N335NW
Service difficulty reports · 199
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N335NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N335NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2016110408276Box Beam · damagedRT SIDE BOX BEAM FLANGE CRACKED AT AFT HOLE. IAW AMDS 5310-01450-01, REPAIR WAS ACCOMPLISHED IAW AMDS 5310-01450-02.SDR DALA2016081706093Light · brokenEMERGENCY FLOOR LIGHTS ON SIDE OF SEAT 1C BROKEN. REPLACED EMERGENCY LIGHT ASSY 1C AND 3C.SDR DALA2020121104049Structure · damagedDURING WALK AROUND FOUND LT OUTBOARD UPPER FLAP TRAILING EDGE DAMAGED. CORRECTIVE ACTION: REPAIRED PER A320 SRM 57-53-00 PARA 8. OK FOR SERVICE.SDR DALA2015042402906Power Supply · inoperativeDURING NON ROUTINE CHECK, FOUND AFT CABIN EPSU 13WL IS INOPERATIVE. REPLACED EPSU 13WL AND OPS CHECK WAS GOOD.SDR DALA2015042302883Power Supply · inoperativeDURING NON ROUTINE CHECK, FOUND EPSU 12WL IS INOPERATIVE. REPLACED EPSU 12WL AND OPS CHECK WAS NORMAL.SDR DALA2015040102532Floorbeam · corrodedDURING INSPECTION, FOUND FWD UTILITY AREA, FR 20; FLOOR SUPPORT BEAM-Y254 HAS CORROSION. REMOVED & REINSTALLED FLOOR SUPPORT AT -Y254 IAW SRM 51-42-11, BLENDED AREA AT FR 20 -Y254, W=2.0", L=2.0", D=0.010" IAW SRM 51-74-00, TOOL TR 14559, ORIGINAL MATERIAL SDR DALA2015031802231Skin · unknownDURING INSPECTION, FOUND SKIN IN THE AFT CARGO COMPARTMENT BETWEEN FR 55 & FR56. ACCOMPLISHED REPAIR IAW SRM 53-00-11, FIG 222.SDR DALA2015031602141Tee Fitting · corrodedDURING INSPECTION, FOUND LEFT FWD EMERGENCY EXIT LEFT LOWER TEE FITTING CORRODED. REPLACED THE TEE FITTING IAW SRM 51-42-11.SDR DALA2015031602140Tee Fitting · corrodedDURIONG INSPECTION, FOUND LEFT AFT EMERGENCY EXIT TEE FITTING CORRODED. REPLACED THE TEE FITTING IAW SRM 51-42-11.SDR DALA2015031602139Tee Fitting · corrodedDURING INSPECTION, FOUND RT AFT EMERGENCY EXIT LEFT SIDE LOWER TEE FITTING CORRODED. REPLACED THE TEE FITTING IAW SRM 51-42-11.SDR DALA2015031202124Web · corrodedDURING INSPECTION, FOUND FWD UTILITY AREA FR 20,FLOOR SUPPORT WEB -Y1732 HAS CORROSION. SSI 531189. BLENDED CORROSION IAW SRM 51-74-00, ORIGINAL MATERIAL 0.071", MATERIAL LOSS 0.024", REMAINING 0.047" FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 101. RESDR DALA2015031102121Floor Panel · damagedDURING INSPECTION, FOUND FWD CARGO PANEL 131AF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL 131AF ON VTMAE TRAVELER T15/1122402 DWG NW3B25-37705, INSTALLED ON W/C 2500-5018 FWD CARGO CLOSE VT MAE.SDR DALA2015031102120Floor Panel · puncturedDURING INSPECTION, FOUND FWD CARGO PANEL 131HF HAS MULTIPLE PUNCTURES. FABRICATED FLOOR PANEL 131HF ON VTMAE TRAVELER T15/1122403 DWG NW3B25-37705, INSTALLED ON WC 2500-5018 FWD CARGO CLOSE