N334NB
Service difficulty reports · 149
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N334NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N334NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2015012000394Wire · damagedSEAT 1 AB EMERGENCY LIGHTS INOPERATIVE, REPAIRED WIRES.SDR DALA2014110405899Power Supply · inoperativeLEFT EMERGENCY POWER SUPPLY INOPERATIVE AND WILL NOT TEST. R & R EPSU IAW MM 33-51-38. OPS CHECK NORMAL.SDR DALA13025853134Battery Pack · dischargedWHEN ACFT LOST EXTERNAL POWER ON GROUND, FOUND ROWS 7-11, 15, 16, AND 18-20 & OVERWING ENTER SIGNS INOPERATIVE ON BATTERY PACK POWER. RECHARGED EMERGENCY LIGHTS, CHECKS OK REF AMM 33-51-00-710.SDR DALA13013543134Hinge Fitting · gougedVERTICAL STAB T/E RUDDER, NR 6 HINGE FITTING LOWER LUG UPPER SURFACE IS GOUGED. NR 6 HINGE FITTING IAW AMM 55-36-41-400-001-A. 450639 BFM.SDR DALA13012773134Floor Panel · damagedAFT CARGO SLOPE PANEL 162BF PUNCTURED. FABRICATED NEW PANEL ON DWG 3D25-40532.SDR DALA13012643134Floorboard · damagedAFT CARGO BAY FLOORBOARD 161NF DAMAGED. FABRICATED FLOORBOARD IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012633134Floorboard · delaminatedAFT CARGO BAY FLOORBOARD 151PE DELAMINATED. FABRICATED FLOORBOARD IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012623134Floorboard · damagedAFT CARGO BAY FLOORBOARD 151CE DAMAGED. FABRICATED FLOORBOARD IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012613134Floorboard · delaminatedAFT CARGO BAY FLOORBOARD 151VG DELAMINATED. FABRICATED FLOORBOARD IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012603134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151UG DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012593134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 152WG DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012583134Floor Panel · puncturedAFT CARGO BAY SLOPE PANEL 162FF, HAS PUNCTURE DAMAGE. FABRICATED SLOPE PANEL IAW SRM 53-02-00 FIG 209.SDR DALA13012573134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151AE DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012563134Sill · corrodedLT AFT DOOR SILL, AFT I/VB AREA AT FR68 HAS CORROSION. REMOVED CORROSION IAW 51-74-00, FOUND OUT OF LIMITS IAW SRM 53-41-14, FIG 101. REPAIRED IAW ER/A 510370-14 REV "O" SECTION I AND 53-41-14, FIG 201.SDR DALA13012553134Floorboard · damagedAFT CARGO BAY FLOORBOARD 161PF DAMAGED. FABRICATED FLOORBOARD IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012543134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 152XG DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012533134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151FE DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012523134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151DE DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209.SDR DALA13012513134Floorboard · delaminatedAFT CARGO BAY FLOORBOARD 151ZG DELAMINATED. FABRICATED NEW FLOORBOARD.SDR DALA13012503134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 152TG DAMAGED. FABRICATED NEW SLOPE PANEL.SDR DALA13012493134Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151TG DAMAGED. FABRICATED NEW SLOPE PANEL.SDR DALA13012653134Fitting · corrodedLEFT AFT DOOR SILL FWD GIRTBAR FITTING MATING SURFACE HAS CORROSION AROUND HOLES. REMOVED CORROSION IAW-74-00, FOUND OUT OF LIMITS IAW SRM 53-41-14, FIG 101. REPAIRED IAW ERA 512308-14, REV "O" SECTION I AND SRM 53-41-14, FIG 201.SDR DALA13012483134Skin · damagedLEFT WING FUEL PANEL, 540JB CUT-OUT HAS MISDRILLED HOLE. REPAIRED.SDR DALA13012283134Floor Panel · damagedFWD CARGO SLOPE PANEL 131BF DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 & SRM 53-02-00, FIG 209. REPLACED FLOOR PANEL AND INSTALLED.SDR DALA13012273134Floor Panel · damagedFWD CARGO SLOPE PANEL 132EG DAMAGED. FABRICATED SLOPE PANEL IAW DWG 3D25-40532 AND SRM 53-02-00, FIG 209. REPLACED FLOOR PANEL AND INSTALLED.SDR DALA13012263134Floor Panel · damagedFWD CARGO SLOPE PANEL 131CF DAMAGED. FABRICATED SLOPE PANEL 131CF IAW A319 DRWG 3D25-40532 AND SRM 53-02-00, FIG 209. REPLACED PANEL AND INSTALLED.SDR DALA13012253134Floor Panel · damagedFWD CARGO FLOOR PANEL 131CG DAMAGED. FABRICATED SLOPE PANEL 132CG UNDER IAW A319 DWG 3D25-40532 AND SRM 53-02-00, FIG 209. REPLACED PANEL AND INSTALLED.SDR DALA13012243134Floor Panel · damagedFWD CARGO SLOPE PANEL 132DG DAMAGED. FABRICATED SLOPE PANEL 132DG IAW DRWG 3D25-40532 AND SRM 53-02-00, FIG 209. REPLACED FLOOR PANEL.SDR DALA13012233134Floor Panel · delaminatedFWD CABIN FLOOR PANEL 222CF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13012223134Floor Panel · puncturedFWD CABIN FLOOR PANEL 221PF PUNCTURED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13012213134Floor Panel · delaminatedAFT CABIN FLOOR PANEL 261PF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13012203134Floor Panel · damagedCABIN FLOOR PANEL 241LF IS DAMAGE. