What was found
DURING INSPECTION, FOUND CORROSION ON LOWER SILL CENTER FITTING RT AT AFT GALLEY AREA . MEASURES APPROXIMATELY L=0.376", W=0.231", D=0.002", SSI 534147. REPLACED CENTER FITTING RT AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480019.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON LOWER SILL CENTER FITTING RT AT AFT GALLEY AREA . MEASURES APPROXIMATELY L=0.376", W=0.231", D=0.002", SSI 534147. REPLACED CENTER FITTING RT AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480019.