N352NW
Service difficulty reports · 179
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N352NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N352NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2015033002519Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CORNER FITTING FRAME 68 RT AT AFT GALLEY AREA, MEASURES APPROXIMATELY L:1", W:0.437", D:0.002". REPLACED CORNER FITTING AT FRAME 68 RT AFT GALLEY AREAS IAW SRM 51-72-11 AND DWG D534-80019.SDR DALA2015033002501Stringer · corrodedDURING INSPECTION, FOUND CORROSION ON STRINGER COUPLING AT STR 42L BETWEEN FR 30 AND 31 IN FWD CARGO COMPARTMENT. MEASURES APPROXIMATELY L:0.5", W:0.339, D:0.002". REPLACED COUPLING AT STR 42L BETWEEN FR 30 AND FR 31 IN FWD CARGO COMPARTMENT IAW SRM 51-72-11 SDR DALA2015032902499Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON LOWER SILL CENTER FITTING RT AT AFT GALLEY AREA . MEASURES APPROXIMATELY L=0.376", W=0.231", D=0.002", SSI 534147. REPLACED CENTER FITTING RT AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480019.SDR DALA2015032802498Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y254 AT FWD GALLEY AREA FROM FRAME 16 TO FRAME 21, L=0.700", W=0.300", D=0.003". REPLACED FLOORBEAM +Y254 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 24 IAW SRM 51-72-11 AND DWG D53112816.SDR DALA2015032802497Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y1292 AT FWD GALLEY AREA FROM FRAME 16 TO FRAME 20, L=2", W=1", D=0.005". REPLACED FLOORBEAM -Y1292 AT FWD GALLEY AREA FROM FR 12 TO FR 24 IAW SRM 51-72-11 AND DWGS D53112812, D53110920, D53110984.SDR DALA2015032802496Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y1292 AT FWD GALLEY AREA FROM FRAME 16 TO FRAME 20, L=0.500", W=0.300", D=0.002. REPLACED FLOORBEAM +Y1292 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 24 IAW SRM 51-72-11 AND DWGS D53112812, D53110920.SDR DALA2015032802494Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM-Y765 AT AFT GALLEY AREA ON FRAME 68, L=1", W=0.50", D=0.003". REPLACED FLOORBEAM -Y765 AT AFT GALLEY AREA FROM FRAME 66 TO FRAME 70 IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2015032802493Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM -Y765 AT AFT GALLEY AREA ON FRAME 66 L =3", W=1", D=0.003". EVALUATED FLOORBEAM -Y765 AT AFT GALLEY AREA FROM FR 64 TO FRAME 66 IAW SRM 51-72-11 AND DWG D5347832, D53472816.SDR DALA2015032802492Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOOR STRUCTURE BEAM -Y465 AT AFT GALLEY AREA FROM FRAME 66 TO FRAME 67, L=8", W=3", D=0.006". REPLACED FLOORBEAM -Y465 LOCATED AFT GALLEY AREA FROM FRAME 64 TO FRAME 67+5" IAW SRM 51-72-11 AND DWG D53472816.SDR DALA2015032802485Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOOR STRUCTURE LONGITUDINAL BEAM RT SIDE AT AFT GALLEY AREA FROM FRAME 65 TO FRAME 66, L=3", W=1", D=0.004". SSI 534147. REPLACED FLOORBEAM LOCATED BTE FRAME 65 TO FRAME 66 AND -Y1450 TO -Y1589 AND FASTENERS IAW SRM 51-SDR DALA2015032702439Dummy Rail · corrodedDURING INSPECTION, FOUND CORROSION ON RAIL DUMMY -Y81 AT FWD GALLEY AREA FROM FRAME 12 TO FRAM E 16, L=2", W=1", D=0.003", 531189. REPLACED RAIL DUMMY -Y81 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 16 IAW SRM 51-72-11 AND DWG D53112828.SDR DALA2015032702438Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y765 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 16, L=3", W=2", D=0.002", SSI 531189. REPLACED FLOORBEAM +Y765 LOCATED ON FWD GALLEY AREA FROM FR 12 TO FR 24 IAW SRM 51-72-11 AND DWG D53110984 AND D53110920.SDR DALA2015032702437Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y765 AT AFT GALLEY AREA ON FRAME 68 L=2", W=1", D=0.002", SSI 534147. REPLACED FLOORBEAM Y765 AT AFT GALLEY AREA FROM FRAME 66 TO FRAME 70 IAW SRM 51-72-11 AND DWG D53472816, D53472800.SDR DALA2015032702436Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOOR STRUCTURE BEAM Y765 AT AFT GALLEY AREA FROM FRAME 64 TO FRAME 66, L=2", W=1", D=0.002". SSI 534147. REPLACED FLOOR STRUCTURE BEAM Y765 AT AFT GALLEY AREA FROM FRAME 64 TO FRAME 