N333NB
Service difficulty reports · 224
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N333NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N333NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2024090908809Window Frame · crackedSHIP 3133 FUSELAGE FR4 RH LATERAL WINDOW FRAME UPPER ATTACHMENT STIFFENER CRACK. CORRECTIVE ACTION: REPAIRED PER ERA 575078-14AD. (0542614)SDR DALA2024090208629Bushing · corrodedSHIP 3133 CORROSION ATTACH FITTING BUSHING ON RUDDER HINGE #5 (2EA). CORRECTIVE ACTION: REPLACE BUSHINGS (2EA) ON HINGE FITTING # 5 RUDDER, AS PER A319 SRM 51-72-12-911-002. (0532298)SDR DALA2024090208628Bushing · corrodedSHIP 3133 CORROSION ATTACH FITTING BUSHING MIDDLE SERVO CONTROL ON RUDDER (2 EA). CORRECTIVE ACTION: REPLACED BUSHINGS (2EA) ATTACH FITTING MIDDLE SERVO CONTROL ON RUDDER AS PER A319 SRM 51-72-1-911-002. (0532297)SDR DALA2024090208627Bushing · corrodedSHIP 3133 CORROSION ATTACH FITTING BUSHING ON RUDDER HINGE #1 (2EA). CORRECTIVE ACTION: REPLACED BUSHINGS (2EA) ON HINGE FITTING # 1 RUDDER, AS PER A319 SRM 51-72-12-911-002. (0532296)SDR DALA2024090208626Bushing · corrodedSHIP 3133 CORROSION ON BUSHING ATTACHMENT HINGE FITTING OUTBOARD ACTUATOR (1E/A) OF THE AILERON RH. CORRECTIVE ACTION: REPLACED BUSHING (1 EA) ON I/B LUG ON ATTACHMENT HINGE FITTING O /B ACTUATOR OF RH AILERON AS PER A319 SRM 51-72-12-911-002. (0532323)SDR DALA2024090208625Bushing · corrodedSHIP 3133 CORROSION ON BUSHING ATTACHMENT HINGE FITTING #3 (1E/A) OF THE RH AILERON. CORRECTIVE ACTION: REPLACED BUSHING (1 EA) ON O/B LUG ON ATTACH FITTING #3 RH AILERON AS PER AIRBUS CMM 57-61-21. (0532315)SDR DALA2024090208624Bushing · corrodedSHIP 3133 CORROSION ON BUSHING ATTACHMENT HINGE FITTING #4 (2E/A) OF THE AILERON LH. CORRECTIVE ACTION: REPLACED BUSHINGS (2 EA) ON ATTACH FITTING 4 LH AILERON AS PER AIRBUS CMM 57-61-21. (0532313)SDR DALA2024090208623Bushing · corrodedSHIP 3133 CORROSION ON BUSHING ATTACHMENT HINGE FITTING INBOARD ACTUATOR (1E/A). CORRECTIVE ACTION: REPLACED BUSHINGS (1 EA) ON I/B LUG ON ATTACHMENT HINGE FITTING I/B ACTUATOR AT LH AILERON. AS PER AIRBUS CMM 57-61-21. (0532310)SDR DALA2024090208622Bushing · corrodedSHIP 3133 CORROSION ON BUSHING ATTACHMENT HINGE FITTING #2 ON LH AILERON. CORRECTIVE ACTION: REPLACED BUSHINGS (1 EA) I/B LUG ON ATTACH FITTING #2 LH AILERON AS PER AIRBUS CMM 57-61-21. (0532306)SDR DALA2024090208621Bushing · corrodedSHIP 3133 CORROSION ON BUSHING ATTACHMENT HINGE FITTING #1 E/A ON L/H AILERON. CORRECTIVE ACTION: REPLACED BUSHINGS (1 EA) ON I/B LUG ON ATTACH FITTING #1 LH AILERON. AS PER AIRBUS CMM 57-61-21. (0532303)SDR DALA2024090208618Floor Support · corrodedSHIP 3133 CORROSION FLOOR BEAM Y1162 LOCATED BTW FR 68 TO FR 69 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM Y 1162 LOCATED BTW FR 68 TO FR 69 AFT GALLEY AREA AS PER A319 SRM 51-42-11 AND SRM 51-72-11. (0531380)SDR DALA2024090208632Hinge Fitting · corrodedSHIP 3133 CORROSION ON BUSHING ATTACHMENT HINGE FITTING #3 (1E/A) OF THE LH AILERON. CORRECTIVE ACTION: REPLACED BUSHINGS (1 EA) ON O/B LUG ON ATTACH FITTING #3 LH AILERON AS PER AIRBUS CMM 57-61-21. (0532302)SDR DALA2024082608462Bushing · corrodedSHIP 3133 CORROSION ATTACH FITTING BUSHING ON RUDDER HINGE 4 (1EA). CORRECTIVE ACTION: REPLACED BUSHINGS (1 EA) ON HINGE FITTING # 4 RUDDER, AS PER A319 SRM 51-72-12-911-002. (0521087)SDR DALA2024082608461Bushing · corrodedCORROSION ATTACH FITTING BUSHING ON RUDDER HINGE 7. REPLACED BUSHINGS (2EA) ON HINGE FITTING # 7 RUDDER, AS PER A319 SRM 51-72-12-911-002.SDR DALA2024082608460Bushing · corrodedCORROSION ATTACH FITTING BUSHING ON RUDDER HINGE 3. REPLACED BUSHINGS (2EA) ON HINGE FITTING # 3 RUDDER, AS PER A319 SRM 51-72-12-911-002.SDR DALA2024040404059Light · dimSHIP 3133 FLOOR PROXIMITY EMERGENCY ESCAPE LIGHT LED AT 20D HALFWAY ILLUMINATED. CORRECTIVE ACTION: R/R CABIN EMERGENCY LIGHT IAW A319 AMM 33-51. OPS CHECK GOOD. (5538728)SDR DALA2024032203685Apu · unknownSHIP 3133 - ATB - RETURNED TO SLC DUE TO AN APU EMERGENCY SHUTDOWN MESSAGE AFTER TAKEOFF. THE APU WAS NOT IN USE AT THE TIME OF THE MESSAGE. JAC OPERATIONS SHOWED NO AIR START CART AVAILABLE ON THEIR OPS PAGE. RETURNED TO SLC. CORRECTIVE ACTION: PERFORMED APU SDR DALA2023013000731Warning Message · illuminatedATB DUE TO AN AIR ENG 1 BLEED ABNORMAL PRESSURE FAULT MESSAGE. MESSAGE REQUIRES AIRCRAFT TO AVOID ICING CONDITIONS. R & R NR 1 TLT (10HA1).SDR DALA2022070504639None · noneSHIP 3133 - OXYGEN PANEL MASK DEPLOYED LOCATIONS:28A . CORRECTIVE ACTION: STOWED MASKS AT ROW 29ABC PER AA319 AMM 35-21-43.(2305006)SDR DALA2022070504636None · noneSHIP 3133 - WHILE WORKING AA#2527-01041-02 FOUND 3 BA DID NOT OPEN OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 3 BA PER A319 AMM TASK 35-21 -43.(8634832)SDR DALA2022070504634None · noneSHIP 3133 - WHILE WORKING AA # 2527-01041-02 FOUND 26 FED DID NOT OPEN PSU OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 26 FED PER A319 AMM TASK 35- 21-43.(8634837)SDR DALA2022070504633None · noneSHIP 3133 - WHILE WORKING AA # 2527-01041-02 FOUND 22 CBA DID NOT OPEN PSU OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 22 CBA PER A319 AMM TASK 35- 21-43.(8634836)SDR DALA2022070504632None · noneSHIP 3133 - WHILE WORKING AA# 2527-01041-02 FOUND 17 FED DID NOT OPEN PSU OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 17 FED PER A319 AMM TASK 35- 21-43.(8634835)SDR DALA2022070504631None · noneSHIP 3133 - WHILE WORKING AA# 2527-01041-02 FOUND 16 CBA DID NOT OPEN PSU OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 16 CBA PER A319 AMM TASK 35- 21-43.(8634834)SDR DALA2022070504630None · noneSHIP 3133 - WHILE WORKING AA#2527-01041-02 FOUND 12 FED DID NOT OPEN OXY PANEL. CORRECTIVE ACTION: REPACKED PSU PANEL 12 FED PER A319 AMM TASK 35-21 -43.(8634833)SDR DALA2022041902680None · noneSHIP 3133 - DIV - TO JFK WITH #2 ENG ANTI ICE VALVE CLOSED MESSAGE. COULD NOT CONTINUE TO PVD DUE TO ICING CONDITIONS. CORRECTIVE ACTION: DEFERRED VALVE IN OPEN POSITIONPER MEL 30-21-01D AND CONTINUED.