VT MAE.SDR DALA2015031102119Floor Panel · damagedDURING INSPECTION, FOUND FWD CARGO PANEL 131FF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL 131FF ON VTMAE TRAVELER T15/1122401, DWG NW3B25-37705, INSTALLED ON W/C 2500-5018 FWD CARGO CLOSE.SDR DALA2015031102114Door Sill · corrodedDURING INSPECTION, FOUND R1 DOOR SILL HAS CORROSION UNDER GIRT BAR FITTING, FWD. REPLACED DOOR SILL, PN D5311219120306, BATCH 2013603 IAW SRM 51-42-11, AND SRM 51-44-11. BLENDED AREA IAW SRM 51-74-00.SDR DALA2015031202122Intercostal · corrodedDURING INSPECTION, FOUND HIDDEN CORROSION ON LT SEALING PLATE BOTTOM SKIN ATTACHED INTERCOSTAL AT FRAME 58, LT SIDE. FABRICATED ON VT MAE TRAVELER T15/ 1126576 & IAW SRM 53-41-89. REMOVED AND INSTALLED INTERCOSTAL IAW SRM 51-42-11.SDR DALA2015030402035Frame · corrodedDURING INSPECTION, FOUND LT AFT UTILITY AREA FR 66 JUST ABOVE DOOR SILL HAS CORROSION, AROUND THE HOLE. REMOVED CORROSION IAW A320-53-41-12, FOUND TO BE OUT OF LIMITS, MATERIAL THICKNESS 0.098", MAT LOSS 0.020", REMAINING 0.078". INSTALLED DOUBLER IAW SRM 51-SDR DALA2016112209159Mount · corrodedCORROSION AROUND GIRT BAR MOUNT HOLES. REMOVED AND INSTALLED NEW DOOR SILL AND SPLICES IAW SRM.SDR DALA2015031202123Door Sill · corrodedDURING INSPECTION, FOUND L2 DOOR SILL IS CORRODED. INSTALLED NEW DOOR SILL,STOP CORNER 7 ANGLE SPLICE IAW 51-42-11, 51-21-11, 51-75-12, 51-74-00, 100 MAT LOSS, 53-41-14, FIG 101 AND DWG 53480019.SDR DALA2015022601732Panel · corrodedDURING INSPECTION, FOUND FWD CARGO ENTRY PANEL 132DF HAS CORROSION. REMOVED CORROSION IAW SRM 51-73-00, L= 4.00", W= 1.00", D= 0.043", TR83340. NO LIMITS FOUND IAW SRM NOTED.SDR DALA2015022501726Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA BETWEEN FRAME 66-69, FLOOR SUPPORT BEAM -Y1292 HAS CORROION, S5I 534147, BLENDED AREA AT FRAME 66 IAW TRM 53-41-15 AND SRM 51-74-00. AFTER REWORK: L=2.3",W=1", D=.036", OUT OF LIMIT IAW TRM 53-41-15 MAX DEPTH ALLOWED,.SDR DALA2015022501730Stringer Splice · corrodedDURING INSPECTION, FOUND FWD CARGO COMPARTMENT STRINGER SPLICE CORRODED AT FRAME 26/FRAME 27 S-44-0. NO REPAIR LIMITS ON FACTORY STRINGER SPLICE. R & R STRINGER SPLICE IAW SRM 51-42-11. NEW STRINGER SPLICE FABBED ON VTMAE TRAVELER T15/1122311 IAW SRM 53-00-SDR DALA2015022401724Door Sill · corrodedDURING INSPECTION, FOUND LT AFT UTILITY AREA FR68 JUST ABOVE DOOR, DOOR SILL HAS CORROSION, AROUND THE HOLE. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-41-12, L=0.95", W=0.75" ORIGINAL MATERIAL 0.098". REMOVED 0.046", REPAIRED FRAME IAW SRM 5SDR DALA2015021401253Floor Panel · damagedDURING INSPECTION, FOUND CABIN FLOOR PANEL 232 FF HAS A HOLE. FABRICATED A NEW FLOOR PANEL IAW DWG NW3025-37498 AND INSTALLED.SDR DALA2015021401251Floorboard · damagedDURING INSPECTION, FOUND CABIN FLOORBOARD 231CF HAS HOLE. FABRICATED A NEW FLOORBOARD IAW DWG NW3025-37498 AND INSTALLED ON CARD 2500-6601.SDR DALA2015021401250Floor Panel · damagedDURING INSPECTION, FOUND FLOOR PANEL 231 QF HAS FACE SKIN DAMAGE. FABRICATED NEW FLOOR PANEL IAW NW3025-37498.SDR DALA2015021901453Floor Support · crackedDURING INSPECTION, FOUND COCKPIT AREA BETWEEN FRAMES 11 & 12 + Y765 FLOOR SUPPORT CRACKED. REMOVED & REPLACED IAW SRM 51-42-11.SDR DALA2015021901447Seat Track · corrodedDURING INSPECTION, FOUND FWD UTILITY AREA FRAME 20, SEAT TRACK -Y 765 CORRODED. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-15. REPLACED THE SEAT TRACK BETWEEN FRAMES 12-24 IAW SRM 51-42-11 AND TRM 53-21-01.SDR DALA2015021101195Floorbeam · corrodedDURING INSPECTION, FOUND FRAME 20, FLOORBEAM -Y1292 CORRODED. BLENDED CORROSION IAW SRM 51-74-00 AND FOUND OUT OF LIMITS IAW SRM 53-11-15, FIG 102. REPLACED IAW SRM 51-42-11.SDR DALA2015021001124Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY AREA BETWEEN FRAMES 66 TO 70 FLOOR SUPPORT -Y765 HAS CORROSION. REMOVED CORROSION IAW SRM 51-22-00, FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REPLACED THE FLOOR SUPPORT IAW TRM 53-21-01.SDR DALA2015020801028Floor Support · corrodedDURING INSPECTION, FOUND FWD UTILITY AREA FLOOR SUPPORT BETWEEN FRAMES 20 - 21 -Y 189 CORRODED. BLENDED AREA IAW SRM 51-74-00. FOUND OUT OF LIMITS IAW SRM 53-11-14, FIG 107.SDR DALA12005743235Wire · looseDURING NON ROUTINE CHECK, FOUND THE EMERGENCY FLOOR PATH LIGHT AT ROW 24C INOPERATIVE. MAINTENANCE SECURED LOOSE WIRE AT ROW 24C AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12005633235Light · inoperativeDURING NON ROUTINE CHECK, FOUND EMERGENCY EXIT LIGHT HAS MANY BURNT LAMPS. MAINTENANCE REPLACED LAMPS AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12005623235Light · inoperativeDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT 23C INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12005243235Battery Pack · inoperativeDURING NON ROUTINE CHECK, EMERGENCY LIGHT AT 1C FAILED TEST. MAINTENANCE REPLACED BATTERY PACK AND FUNCTIONAL TEST WAS NORNAL.SDR DALA1130223235Floor Panel · erodedAFT CARGO COMPT FLOOR PANEL 161AF IS DELAMINATED AND ERODED AROUND CUT OUT. REMOVED PNL 151AF IAW AMM 53-42-17, PB401. PNL161AF FABRICATED ON TRAVELER T11/880745 IAW DWG 3025-3770; MAT ID: A402AB-60X144 BATCH: 1886727. INSTALLED 161AF IAW AMM 53-42-17, PB401SDR DALA1130213235Floor Skin · crackedAFT CARGO COMPT FLOOR PANEL 151GF HAS CRACKS AND MULTIPLE DENTS ON UPPER SKIN. REMOVED PNL 15GF IAW AMM 53-42-14, PB 401. FABRICATED NEW ON STAM TRAVELER T11/880729 IAW DWG 3025-3770, MAT ID A402AB-60X144, BATCH 