66 IAW SRM 51-72-11 AND DWG D5347283SDR DALA2015032702435Floorbeam · corrodedDURING INSPECTION, FOUND ELONGATED HOLE FLOOR STRUCTURE CROSS SECTION + Y1162 AT AFT GALLEY AREA ON FRAME 68, SSI 534147. REPLACED CROSS SECTION FLOOR STRUCTURE Y1162 AT AFT GALLEY AREA ON FRAME 68 IAW SRM 51-72-11 DWG D53474250.SDR DALA2015032702434Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOOR STRUCTURE LONGITUDINAL LT SIDE AT AFT GALLEY AREA FROM FRAME 65 TO FRAME 66, L=1", W=0.50", D=0.003". SSI 534147. REPLACED FLOOR STRUCTURE LONGITUDINAL LT SIDE AT AFT GALLEY AREA FROM FRAME 65 TO FRAME 66 IAW SRM 51SDR DALA2015032702431Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON CENTER FITTING LOCATED AT FWD GALLEY AREA FROM FRAME 16 TO FRAME 19 AND STRINGER 23. LT SIDE SSI 531180, REPLACED CENTER FITTING AND FASTENERS LOCATED AT FWD GALLEY AREA FROM FRAME 16 TO FRAME 19 AND STR 23L IAW SRM 51-72SDR DALA2015032602423Shear Tie · corrodedDURING INSPECTION, FOUND CORROSION ON CLEAT AT FRAME 34 BETWEEN STR 43R AND STR 44 IN FWD CARGO COMPARTMENT, MEASURES APPROXIMATELY L:0.559", W:0.219", D:0.002", SSI 532180. REPLACED CLEAT AT FRAME 34 BETWEEN 43R AND STR 44 IN FWD CARGO COMPARTMENT IAW SRM SDR DALA2015032602422Dummy Rail · corrodedDURING INSPECTION, FOUND CORROSION ON RAIL DUMMY -Y189 AT FWD GALLEY AREA FROM FRAME 20 TO FRAME 21, L=2", W=1", D=0.004", SSI 531189. REPLACED RAIL DUMMY -Y189 AT FWD GALLEY AREA FROM FRAME 20 TO FRAME 24 IAW SRM 51-72-11 AND DWG D53112834.SDR DALA2015032602421Shear Tie · corrodedDURING INSPECTION, FOUND CORROSION ON CLEAT AT FRAME 31 BETWEEN STR 42R AND STR 43R IN FWD CARGO COMPARTMENT. MEASURES APPROXIMATELY L:0.762", W:0.596", D:0.002", SSI 532180. REPLACED CLEAT AT FR 31 BETWEEN STR 42R AND STR 43R IN FWD CARGO COMPARTMENT IAW SRSDR DALA2015032602407Shear Tie · corrodedDURING INSPECTION, FOUND CORROSION ON CLEAT AT FRAME 34 BETWEEN STR 42R AND STR 43R IN FWD CARGO COMPARTMENT. MEASURES APPROXIMATELY L:0.718", W:0.250", D:0.002", SSI532180. FWD CARGO COMPARTMENT IAW SRM 51-72-11 AND DWG D53231712.SDR DALA2015032502409Floor Support · corrodedDURING INSPECTION, FOUND CORROSION ON FLOORBEAM +Y512 AT AFT GALLEY AREA FROM FRAME 64 TO FRAME 66, L=12", W=3", D=0.004", SSI 534147. REPLACED FLOORBEAM +Y512 AT AFT GALLEY AREA FROM FRAME 64 TO FRAME 66 IAW SRM 51-72-11 AND DWG D53472815.SDR DALA2015032202293Dummy Rail · corrodedDURING INSPECTION, FOUND CORROSION ON RAIL DUMMY Y503.2 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 16, L=2", W=1", D=0.004". REPLACED RAIL DUMMY Y503.2 AT FWD GALLEY AREA FROM FR12 TO FR16 IAW SRM 51-72-11 AND DWG D53112825 AND D53110984.SDR DALA12000673252Light · inoperativeDURING NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT SEAT 15 INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY AND OPS CHECKED NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1163933252Connector · not seatedDURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHT AT SEAT 10C INOPERATIVE. MAINTENANCE RE-SEATED LOOSE CONNECTOR UNDER SEAT 10C AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1130373252Skin · corrodedFUSELAGE FROM FR 69 TO 70 AROUND VACUUM OUTLET HAS CORROSION. BLENDED AREA IAW SRM 51-73-00. DIM; L=1.0" W=0.3" D=0.009" OUT OF LIMITS IAW SRM 53-41-11. CUT OUT IAW SRM 53-41-11 FIG 205. FABBED REPAIR PARTS IAW SRM 53-41-11. PERFORMED HFEC IAW NTM 51-00-08SDR DALA1035013252Bottle · emptyDURING LINE CHECK FOUND DOOR 1R, DOOR ASSIST BOTTLE IS DEPRESSURIZED FRANGIBLE DISK IS RUPTURED. R & R 1R DOOR DAMPER EMERGENCY OPERATING CYLINDER IAW AMM 52-11-14.SDR DALA1012273252Power Supply · inoperativeDURING A NON ROUTINE CHECK, THE EMERGENCY POWER SUPPLY UNIT FAILED TEST. REPLACED EPSU AND CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR 0004363252Packing · leakingDURING CRUISE RECEIVED "HYD Y RSVR LO LVL" MESSAGE. SHUT DOWN THE YELLOW HYDRAULIC SYSTEM PER COM PROCEDURES AND CONTINUED TO FINAL DESTINATION WITHOUT INCIDENT. MAINTENANCE REPLACED LEAKING O-RING ON LINE BETWEEN PTU MANIFOLD AND PTU. RESERVICED SYSTEM. NO