N35953
Service difficulty reports · 18
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N35953' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N35953' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026032014706Lens · broken12F LIGHT PROXIMITY LENS BROKEN. REMOVED AND REPLACED LIGHT PROXIMITY REF. CMM 25-26-36. GOOD FOR SVC. ITEM OK.PARTS USED: 78-3300-3-0098,QTY :1SDR CALA2026021713842Control Card · faultedANTI-SKID ADVISORY FAULT DETECTED IN ANTISKID SYS. AHM INDICATES MM 32-30042 FAULTING THE RDC 7 RT INBD BRAKE SYS CONTROL CARD HAS NO INPUT FROM MAIN GEAR AXLE RDC 7 ON CAN BUS. RDC M/E 78-3242-9-9011. CREW STATED HAPPENED WHILE TAKING OFF. THEY SAW THE STSDR CALA2026010812801Battery Pack · inoperativeOFAR FLASHLIGHT FAILED OPS TEST (RED LED OBSERVED). FLASHLIGHT TURNS OFF AUTOMATICALLY WITHIN 03 SECONDS FLASHLIGHT BATTERY PACK INOP. FLASHLIGHT BATTERY PACK REPLACED AT THE OFAR. INSTALLATION CHK AND OPS TEST CARRIED OUT, FOUND SATISFACTORY. IAW AMM B787-A-SDR CALA2026010812800Light · inoperativeFOUND SEAT 4D EMERGENCY LIGHT INOP REPLACED DUE TO INOPERATIVE. EMERGENCY LIGHT ASSY SEAT 4D EMERGENCY LIGHT REPLACED IAW B787-A-33-51-06-00A-520A/720A-A. OPS TEST SATIS.SDR CALA2025061805674Skin · puncturedPUNCTURE TO FUSELAGE AFT OF BULK CARGO DOOR BEING CARGO LOADING LIGHT WITH FIBRE BREAKTHROUGH REF PIC AND LOCATIONDAMAGE NOTED AT APPROX STATION 1760 WATERLINE 31L AFTER FURTHER EVALUATION DAMAGE IS A PUNCTURE WITH A SCRATCH. PUNCTURE GOES THROUGH CARBON FIBERSDR CALA2025060505279Battery Pack · faultedDURING INSPECTION OF EMERGENCY FLASHLIGHT IT WAS FOUND #06EA BATTERY PACK NEAR OF LIFE LIMIT AT POSITIONS FA SEAT FWD DOOR L1, FA SEAT AFT DOOR L1, FA SEAT FWD DOOR L2, FA SEAT AFT DOOR L2, FA SEAT FWD DOOR R2 AND FA SEAT AFT DOOR R2. REMOVED AND REPLACED #06ESDR CALA2025012101952Battery · inoperativeWIRELESS EMERGENCY LIGHTING SYSTEM CONTROL UNIT BATTERY - REMOVAL PREPARE FOR THE REMOVAL - POSITION L11X PER JOB CARD INSTRUCTIONS REPLACED WELLS BATTERY POSITION L11XIAW JOB CARD M&E# 79-3351-1-0008 INSTRUCTIONS AND AMM33-51-00. OPS CHECK NORMAL, NO FAULTS NSDR CALA2023051701552Panel · missingLH WING NO.5 SLAT OUTBD TRACK FAIRING PANEL MISSING NO OTHER DAMAGE NOTED. PLACED CDL57L.NEED TOMC APPROVAL CDL 57L UNABLE TO CDL DUE TO #5 SLAT REQUIRED FLEX DOOR REQUIRED. REPLACED PANEL REFAMM B787-A-57-41-10, CHKD OK.SDR CALA2022072701887Sensor · looseSLATS DRIVE CAUTION PRIMARY AND SECONDARY SLAT DRIVES HAVE FAILED TO OPERATE, OR HAV E BEEN SHUT DOWN BECAUSE OF AN ASYMMETRY, SKEW/LOSS, DISAGREE, O R UNCOMMANDED MOTION. 