N360NW
Service difficulty reports · 157
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N360NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N360NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2016091206546Control Valve · faultyON DESCENT, ECAM WARNING: CABIN PRESSURE EXCESS, CABIN ALT AND CABIN PRESSURE LOW DIFF PRESSURE. CABIN ALTITUDE CLIMBED TO OVER 8800 FT. EMERGENCY WAS DECLARED AND THE FLIGHT LANDED UNEVENTFULLY. REPLACED THE RT PACK FCV, FLOW CONTROL VALVE. THE LT PACK WASDR DALA2016081205959Light · misinstalledDOOR 1 LT & RT EMERGENCY EXIT LIGHTS INOPERATIVE, INTERIOR. OBSERVE POLARITY WHEN RECONNECTING LIGHTS OPS CHECK GOOD.SDR DALA2016070505104Connector · looseDOOR 2L OVERHEAD EMERGENCY LIGHT INOPERATIVE, CONNECTOR 7245VC LOOSE RE-CONNECTED.SDR DALA2016012800726Shear Tie · corrodedCORROSION ON SHEAR TIE AT FRAME 26 T AND STR 43 TO 44R IN FWD CARGO COMPARTMENT. REPLACED THE SHEAR TIE IAW SRM 51-72-11 AND DWG D53231712.SDR DALA2016112509234Profile · not reportedPROFILE IN AFT CARGO COMPARTMENT ON FRAME 56 BETWEEN STRINGER 38L TO STRINGER 41R. REMOVED AND REPLACED THE PROFILE IAW SRM.SDR DALA2016012600725Shear Tie · corrodedCORROSION ON SHEAR TIE IN AFT CARGO COMPARTMENT ON FRAME 61 BETWEEN STR 43 TO 44R. REPLACED THE SHEAR TIE IAW 51-72-11, DWG D53470914 AND DWG D53470332.SDR DALA2016012500724Structure · corrodedCORROSION ON LOWER SILL AT AFT GALLEY AREA ON STR 23R BETWEEN FRAME 66 TO FRAME 68. REPLACED LOWER SILL AT AFT GALLEY AREA ON STR 23R BETWEEN FRAME 66 TO FRAME 68 IAW SRM 51-72-11 AND DWGS D53480019, D53480150, D53480076, MEASURES OF CORROSION L=2.590", W=1SDR DALA2016012100730Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y1162 AT AFT GALLEY AREA BETWEEN FRAMES 67+15 TO 69+5. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472088, DWG D53472800.SDR DALA2016012100729Floor Support · corrodedCORROSION ON FLOOR STRUCTURE COUPLING AT LEVEL -Y 160 FR 68 OUTBOARD UPPER POSITION AT AFT GALLEY AREA . REPLACED COUPLING AT LEVEL -Y160, FRAME 68 IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2016012100728Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y512 AT AFT GALLEY AREA BETWEEN FRAMES 64 TO 67+15. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DWG D53472815.SDR DALA2016012100509Floor Support · corrodedCORROSION ON FLOORBEAM Y465 AT AFT GALLEY FRAME 64 TO FRAME 67 PLUS 15 IN. REPLACED FLOORBEAM Y465 IAW SRM 51-72-11.SDR DALA2016012000508Floor Support · corrodedCORROSION ON FLOORBEAM Y160 AT AFT GALLEY BETWEEN FRAME 66 TO 68. REPLACED FLOORBEAM IAW SRM 51-72-11.SDR DALA2016011900505Dummy Rail · corrodedCORROSION ON RAIL DUMMY Y503.2 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 16. REPLACED RAIL DUMMY Y503.2 IAW SRM 51-72-11.SDR DALA2016111808970Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1292 BETWEEN FRAMES 12 TO 24. REPLACED THE FLOOR SUPPORT.SDR DALA2016011800386Floor Support · corrodedCORROSION ON FLOOR SUPPORT BETWEEN FRAMES 66+5 TO 67+15" +Y1225. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472815.SDR DALA2016011800385Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1162 AT AFT GALLEY AREA BETWEEN FRAMES 67+15 TO 69+5. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2016011800384Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y254 AT FWD GALLEY AREA BETWEEN FRAMES 12 TO 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53110984 AND DWG D53110900.SDR DALA2016011800383Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y765 AT AFT GALLEY AREA BETWEEN FRAMES 66+5" TO 70. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472092.SDR DALA2016011700382Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y254 AT FWD GALLEY AREA BETWEEN FRAMES 12 TO 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53110900.SDR DALA2016011600381Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y189 AT FWD GALLEY AREA BETWEEN FRAME 20 TO 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53111406.SDR DALA2016011500377Seat Track · corrodedCORROSION ON SEAT TRACK -1292 AT FWD GALLEY AREA BETWEEN FRAMES 12 TO 24. REPLACED THE SEAT TRACK IAW 51-72-11 AND DWG 53110900.SDR DALA2016011500376Floor Support · corrodedCORROSION ON FLOOR SUPPORT +765 AT FWD GALLEY BETWEEN FRAMES 12 TO 24. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53112812.SDR DALA13043703260Connector · damagedDURING NON-ROUTINE CHECK, FOUND EMERGENCY LIGHTS AT SEATS 23 ABC AND 25 ABC INOPERATIVE. MX REPLACED CONNECTOR PINS IN CONNECTOR AND FUNCTIONAL CHECKED NORMAL.SDR DALA13035993260Connector · unsecureDURING NON ROUTINE CHECK, FOUND SEAT 16C EMERGENCY LIGHT INOPERATIVE. MX SECURED WIRING HARNESS CONNECTIONS AT 16C AND FUNCTIONAL CHECKED NORMAL.SDR DALA1164363260Light · inoperativeDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT ROW 24 INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1159573260Connector · defectiveDURING A NON ROUTINE CHECK, FOUND FWD EMERGENCY PATH LIGHT ON SEAT 4B INOPERATIVE. MAINTENANCE REPLACED NEW CONNECTOR ON WIRING AND OPERATIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1016163260Battery · failedDURING A NON ROUTINE CHECK, FOUND THE RIGHT EMERGENCY LIGHTS FAULTING TEST. REPLACED THE BATTERY AND PERFORMED SUCCESSFUL TEST. A/C RETURNED TO SERVICE.SDR DALA109663260Door Frame · corrodedDURING M-CHECK FOUND CORROSION ON RT AFT EMERGENCY EXIT DOOR INTERIOR LOWER FRAME. REPAIRED IAW SRM 51-42-11, SRM 51-44-11.SDR DALA109553260Mount · gougedDURING M”-CHECK, FOUND NR 1 PYLON AFT ENGINE MOUNT INBD SIDE HAD SEVERAL GOUGES. REPAIRED IAW SRM ERA 481877-14 ASSOCIATED ERA 13-481877.SDR DALA109543260Skin · damagedDURING M-CHECK AND WHILE ACCOMPLISHING PHONE ANTENNA REPAIR (2) PILOT HOLES WERE MISDRILLED. REPAIRED IAW SRM 53-00-11 FIGURE 209, SRM 51-44-11, SRM 51-21-11, ERA 481865-14.SDR DALA109483260Floor Support · corrodedDURING M-CHECK FOUND CORROSION ON RT AFT CABIN FLOOR SUPPORT BEAM AT Y765, FR64-FR66. REPAIRED IAW SRM 51-44-11, SRM 51-42-11.SDR DALA109513260Sill · corrodedDURING M-CHECK FOUND CORROSION ON AFT CARGO COMPARTMENT DOOR SILL WEB AT FR53 S39R-S41R. REPAIRED IAW SRM 51-42-11, SRM 51-44-11, 51-72-11.SDR DALA109473260Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL NR 241HF BOTTOM SURFACE. FABRICATED REPLACEMENT FLOOR PANEL IAW DWG 3D25-37705.SDR DALA109363260Floor Panel · corrodedR & R FLOOR PANEL NR 261FF IN THE AFT CABIN IAW SRM 53-42-12, FIG 860, DUE TO CORROSION BEING BEYOND LIMITS.SDR DALA108803260Floor Panel · dentedDURING M-CHECK FOUND FLOOR PANEL HAD DENTS ON EXTERNAL SURFACE. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA108853260Floor Panel · damagedDURING M-CHECK FOUND DENTS AND EDGE DAMAGE ON FLOOR PANEL 151PF. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA108843260Floor Panel · dentedDURING M-CHECK FOUND FLOOR PANEL 131AF HAD DENTS ON EXTERNAL SURFACE. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA108833260Floor Panel · damagedDURING M-CHECK FOUND PUNCTURES AND DENTS ON FLOOR PANEL 151LF. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA108823260Floor Panel · damagedDURING M-CHECK FOUND MULTIPLE DENTS AND EXPOSED HONEYCOMB ON FLOOR PANEL 161DF. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA108813260Floor Panel · damagedDURING M-CHECK FOUND PUNCTURES AND DENTS ON FLOOR PANEL 161AF. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA108793260Floor Panel · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR PANEL 261FF. REPLACED FLOOR PANEL PER SRM 53-42-12-860.SDR DALA108773260Support · corrodedDURING M-CHECK FOUND CORROSION ON AFT FUSELAGE SHEAR PLATE SUPPORT RT SIDE BETWEEN FR69-FR70. REPAIRED PER SRM 51-42-11.SDR DALA108713260Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL 261AB. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D25-37498.SDR DALA108703260Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL 261DF. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D25-37498.SDR DALA108693206Floor Panel · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR PANEL 262FF. REPAIRED PER SRM 51-72-00.SDR DALA108423260Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM AT Y254 FR20. REPAIRED IAW 53-11-14 FIG 201, 51-44-11, 51-42-11, 51-75-12.SDR DALA108443260Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM AT Y765 FR20. REPAIRED IAW 53-11-14 FIG 105, 51-44-11, 51-42-11, 51-75-12.SDR DALA108433260Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM Y1292 FR66 & FR68. REPAIRED IAW SRM 51-42-11, 51-74-00, 53-41-15, 51-44-11.SDR DALA108413260Sill · corrodedDURING M-CHECK FOUND CORROSION ON L2 DOOR SILL AT FR66 & FR68 PREVIOUS REPAIR. REPAIRED IAW SRM 51-42-11, 53-41-14, 51-44-11, 51-75-12.SDR DALA108233260Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR SUPPORT BEAM +Y1292 FR66. REPAIRED IAW SRM 51-42-11, 53-21-11.
Back to N360NW