What was found
DURING INSPECTION, FOUND AFT UTILITY RT SHEAR PLATE SUPPORT BETWEEN FR69 AND FR70 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00, DIM OF BLENDED OUT ARE: L= 1.5" W=1.0" D=0.020" NO ALLOWABLE LIMITS FOUND IN SRM. REMOVED DAMAGED SHEAR PLATE SUPPORT IAW SRM 51-42-11. INSTALLED NEW SHEAR PLATE SUPPORT IAW SRM 51-42-11.