(8744756)SDR DALA2022040702400None · noneSHIP 3133 - DURING SVC CHECK FOUND L1 DOOR ASSIST PRESSURE LOW. CORRECTIVE ACTION: SERVICED DOOR ASSIST BOTTLE IAW A319 AMM 52-10.(8744722)SDR DALA2021100706145Oxygen Mask · failedSHIP 3133 - SEATS 17DEF INOP DUE TO PAX OXYGEN PANEL INOP. CORRECTIVE ACTION: REPLACED O2 PANEL ASSY PER CMM 25-28-02.(7781018)SDR DALA2021093005906None · noneSHIP 3133 - FWD CABIN EXIT LOCATION LIGHT (50WL) LENS IS INCORRECT. CORRECTIVE ACTION: REMOVED AND REPLACED FWD CABIN EXIT SIGN. REF A319 IPC 33-51(7781014)SDR DALA2021081604713Frame · crackedSHIP 3133 - CRACK INDICATION NOTED ON RH FR 42 TI ANGLE CONNECTION WEBN SIDE SECOND HOLE FROM THE BOTTOM AT THE 9 O CLOCK POSITION. CORRECTIVE ACTION: REPAIRED SHEAR PLATE AT FR 42 AT RH SIDE IAW ER/A 593285-14AD REV ORIGINAL.(1913007)SDR DALA2021081204644Angle · crackedSHIP 3133 - DURING TASK CARD INSPECTION FOUND RH AFT TI ANGLE CRACKED LOWER INBD FLANGE BETWEEN FASTENERS AD 19-08-07. CORRECTIVE ACTION: ACCOMPLISHED REMOVE AND REPLACE OF 4 EA TI-ANGLE CONNECTIONS ON KEEL BEAM AT FR 40-42 RH AND LH IAW W/C 5353.(1906972)SDR DALA2021041202124Cylinder · low pressureSHIP 3133 - L1 DOOR EMERGENCY OPERATING CYLINDER/ACCUMULATOR PRESSURE LOW. CORRECTIVE ACTION: SERVICED L1 DOOR EMERGENCY OPERATING CYLINDER/ ACCUMULATOR PER A320 AMM TASK. (7388603)SDR DALA2021021600838Psu · no testSHIP 3133 DURING TEST FA AFT CENTER PSU OXYGEN PANEL FAILED TO OPEN. CORRECTIVE ACTION: REPLACED AFT CABIN FLT ATTENDANT O2 CONTAINER PER A319 M/M 35-21. OPS CK GOOD. (7565804)SDR DALA2021021200827Control Unit · faultedSHIP 3133 - GEAR/DE - ON APPROACH DID GO AROUND DUE TO LGCIU 1 FAULT. HAD 3 GREEN ON WHEEL PAGE. CORRECTIVE ACTION: TROUBLESHOT PER A319 TSM 32-21 FOUND 26GA FAULTY. REPLACED, SEALED, AND APPLIED CORROSION PREVENTION PER A319 AMM 32-21. BITE CHECKS GOOD.SDR DALA2020121704129Oxygen Mask · no testSEAT 29ABC O2 MASK DIDN`T DEPLOY PERFORMING O2 MASK TASK CARD 2527-01041-02. CORRECTIVE ACTION: R & R PASSENGER OXYGEN PANEL UNIT, REF A319 AMM 25-25. REMOVED OXYGEN GENERATOR FROM OLD OXYGEN PANEL & REINSTALLED IT ON NEW OXYGEN PANEL, REF A319 35-21. OPERASDR DALA2020100603296Oxygen Mask · no testDURING ACCOMPLISHMENT OF AMDS WORK CARD THE AFT LEFT FLIGHT ATTENDANT OXYGEN MASK FAILED TO OPEN DURING STEP 1. CORRECTIVE ACTION: DOOR WAS RUBBING ON TRIM. ADJUSTED BOX, PER A319 AMM 35-21. OPERATIONS CK GOOD ASSOCIATED AA 2527-01041.SDR DALA2020100603295Oxygen Mask · no testDURING ACCOMPLISHMENT OF AMDS WORK CARD THE PSU OXYGEN MASK DOOR AT SEATS LT 1, 14, 24, 29 AND RT 1, 17, 20, 28 FAILED TO OPEN DURING STEP 1 TEST. CORRECTIVE ACTION: AMDS WORK CARD STEP 2, 3, AND 6 THROUGH 12 WERE ACCOMPLISHED WHICH RESTORED AND VALIDATED PROSDR DALA2020100503285Fitting · inoperativeDURING 2A CHECK FOUND INOP AFT GIRT BAR FITTING ON L1 DOOR. CORRECTIVE ACTION: R & R GIRT BAR FITTING, IAW A320 AMM/52-11-31. OPERATIONS CHECK GOOD.SDR DALA2020071402583Unknown · smokeAFTER COMPLETING SHUTDOWN CHECKLIST NOTED ELECTRICAL SMELL AND SLIGHT SMOKE IN FLIGHT DECK. FIRST INDICATION WAS FROM BEHIND CPT SEAT AND SECOND INSTANCE BY CAPTAINS FORWARD WINDSCREEN. FO NOTICED SLIGHT ELECTRICAL SMOKE SMELL BY AVIONICS BAY ON WALK AROUND.SDR DALA2019120307033Control Valve · malfunctionedSHIP 3133 - ATO - AT 20 KNOTS DUE TO TAKEOFF CONFIGURATION WARNING WITH ECAM MESSAGE "PARKING BRAKE SET" WITH THE PARKING BRAKE SELECTED OFF. CORRECTIVE ACTION: REPLACED THE PARKING BRAKE CONTROL VALVE.SDR DALA2019100405710Sdac · malfunctionedDIVERTED DUE TO FLIGHT CREW REPORTING THAT THEY CANNOT GET THE USEABLE FUEL TO TRANSFER OUT OF THE OUTER FUEL TANKS. WING OUTER VALVE INDICATIONS SHOWED AMBER AND CLOSED. FALSE INDICATIONS ATTRIBUTED TO SDAC 1 DUE TO OTHER ERRONEOUS FAULTS. FUEL TRANSFER IS NOSDR DALA2019040702267Power Supply · inoperativeWHILE WORKING L1 SLIDE CHANGE WITH W/C 2561-4003LF, RECEIVED " EPSU INT LOAD FWD L" FAULT DURING OPERATIONAL CHECK OF THE ESCAPE -FACILITIES, REPLACED EPSU (10WL)SDR DALA2019022731269Skin · damagedCONFIRM DT EVALUATION FOR POSSIBLE FCS REPAIR EXTERNAL SKIN BTW FR 22 TO FR 23 STR 43L TO STR 42R ON LOWER FUSELAGE. PERFORMED REPAIR INSTRUCTIONS SECTION I LOC ON EXTERNAL SKIN BTW FR 22 TO FR 23 STR 43L TO STR 42R ON LOWER FUSELAGE AS PER ER/A 575263-14.SDR DALA2019022211121Floor Support · corrodedCORROSION FLOOR BEAM LOC FR66 TO FR68 LH SIDE AT AFT GALLEY AREA, REPLACED FLOOR BEAM LOC. FR 66 TO FR 68 LH SIDE AFT GALLEY AREA PER SRM A319 51-72-11 AND DWG #D53472780SDR DALA201902221120Structure · corrodedCORROSION LOWER SILL LOC FR66 TO FR68 STR23 LH SIDE AT AFT GALLEY AREA, REPLACED LOWER SILL LOC. FR.66 TO FR 68 STR. 23 LH SIDE AT AFT GALLEY AREA PER A319 SRM 51-42-11 AND DWG D53480505SDR DALA201902221119Floor Support · corrodedCORROSION FLOOR BEAM LOC FR64 TO FR66 + Y1292 AT AFT GALLEY, REPLACED FLOOR BEAM AND FASTENERS LOCATED ON FR 64 TO FR 66 + Y1292 AT AFT GALLEY AREA AS PER SRM A319 51-72-11 AND DRAWING D53472780SDR DALA2019021501005Web · corrodedCORROSION WEB LOC FR69 TO FR70 AT LEVEL STRINGER 23 LH AT AFT GALLEY, REPLACED NEW WEB LOC FR 69 TO FR 70 AT LEVEL STRINGER 23LH AT AFT GALLEY AREA AS PER A319 SRM 51-72-11 DWG #D53474180SDR DALA2019021501004Floor Support · corrodedCORROSION FLOOR BEAM -Y254 LOC FR12 TO FR24 AT FWD GALLEY AREA, REPLACED NEW FLOOR BEAM -Y254 AND FASTENERS LOC FR 12 TO FR 24 AT FWD GALLEY AREA AS PER A319 SRM 51-72-11 AND DWG #D53111462 AND DWG D53110984SDR DALA2019021501003Floor Support · corrodedCORROSION FLOOR BEAM +Y254 LOC FR12 TO FR24 AT FWD GALLEY AREA, REPLACED FLOOR BEAM +Y254 LOC FR 12 TO FR 24 AT FWD GALLEY AREA PER A319 SRM 51-72-11 AND DRAWING #D53112816 AND DRAWING D53110920SDR DALA201902154999Floor Support · corrodedCORROSION FLOOR BEAM LOC FR68 TO FR69 ON RH SIDE AT AFT GALLEY AREA, REPLACED FLOOR BEAM LOCATED FR 68 TO FR 69 ON RH SIDE AT AFT GALLEY AREA AS PER A319 SRM 51-72-11 AND DRAWING #D5347278 AND DRAWING D53472189
Back to N333NB