1886727. INSTALLED 151GF IAW AMM 53-42-14PB40SDR DALA1108963235Seat Track · corrodedCORROSION AT SEAT TRACK FLANGE, RBL "60" INBD OF FRAME 20 RT CORROSION REMOVED & CONTAINED, CUTOUT DAMAGE, FABRICATED,REPAIR ANGLE FROM .080 7075-0 HEAT TREATED. DRILLED, TRIMMED & DEBURRED. TREATED & PRIMED & INSTALLED IAW 53-11-15. REQUIRED INSP COMPLETE.SDR DALA1103513235Connector · brokenDURING EMERGENCY LIGHT TEST FOUND ROW 5C PATH LIGHT INOPERATIVE, REPLACED BROKEN CONNECTOR AND TESTS OK.SDR DALA1026273235Wire · damagedDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT ROW 22L AND 25L INOPERATIVE. MX REPLACED BLACK WIRE AT JIFFY AND PERFORMED SUCCESSFUL TEST. ACFT RETURNED TO SERVICE.SDR NWAA093673235Epsu · dischargedEPSU TEST FAULTED THE OVERWING ESCAPE SLIDE LIGHT SW/EPSU. REPLACED EPSU AND TESTED GOOD.SDR NWAA074243235Skin · gougedDURING GROUND OPERATIONS FUSELAGE SKIN WAS GOUGED ON FORWARD SIDE OF CARGO DOOR OPENING AT STA C24-C24A BETWEEN STRINGERS 36R-37R. REPAIRED PER EA 32-211163.SDR NWAA074233235Skin · gougedDURING GROUND OPERATIONS FUSELAGE SKIN WAS DENTED AND GOUGED BETWEEN STRINGER 34 TO 38 FRAMES 19 TO 24. REPAIRED PER EA 32-211270.SDR 0402163235Fan · failedDURING CRUISE, PILOTS EXPERIENCED SLIGHT SMOKE AND BURNING ODOR. DIVERTED TO DES MOINES AND LANDED UNEVENTFULLY. INSPECTED CABIN, AVIONICS BAY, AND CARGO BAYS AND FOUND NO DEFECTS. FOUND LEFT CABIN FAN SUPPLY CIRCUIT BREAKER POPPED AND LEFT FAN INDICATION ISDR 9802473235Wire · brokenDURING TEST OF EMERGENCY LIGHTS, FOUND ESCAPE PATH LIGHTS INOPERATIVE ON LAST THREE SEAT ROWS. MAINTENANCE REPAIRED BROKEN WIRE AT SIDEWALL CONNECTOR. OPERATIONAL CHECK OK.SDR 9700093235Sensor · out of adjustDURING ROTATION, RECEIVED FORWARD CARGO DOOR OPEN AND MASTER CAUTION WARNING. AIRCRAFT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. DOOR INDICATION RETURNED TO NORMAL AFTER CLEARING RUNWAY. MAINTENANCE PERFORMED ADJUSTMENT OF THE FORWARD CARGO DOOR PROXIMITSDR 9623603235Power Supply · inoperativeDURING LINE MAINTENANCE CHECK, FOUND BOTH AFT DOOR EMERGENCY EXIT SIGNS INOPERATIVE. REPLACED LEFT AFT EPSU. OPERATIONAL CHECK OK.SDR 9622303235Fan · seizedDURING APPROACH AT 7,000 FEET, CREW NOTED A BURNING SMELL IN COCKPIT FOLLOWED FIVE MINUTES LATER BY A VENT EXTRACT FAULT. FOLLOWED COCKPIT OPERATING MANUAL PROCEDURES, DECLARED AN EMERGENCY AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE AVIONICS COOLING SDR 9605363235Bscu · malfunctionedDURING TAXI IN AT THE GATE, THE BRAKES DID NOT RESPOND. USED ENGINE THRUST REVERSE TO STOP AIRCRAFT SAFELY AT THE GATE. THE BRAKES GRABBED AS THE AIRCRAFT CAME TO A STOP. MAINTENANCE REPLACED THE BRAKE STEERING CONTROL UNIT. OPERATIONAL CHECK OK.
Back to N335NW