N371NW
Service difficulty reports · 185
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N371NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N371NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA12009813271Floor Panel · damagedDURING INSPECTION, FOUND AFT CABIN FLOOR PANEL 261FF DAMAGED. REPLACED FLOOR PANEL IAW SRM 5172-11.SDR DALA12009803271Floor Panel · delaminatedDURING INSPECTION, FOUND FWD CABIN UTILITY FLOOR PANEL 232DF IS DELAMINATED. FABRICATED FLOOR PANEL IAW DWG 3D25-37498.SDR DALA12009793271Floor Panel · damagedDURING INSPECTION, FOUND FWD CABIN FLOOR PANEL 221DF HAS DAMAGED INSERT. FABRICATED FLOOR PANEL IAW DWG 3D25-37498.SDR DALA12009783271Floor Panel · damagedDURING INSPECTION, FOUND CTR CABIN FLOOR PANEL 242FF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW DWG 3D25-37498.SDR DALA12009773271Floor Panel · damagedDURING INSPECTION, FOUND AFT CABIN FLOOR PANEL 261BG HAS DAMAGED EDGE. FABRICATED FLOOR PANEL IAW DWG 3D25-37498. DAMAGE DIM. L=2.0" W=1.0".SDR DALA12009743271Floor Support · corrodedDURING INSPECTION, FOUND AFT B UTILITY LT DOOR SILL HAS CORROSION ON FLOOR SUPPORT SECTION AT FR66. LT AFT DOOR SILL REPAIR AT FR66 HAS BEEN ACCOMPLISHED IAW ER/A 506755-14, REV ORIG SECTION I PERMANENT REPAIR & SRM 53-41-14 FIG 201 REPAIR PRINCIPLE 6. THIS SDR DALA12009593271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY -Y1292 FLOOR SUPPORT BETWEEN FR 66 AND 68 HAS CORROSION AROUND FASTENERS AND FASTENER HOLES. REMOVED CORROSION IAW SRM 51-74-00. ORIG MAT .087" DAMAGE " W=0.3" =.037" FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15, FIG 1. RSDR DALA12009583271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY -Y1292 FLOOR SUPPORT BETWEEN FR 64 AND 66 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 AND WAS FOUND TO BE OUT OF LIMIT. REPLACED FLOOR SUPPORT IAW TO SRM 51-42-11.SDR DALA12009573271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY -Y1292 FLOOR SUPPORT BETWEEN FR 69 AND 69 IS CORRODED AROUND FASTENERS. REMOVED CORROSION IAW SRM 51-74-00. ORIG MAT .157" DAMAGE DIM L=1.9" W=0.7" D=.051" FOUND TO BE OUT OF LIMITS IAW TRM53-41-15, FIG 1. REPLACED FLOOR SDR DALA12009473271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY Y1292 FLOOR SUPPORT HAS EXFOLIATION AROUND HARD POINT MOUNT HOLE BETWEEN FR 64 AND FR 66. REPLACED FLOOR SUPPORT AT FR 64- FR 66 Y1292 IAW SRM 51-42-11. ORG MAT. .087" MAT LOSS L=4.0" W=1.5" D=.087" FOUND TO BE OUT OF LIMISDR DALA12009463271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY Y1292 FLOOR SUPPORT HAS CORROSION AROUND FASTENER HOLES AND UPPER SURFACE BETWEEN FRAME 66 AND 68. REPLACED FLOOR SUPPORT AT FR 66 - FR 68 Y1292 IAW SRM 51-42-11, ORG MAT .087" MAT. LOSS L=1.0" W=1.0" D=.036". FOUND TO BESDR DALA12009453271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY Y1292 FLOOR SUPPORT HAS CORROSION AROUND FASTENERS AND FASTENER HOLES BETWEEN FR 68 AND 70. SSI 534147.NR 260-83. REPLACED FLOOR SUPPORT AT FR 68 AND 70 Y1292 SRM 51-42-11, ORG MAT .157" MAT.LOSS L=1.0 W=1.0 .064 FOUND TO SDR DALA12009433271Web · corrodedDURING INSPECTION, FOUND AFT UTILITY RT SIDE WEB BETWEEN FR 68 AND FR 69 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. L=0.5", W=0.5", D=0.020". NO ALLOWABLE LIMITS FOUND IN SRM. REPLACED SHEAR TRAY IAW SRM 51-42-11.SDR DALA12009563271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY -Y465 FLOOR SUPPORT HAS 4 AREAS WITH HEAVY CORROSION BETWEEN FR 64 AND 67. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS AFTER REWORK. ORIG MAT. .149" DAMAGE DIM. L=1.1" W=1.0" D=.040" IAW SRM 53-00-14, SDR DALA12009293271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY -Y765 FLOOR SUPPORT HAS 4 LARGE AREAS OF EXFOLIATION BETWEEN FR66 AND 70. BLENDED AREA IAW SRM 51-74-00, DIM OF BLENDOUT AREA, ORIGINAL MAT. 0.157" L=1.25" W=1.1" D=0.065 FOUND TO BE OUT OF LIMITS IAW SRM 53-41-15, FIG 1SDR DALA12009283271Sill · corrodedDURING INSPECTION, FOUND R2 DOOR CUT OUT CENTER SHAPE SILL CORRODED. REMOVED CORROSION IAW SRM 51-74-00. DIMENSION OF REWORKED AREA ORIGINAL MAT. 0.100 L=1.65" W=0.600" D=0.030" NO ALLOWABLE DAMAGE FOUND IN THE SRM. REPLACED SHAPE SILL IAW SRM 51-42-11.SDR DALA12009303271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FR 20 FLOOR SUPPORT -Y765 HAS CORROSION. BLENDED CORROSION IAW SRM 51-74-00.L=2.0 W=1.060 D=0.079. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14 REPLACED FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12009203271Shear Plate · corrodedDURING INSPECTION, FOUND AFT UTILITY RT SHEAR PLATE SUPPORT BETWEEN FR69 AND FR70 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00, DIM OF BLENDED OUT ARE: L= 1.5" W=1.0" D=0.020" NO ALLOWABLE LIMITS FOUND IN SRM. REMOVED DAMAGED SHEAR PLATE SUPPORT IAW SRM 51-SDR DALA12009193271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FR20 FLOOR SUPPORT WEB -Y1732 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. BLEND SIZE:L=3.0" W=1.5" D=.035".NO LIMIT ON SRM. REPLACED FLOOR SUPPORT (WEB) PN D5311278520301 IAW SRM 51-42-11, SRM 51-SDR DALA12009183271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA BTW FR16 - FR21 FLOOR SUPPORT -Y254 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00(6PLS) BLEND SIZE 2"W X 6 "L X .025"D, 2.5"L X 2"W X .028"D, 3"L X 1.4"W X .012"D, 2.8"L X 1.2"W X .013"D, 1.3" X .8"X .0SDR DALA12009153271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FR16 -FR20 FLOOR SUPPORT Y1292 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14. REMOVED FLOOR SUPPORT IAW SRM 51-42-11. LOCATED & DRILLED NEW FLOOR SUPPORT IAW SRSDR DALA12009073271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FR16 FLOOR SUPPORT Y940 HAS CORROSION. BLENDED FLOOR SUPPORT IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 106, REPLACED WITH NEW FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12009063271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FR 20 FLOOR SUPPORT Y765 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14. R & R FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12009053271Floorbeam · corrodedDURING INSPECTIONS, FOUND AFT UTILITY Y765 HAS CORROSION AROUND HARD POINT MOUNT HOLE ABOVE FR66. REMOVED CORROSION IAW SRM 51-74-00 FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15 FIG 1. REPLACED FLOORBEAM IAW SRM 51-42-11.SDR DALA12009043271Floor Support · corrodedDURING INSPECTIONS, FOUND MAIN CABIN FWD UTILITY AREA, FR 16-21 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. FOUND OUT OF LIMITS IAW SRM 53-11-14, FIG 106. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12009033271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA BETWEEN FR 16-21 FLOOR SUPPORT HAS SEVERAL CORROSION. BLENDED DAMAGED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 102, REMOVED DAMAGED FLOOR SUPPORT IAW SRM 51-42-11, INSTALLED NSDR DALA12009143271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FLOOR SUPPORT CORRODED. BLENDED CORROSION IAW SRM 51-74-00. FOUND OUT OF LIMITS IAW SRM 51-11-14 FIG 103. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12009133271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY FLOOR SUPPORT HAS CORROSION. BLENDED AREAS IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15 FIG 1. REMOVED DAMAGED FLOOR SUPPORT IAW SRM 51-42-11. INSTALLED NEW FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12008913271Floor Support · corrodedDURING INSPECTIONS, FOUND MAIN CABIN UTILITY AREA BTW FR 20-21 FLOOR SUPPORT -Y189 HAS CORROSION. BLENDED AREA L=2.0"W=1.0"& 0.150" FOUND OUT OF LIMITS IAW SRM 53-11-14. R & R FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA1170603271Wire · brokenDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT 8 INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1119923271Connector · unsecureDURING EMERGENCY LIGHT TEST FOUND SEAT 7C PATH LIGHT INOP. SECURED CONNECTOR AND TESTS OK.SDR DALA105363271Wire Harness · damagedDURING TEST FOUND EMERGENCY AISLE LIGHT 23C INOP, WIRING HARNESS WAS REPLACED AND CHECKED OK.SDR DALA103693271Wire · brokenDURING A NON ROUTINE CHECK, FOUND EMERGENCY LIGHT AT ROW 1 & 2 INOPERATIVE. MX REPAIRED BROKEN WIRE AND OPS CHECK WAS NORMAL.SDR DALA100783271Wire · looseDURING A NON ROUTINE CHECK, FOUND EMERGENCY ESCAPE PATH LIGHT AT ROW 23 INOPERATIVE. MX RECONNECTED LOOSE WIRE AT LIGHT ASSY. OPS CHECK WAS GOOD.SDR NWAA071173271Battery Pack · inoperativeDURING EMERGENCY LIGHT CHECK, FOUND RIGHT EMERGENCY EPSU BATTERY INOP. REPLACED RIGHT EMERGENCY EPSU BATTERY, OPERATES GOOD.
Back to N371NW