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13012193134Floor Panel · corrodedAFT CABIN DOOR ENTRY FLOOR PANEL 262FF CORRODED. INSTALLATION ON THIS PANEL ACCOMPLISHED ON CARD 2500-6602. NO ALLOWABLE LIMIT ON SRM 51-73-11.SDR DALA13011873134Bolt · corrodedRT AILERON HINGE BOLT NR 4 HAS CORROSION. R & R BOLT.SDR DALA13011863134Bolt · corrodedRT AILERON HINGE BOLT NR 1 HAS CORROSION. R & R BOLT.SDR DALA13011853134Support · corrodedLT AFT UTILITY AREA BETWEEN FR 69 & FR 70 SHEAR PLATE SUPPORT HAS CORROSION. N/R 250/14. R & R SHEAR PLATE SUPPORT IAW SRM 51-42-11 AND DWG 53474180. NO ALLOWABLE LIMITS FOR SUPPORT FRAME IAW SRM A319 53-41-14. L=2.0" W=.75" D=.030". RETAIN FOR RECORDS. 5SDR DALA13011913134Pin · corrodedNR 1 ENG PYLON, REAR SHACKLE UPPER PIN AND SLEEVE HAS PITTING CORROSION. PIN AND SLEEVE INSTALLED ON WC 5450-6010-LT. OUT OF LIMITS DIMENSION OF OLD OUT OF LIMITS PINS WERE 1.5" X 0.25" X 0.062" OUT OF LIMITS IAW AMM 54-51-00.SDR DALA13011843134Floor Support · corrodedLT AFT CABIN FLOOR SUPPORT +Y1292 FR68 - FR69 CORRODED AT FR68. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND DWG 17053472000. BLENDED AREA IAW SRM 51-74-00 FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15.SDR DALA13011833134Floor Support · corrodedLT AFT CABIN FLOOR SUPPORT +Y1292 BET FR66 AND FR68 HAS CORROSION AT TWO PLACES. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND DWG 17053472000. BLENDED AREA IAW SRM 51-74-00 FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15.SDR DALA13011823134Floor Support · corrodedLT AFT CABIN FLOOR SUPPORT +Y1292 FR64 - FR66 HAS CORROSION AT FR66. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND DWG 17053472000. BLENDED AREA IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15.SDR DALA13011593134Sill · corrodedLT AFT DOOR SILL MID SHAPE SILL CORRODED. SHAPE SILL EXFOLIATED OUT OF LIMITS; NO ALLOWABLE DAMAGE LIMITS FOUND ON SRM DAMAGE. R & R CENTER SHAPE SILL IAW SRM 51-42-11 AND DWG D53480048.SDR DALA13011583134Support · corrodedRT AFT UTILITY AREA BETWEEN FR 69 & FR 70 SHEAR PLATE SUPPORT HAS CORROSION. R & R SHEAR PLATE SUPPORT IAW SRM 51-42-11, CORROSION SIZE L=.090 W=.060"D=.003". RETAIN TO RECORDS.SDR DALA13011573134Floor Panel · corrodedFWD CABIN DOOR ENTRY FLOOR PANEL 221FF CORRODED. REPLACED FLOOR PANEL IAW SRM 51-72-11 AND IPC 53-12-01, FIG 21.SDR DALA13011893134Sill · corrodedLT AFT DOOR SILL, AFT INBD AREA AT FR68 HAS CORROSION, REPAIRED IAW SRI 53-41-14-2-001-00.SDR DALA12009103134Floor Panel · damagedDAMAGE ON AFT CARGO FLOOR PANEL 151LF 6 INCHES FROM AFT EDGE & 10 INCHES FROM LEFT OTBD EDGE .500 X .700, .225 DEPTH. PERFORMED PERMANENT REPAIR IAW SRM 53-02-00.SDR DALA12009083134Connector · malfunctionedEMERGENCY ESCAPE PATH LIGHTING INOPERATIVE AT SEAT ROW 18ABC. REPOSITIONED WIRE HARNESS CONNECTOR. RESET POWER ON. PERFORMED EMERGENCY LIGHT TEST. TESTED OK. OK FOR SERVICE.SDR DALA1160443134Connector · looseMAINTENANCE FOUND SEAT 18A EMERGENCY ESCAPE PATH LIGHT INOPERATIVE. FOUND CONNECTOR LOOSE FROM SEAT HARNESS. RECONNECTED AND RESECURED SAME. OPERATIONAL CHECK GOOD. AIRCRAFT OK FOR SERVICE.SDR DALA1115503134Floor Panel · damagedAFT PIT FLOOR PANEL 161NF HAS SEVERAL INSERTS PULLED AND EXPOSED HONEYCOMB ON A 3" X 3" AREA. REMOVED FLOOR PANEL 161NF AT AFT CARGO AREA IAW AMM 53-42-17. FABRICATED NEW PANEL 161NF ON STAM TRAVELER T11/873175 IAW NWD 3D25-40582 INSTALLED PANEL 161NF IAW SRSDR 0400543134Fan · failedRECEIVED AVIONICS VENT BLOWER FAULT AND A PUFF OF SMOKE. DECLARED AN EMERGENCY AND LANDED UNEVENTFULLY AT LBF (NORTH PLATTE, NEBRASKA). FOUND AVIONICS BLOWER FAN SEIZED. SWAPPED WITH EXTRACT FAN AND APPLIED MEL PROVISIONS FOR EXTRACT FAN. AIRCRAFT RETURNED TO
Back to N334NB