125Wire · damagedEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE AT LOCATION 06C. SECURED WIRING. CHECKED NORMAL. OK FOR SERVICE.SDR DALA12007533125Wire · damagedEMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE AT LOCATION 06C. SECURED WIRING. CHECKED NORMAL. OK FOR SERVICE.SDR DALA12006013125Panel · damagedFORWARD CARGO SLOPE PANEL 132EG IS DAMAGED. SLOPE PANEL FABRICATED NEW IAW SRM 53-02-00 FIG 209.SDR DALA12006003125Panel · damagedFORWARD CARGO SLOPE PANEL 131DG IS DAMAGED. SLOPE PANEL FABRICATED NEW IAW SRM 53-02-00 FIG 209.SDR DALA12005993125Panel · puncturedFORWARD CARGO SLOPE PANEL 132DG SKIN PUNCTURES 3 X 3 INCHES. SLOPE PANEL FABRICATED NEW IAW SRM 53-02-00 FIG 209.SDR DALA12005983125Panel · damagedAFT CARGO SLOPE PANEL 151HE DAMAGED 1 INCHES BY 1 INCH. SLOPE PANEL FABRICATED NEW IAW SRM 53-02-00 FIG 209.SDR DALA12005973125Panel · damagedAFT CARGO SLOPE PANEL 151GE DAMAGED 1.5 INCHES BY 1 INCH. SLOPE PANEL FABRICATED NEW IAW SRM 53-02-00 FIG 209.SDR DALA12005963125Floor Panel · puncturedFORWARD CARGO FLOOR PANEL 131AF MULTIPLE PUNCTURES. FLOOR PANEL FABRICATED NEW IAW SRM 53-02-00 FIG 209.SDR DALA12005953125Panel · gougedFWD CARGO SLOPE PANEL 131CF SKIN GOUGES 2 BY 2 INCHES. SLOPE PANEL FABRICATED NEW IAW SRM 53-02-00 FIG 209.SDR DALA12005943125Panel · puncturedAFT CARGO SLOPE PANEL 152UG MULTIPLE PUNCTURES. FABRICATED NEW PANEL PER DWG 3D25-40532 AS PER SRM 53-02-00 FIG 209.SDR DALA12005933125Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151CE DELAMINATED 3 INCH BY 3 INCHES. FABRICATED NEW FLOOR PANEL PER DWG 3D25-40532 IAW SRM 53-02-00 FIG 209.SDR DALA12005923125Panel · puncturedAFT CARGO SLOPE PANEL 152TG MULTIPLE PUNCTURES. FABRICATED NEW PANEL IAW SRM 53-02-00 FIG 209 DWG NR 3D25-40532.
Back to N325NB