0 SLAT DRIVE FAIL AT 6000 MESSAGE 27-22321. #5 SLAT SKEW SENSOR FAULT. SEE ATTACHED ENTRSDR CALA2022072501878None · failedSATCOM SYSTEM FAULTS. REPLACE THE SDU.SATCOM GROUND TEST FAILS.SATCOM DOES NOT STAY LOGGED ON AND IS NOT AVAILABLE.SDU ORDERED FOR REPLACEMENT. REPLACED SATCOM RECEIVER TRANSMITTER, SATCOM OPS NORMAL, LINK TEST OK, NO CMC OR STATUS MESSAGES.SDR CALA2022062001542Slat System · faultySLATS DRIVE EIDAS DISPLAYED ON CLIMB OUT PILOTS GOT A "SLAT DRIVE" MESSAGE. WHILE RUNNING CONFIGURATION.. UPON ENTERING ORD, THEY WERE LIMITED TO SEE ATTACHED IMAGES. THROUGH THE QRH FOR THAT, THEY GOT A FLAP/SLAT CONTROL TO WHICH DROPPING FLAPS AND SLATS TOSDR CALA2020120701345Skin · damagedLT WING NR 6 SPOILER LOWER SURFACE FOUND HIT BY ONE BOLT, REFER NON-ROUTINE NR 9420932. LT WING NR 6 SPOILER LOWER SURFACE PERFORM PERMANENT REPAIR, AS PER SRM B787-A-57-70-01-01A-661A-A AND SRM B787-A-51-73-02-01A-663A-A AND SRM B787-A-51-73-05-01A-663A-A RESDR CALA2020120701344Terminal · detachedDURING PERFORM EMERGENCY LIGHT OPERATIONS TEST FOUND PAX SEAT 3D EMERGENCY LIGHT CONNECTOR WIRES DETACHED. REPLACED PAX SEAT 3D EMERGENCY LIGHT CONNECTOR AND PERFORMED OPERATIONAL TEST OF THE EMERGENCY LIGHT FOUND ''SATISFACTORY'', REF TO SWPM 20-30-15 REV 75SDR CALA2019101801765A/C Pack · failedPACK R, ADVISORY, PACK IS FAILED OR MANUALLY SHUT DOWN. IAW-FIM, 21-50-F1-73A-421A: MAINTENANCE MESSAGE 21-65113, 21-65114. USED THE CMCF TO PERFORM THIS GROUND TEST: 21 CABIN AIR CONDITIONING/TEMP CONTROL SYSTEM, SYSTEM TEST, RIGHT PACK SYSTEM AIR ON. SYSTEM SDR CALA2017022400468Battery Pack · dischargedDOOR 4L EMERGENCY FLASHLIGHT DOES NOT TEST. REPLACED BATTERY PACK FOR EMERG FLASHLIGHT AT SEAT 4L. CHECKS GOOD.SDR CALA2016060600352Oven · odorELECTRICAL & HEAT ODOR EMANATING FROM GALLEY B AREA. FIM DMC B787-A-05-51-99-99A-282A-A FOLLOWED. SMOKE & ODOR QUESTIONNAIRE COMPLETED & FWD TO TOMC. OVEN 408 FOUND CRITICAL ERROR FUSE BROKEN. OVEN INSPECTION CUT OUT OVEN OVER HEAT. OVEN REPLACED IAW DMC SDR CALA2016042800261Monitor · failedSTRONG METALLIC BURNT ODOR OBSERVED IMMEDIATELY AFTER TAKEOFF AT AFT GALLEY & ACFT 4LR JUMP SEAT AREA, QUICKLY DISAPPEARED AFTER TAKEOFF. NO SMOKE OBSERVED REF LOG PG 8488129. INSPECTED AFT GALLEYS, ALL EQUIP FOR EVIDENCE OF SMOKE & ODOR, FOUND NONE. AIR COSDR CALA2015121801007Water Heater · leakingWATER LEAKING FROM FWD LAVATORY, FLOODED FWD GALLEY IAW NR 4945615 FOR REPAIR OF LEAK. ACCOMPLISHED CLEANUP OF POTABLE WATER SPILL IAW ECRA 2011-0100, LAVATORY & GALLEY SPILL STEP 2 A & 2 B, IN-DEPTH CLEAN UP. PLACED ON DIP TO PERFORM HEAVY SUPPLEMENTAL INSP