What was found
CORROSION LOWER SILL FR66 TO FR68 ST LEVEL STR 23L AT AFT GALLEY AREA, REPLACED LOWER SILL LOC AT LEVEL STR 23L BTW FR66 TO FR68 AFT GALLEY AREA FLOOR STRUCTURE ASPER SRM 51-72-11, SRM 51-42-11, DRW D53480505.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION LOWER SILL FR66 TO FR68 ST LEVEL STR 23L AT AFT GALLEY AREA, REPLACED LOWER SILL LOC AT LEVEL STR 23L BTW FR66 TO FR68 AFT GALLEY AREA FLOOR STRUCTURE ASPER SRM 51-72-11, SRM 51-42-11, DRW D53480505.