What was found
CORROSION FLOOR BEAM LOC FR64 TO FR66 + Y1292 AT AFT GALLEY, REPLACED FLOOR BEAM AND FASTENERS LOCATED ON FR 64 TO FR 66 + Y1292 AT AFT GALLEY AREA AS PER SRM A319 51-72-11 AND DRAWING D53472780
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FLOOR BEAM LOC FR64 TO FR66 + Y1292 AT AFT GALLEY, REPLACED FLOOR BEAM AND FASTENERS LOCATED ON FR 64 TO FR 66 + Y1292 AT AFT GALLEY AREA AS PER SRM A319 51-72-11 AND DRAWING D53472780