What was found
DURING INSPECTION, FOUND FWD UTILITY AREA FR 20,FLOOR SUPPORT WEB -Y1732 HAS CORROSION. SSI 531189. BLENDED CORROSION IAW SRM 51-74-00, ORIGINAL MATERIAL 0.071", MATERIAL LOSS 0.024", REMAINING 0.047" FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 101. REPLACED FLOOR SUPPORT BATCH 2144824, PART D5311278400301,