N369NW
Service difficulty reports · 222
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N369NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N369NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2016110108095Battery Pack · inoperativeCABIN EMERGENCY ROW EXIT LIGHTS AND EMERGENCY ISLE LIGHTS ILLUMINATED W/EMER EXIT LIGHT SWITCH IN AUTO. ONLY SOME LIGHTS ILLUMINATED MIDDLE OVERHEAD EXIT SIGN AND EXIT SIGNS AT 1., 1R, 2L/2R ILOLUMINTED. SOME PATHWAY LIGHTS ALSO, REPLACED EPSU 12WL W/O BATTERYSDR DALA2016102807846Relay · inoperativeEMERGENCY EXIT LIGHTS OVERWINGS ON - OFF DURING FLIGHT. STOPPED THEN OFF & ON AFTER LANDING, REPLACED THE RELAY 8WL ON 103VU.SDR DALA2016092806923Skin · crackedLEFT AILERON UPPER SKIN CRACKED. REPAIRED PER ERA 549842-14SDR DALA2016051503975Skin · damagedCORROSION FOUND ON WING CENTER TANK TOP SKIN EXTERNAL SURFACE BETWEEN FRAME 42 AND STR 16, RIB 1 DATUM AND 1292. PERMANENT REPAIR ON UPPER SKIN BETWEEN FRAME 41 TO FRAME 42 AND 1292 TO 1732 PASSENGER CABIN ON CENTER WING BOX IAW ERA 546005-14AD REVISION ORIGISDR DALA2016051703976Web · corrodedCORROSION FOUND ON CENTER FUSELAGE LT SIDEBOX SHELL UPPER PLATE WEB PANEL BETWEEN FRAME 42-43, PERMANENT REPAIR ON SIDE BOX UPPER SURFACE BETWEEN FRAME 42 AND FRAME 43 LT SIDE IN PASSENGER CABIN IAW PRI 546001-14, REV 0 AND ER/A 546001-14, REV B.SDR DALA2016051103871Seat Track · corrodedCORROSION ON SEAT TRACK -765 FOUND OUT LIMITS IN PASSENGER CABIN FROM FRAMES 12 - 24, REPLACED THE SEAT TRACK IAW SRM 51-72-11 AND DWG D53110900 AND D53110984.SDR DALA2016051003870Shear Tie · corrodedCORROSION ON SHEAR TIE FRAME 31 BETWEEN STR 40 - 42R IN FWD CARGO BAY. REPLACED THE SHEAR TIE IAW SRM 51-72-11 AND DWG NR D53231712 AND D53231586.SDR DALA2016050703768Floor Support · corrodedCORROSION ON FLOORBEAM 1292 LOCATED BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA, REPLACED FLOORBEAM 1292 LOCATED BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWGS D53112812 AND D53110900.SDR DALA2016050603767Web · corrodedCORROSION ON WEB ON FLOOR STRUCTURE AT LEVEL STR 23L, FRAME 20 AT FWD GALLEY AREA, REPLACED WEB ON FLOOR STRUCTURE AT LEVEL STR 23L, FRAME 20 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112784.SDR DALA2016050603766Web · corrodedCORROSION ON WEB ON FLOOR STRUCTURE AT LEVEL STR 23R AND FRAME 20 AT FWD GALLEY AREA REPLACED WEB ON FLOOR STRUCTURE AT LEVEL STR 23R AND FRAME 20 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112784.SDR DALA2016050503765Floor Support · corrodedCORROSION ON LOWER SILL LOCATION FRAME 66 TO FRAME 68 RT SIDE AT AFT GALLEY AREA . REPLACED LOWER SILL LOCATED FRAME 66 TO FRAME 68RT SIDE AT AFT GALLY AREA IAW SRM 51-72-11 AND DWG D53480019.SDR DALA2016050503764Floor Support · corrodedCORROSION ON FLOORBEAM 1162 BETWEEN FRAME 68 TO FRAME 69 AT AFT GALLEY AREA. REPLACED FLOOR BEAM 1162 BETWEEN FRAME 68 TO FRAME 69 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472780.SDR DALA2016050503763Floor Support · corrodedCORROSION ON LOWER SILL LOCATION FRAME 66 TO 68 LT SIDE AT AFT GALLEY AREA, REPLACED FLOOR SILL LOCATION FRAME 66 TO 68 LT SIDE AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480019.SDR DALA2016050503762Floor Support · corrodedCORROSION ON FLOORBEAM 1162 BETWEEN FRAME 68 TO FRAME 69 AT AFT GALLEY AREA. REPLACED FLOORBEAM 1162 BETWEEN FRAME 68 TO FRAME 69 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472780 MEASURES OF REWORKED AREA: L=5.054", W=2.132", D=0.041".SDR DALA2016050503761Floor Support · corrodedCORROSION ON FLOOR SUPPORT 1589, FRAMES 65 TO 66 IN AFT GALLEY. REWORKED AND EVALUATED OUT OF LIMITS IAW SRM 53-00-14, TABLE 101, PARA 4.B, FIG 102, SHEET 1. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53474250.SDR DALA2016050503760Floor Support · corrodedCORROSION ON FLOOR SUPPORT 1589 BETWEEN FRAMES 65 TO 66 AT AFT GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53474250.SDR DALA2016050503759Floor Support · corrodedCORROSION ON FLOORBEAM 1225 BETWEEN FRAME 66 TO FRAME 68 AT AFT GALLEY AREA L=1.256", W=0.978", D=0.004". REPLACED FLOORBEAM 1225 BETWEEN FRAME 66 TO FRAME 68 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472780, MEASURES OF REWORKED AREA: L=1.790", W=1.18SDR DALA2016050403758Floor Support · corrodedCORROSION ON FLOORBEAM 465, FRAME 64 TO FRAME 66 AT AFT GALLEY AREA L= 1.300", W=0.786", D=0.005". REPLACED FLOORBEAM 465 LOCATED, FRAME 64 TO FRAME 67+10 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472816; MEASURES OF CORROSION ARE L=1.315", W=1.000", D=SDR DALA2016050403757Fitting · corrodedCORROSION ON CORNER FITTING FRAME 68 LT SIDE AT AFT GALLEY AREA. REPLACED CORNER FITTING FRAME 68 LT SIDE AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480019.SDR DALA2016050303593Floor Support · corrodedCORROSION ON FLOORBEAM +1292 LOCATION BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA, REPLACED FLOORBEAM +1292 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53110920.SDR DALA2016043003586Frame · crackedCRACK SECTION FRAME 68 AND STR 23L ON CROSSBEAM AT AFT GALLEY AREA, REPLACED SECTION FRAME 68 LOCATED AT STR 23L ON CROSSBEAM AT AFT GALLEY AREAS IAW SRM 51-72-11, SRM 51-42-11, D53474250, MEASURES OF CRACK IS L=0.350".SDR DALA2016043003585Floor Support · corrodedCORROSION ON FLOORBEAM -Y765, LOC FR 66 TO FR 70 AT AFT GALLEY AREA, L=2.500", W=1.500", D=0.005, REPLACED FLOORBEAM 765 LOCATED BETWEEN FRAME 66 TO FRAME 70 AT AFT GALLEY AREA SRM 51-72-11, DWS D53472093 AND D53472780, REWORKED AREA MEASURES L=1.931", W=1.33SDR DALA2016042903453Floor Support · corrodedCORROSION ON FLOORBEAM 254 LOCATED BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA, REPLACED FLOORBEAM 254 LOCATED BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53110984.SDR DALA2016042603443Floor Support · corrodedCORROSION ON FLOOR SUPPORT -254 BETWEEN FRAMES 16 TO 20. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53111461.SDR DALA2016042303183Dummy Rail · corrodedCORROSION ON RAIL DUMMY Y503.2 BETWEEN FRAME 12 TO FRAME 16 AT FWD GALLEY AREA. REPLACED RAIL DUMMY Y503.2 LOCATED BETWEEN FRAME 12 TO FRAME 16 AT FWD GALLEY ARE AS IAW SRM 51-72-11 AND DWG D53112825.SDR DALA2016040102631Power Supply · inoperativeFWD LT EMERGENCY LIGHTS PSU FAILED SELF TEST, UNIT FAULT LIGHT ON. REPLACED EPSU IAW AMM 33-51. TEST PASSED. OPS NORMAL.SDR DALA2016031602064Stringer · corrodedCORROSION ON STRINGER 43L BETWEEN FRAMES 56-57. R & R BAD PORTION OF S43L BETWEEN FR 55 AND 58 IAW SRM 53-00-13, FIG 201.SDR DALA2016031702065Connector · looseEMERGENCY LIGHTS INOPERATIVE ON SEAT ROWS 5, 7, AND 22, FOUND LOOSE CONNECTOR AT SEAT 7 AND 22. REPLACED LIGHT ASSY AT ROW 5.SDR DALA2014121006485Wire Harness · unsecureDURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHT WIRE HARNESS UNSECURED ON SEAT ROWS 6AB AND 7 AB. MAINTENANCE SECURED EMERGENCY LIGHT WIRE HARNESS AT SEAT ROWS 6AB AND 7 AB AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA14004803269Connector · looseDURING INSPECTION, FOUND SEAT ROW 2AB EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE FOUND LOOSE CONNECTOR. SECURED CONNECTOR AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA13051103269Connector · failedDURING APPROACH FOR LANDING AND AFTER COMMANDING FLAPS 2 DEG, 30 SEC LATER FLT/CTL FLAPS FAULT APPEARED ON THE UPPER ECAM SCREEN. CREW FOLLOWED