What was found
CORROSION ON WEB ON FLOOR STRUCTURE AT LEVEL STR 23L, FRAME 20 AT FWD GALLEY AREA, REPLACED WEB ON FLOOR STRUCTURE AT LEVEL STR 23L, FRAME 20 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112784.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON WEB ON FLOOR STRUCTURE AT LEVEL STR 23L, FRAME 20 AT FWD GALLEY AREA, REPLACED WEB ON FLOOR STRUCTURE AT LEVEL STR 23L, FRAME 20 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112784.