What was found
LT AFT CABIN FLOOR SUPPORT +Y1292 FR64 - FR66 HAS CORROSION AT FR66. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND DWG 17053472000. BLENDED AREA IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT AFT CABIN FLOOR SUPPORT +Y1292 FR64 - FR66 HAS CORROSION AT FR66. R & R FLOOR SUPPORT IAW SRM 51-42-11 AND DWG 17053472000. BLENDED AREA IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15.