QRH PROCEDURE, DECLARED EMERGENCY AND LANDING WAS UNEVENTFUL. MAINTENANCE REPLACED CONNECTOR 7541VC, 7505VC, 7543VSDR DALA12013963269Battery · inoperativeDURING EMERGENCY LIGHTS TEST, FOUND EPSU BATTERY PACK RT MESSAGE. APPLIED TSM 33-51-00-810-802A. PERFORMED OPS TEST OF THE EMERGENCY LIGHT SYS. FAULT CONTINUES. PERFORMED OPS TEST OF THE BATTERY PSEU. BATTERY FAULT APPEARS. R & R BATTERY IAW AMM 33-51. TESDR DALA12011953269Epsu · failedDURING SERVICE CHECK, FOUND LEFT ESPU BATTERY FAIL TEST. MX REPLACED LT ESPU AND FUNCTIONAL CHECKED NORMAL.SDR DALA12006443269Light · looseDURING NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT SEAT 1B INOPERATIVE. MAINTENACE SECURED LIGHT ASSEMBLY AND FUNCTIONAL CHECKED NORMAL.SDR DALA12002383269Battery Pack · inoperativeEMERGENCY LIGHT TEST FAULTS EPSU BATTERY FORWARD LEFT. REMOVED AND REPLACED BATTERY PACK AT 10WL L-1 DOOR PER AMM 33-51-58. NOW TESTED GOOD.SDR DALA12001893269Lamp · inoperativeDURING NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT SEAT 1B INOPERATIVE. MAINTENANCE REPAIRED ASSEMBLY AND RELAMPED. OPERATIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA12001793269Structure · dentedNR 2 LEFT MAIN ENTRY DOOR DENTED AT LOWER AFT CORNER. MAINTENANCE REMOVED DAMAGE AND FABRICATED REPAIR PARTS PER ERA 504635-14 REV O. PERFORMED DETAILED VISUAL INSPECTION. NO FURTHER DAMAGE NOTED. INSTALLED REPAIR AND RESTORED ACCESS PER SECT 2 PERM REPAIRSDR DALA1204283269Epsu · inoperativeDURING NON ROUTINE CHECK, FOUND THE EMERGENCY LIGHT SYSTEM TEST FAULTS "EPSU EXIT LOAD L". MAINTENANCE REPLACED LT EPSU AND BATTERY PACK. FUNCTIONAL CHECK WAS NORMAL AND AIRCRAFT RETURNED TO SERVICE.SDR DALA1135023269Wire · brokenDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY ESCAPE PATH LIGHT ON SEAT 5C AND 6C INOPERATIVE. MAINTENANCE RECONNECTED BROKEN WIRE AND FUNCTIONAL TEST WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1134053269Power Supply · faultedDURING A NON ROUTINE CHECK, FOUND THE EPSU FAULTED FOR THE RIGHT AND LEFT EMERGENCY LIGHTS. MAINTENANCE REPLACED THE EPSU AND FUNCTIONAL TEST WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1122863269Connector · looseDURING EMERGENCY LIGHT TEST FOUND SEAT ROW 4B INOP. LOOSE CONNECTOR SECURED AND TESTS OK.SDR DALA1122853269Connector · looseDURING EMERGENCY LIGHT TEST FOUND SEAT ROW 6C INOP. LOOSE CONNECTOR SECURED AND TESTS OK.SDR DALA1103573269Power Supply · inoperativeDURING NON A ROUTINE CHECK, FOUND THE EMERGENCY LIGHT AT L2 DOOR INOPERATIVE. MX REPLACED THE POWER SUPPLY AND LIGHT ASSY. FUNCTIONAL CHECK WAS NORMAL AND ACFT WAS RETURNED TO SERVICE.SDR DALA1051893269Connector · unsecureDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT SEAT 5C AND 8C INOPERATIVE. MX RESECURED WIRING CONNECTORS AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED SERVICE.SDR DALA1022023269Connector · disconnectedPILOT REPORTED EMERGENCY PATH LIGHT AT SEAT 5C INOP, SECURED CONNECTOR AND CHECKS OK.SDR DALA1017613269Skin · dentedDURING M-CHECK FOUND RIGHT FUSELAGE SKIN DENTED AT FR3. REPAIRED PER ERA 483384-14 & SRM 51-42-11.SDR DALA1017593269Support · corrodedDURING M-CHECK FOUND CORROSION ON AFT CABIN RT FRAME SUPPORT BETWEEN FR69 & FR70. REPAIRED PER SRM 51-42-11 & SRM 51-44-11.SDR DALA1017583269Sill · corrodedDURING M-CHECK FOUND CORROSION ON R2 DOOR SILL AT FR 66. REPAIRED PER ERA 483379-14.SDR DALA1017603269Fitting · corrodedDURING M-CHECK FOUND CLEAT CORRODED AT FR33 BETWEEN S41L & S42L. REPAIRED PER SRM 51-42-11 & SRM 51-44-11.SDR DALA1017173269Support · corrodedDURING M-CHECK FOUND CORROSION ON AFT CABIN LT FRAME SUPPORT AT +Y1732 BETWEEN FR69 & FR70. REPAIRED PER SRM 51-42-11.