N37263
Service difficulty reports · 66
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N37263' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N37263' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026092919981Light · inoperativeCABIN LIGHTS , OPS CHECK PROCEDURE, SIDEWALL WINDOW LIGHT AT EMERGENCY EXIT ROW 21ABC INOPERATIVE. REMOVED AND REPLACED EMERGANCY EXIT ROW 21ABC WINDOW LIGHT. OPS CHECK GOOD. IAW AMM 33-21-00-960-807.SDR CALA2026083119038None · noneF/A REPORTS FUNNY ODOR FROM LAV E, POSSIBLE PASSENGER SMOKING ON ACFT IN LAVATORY. CIGARETTE BUTT FOUND IN LAVATORY. PREFORMED SMOKE DETECTOR TEST IAW AMM 26-14-00. OPS CHECK GOODSDR CALA2026081218506Striker · wornSTRIKER PLATE AROUND 192DR STRUCTURE IS MISSING. EVALUATED DAMAGE FOUND TO BE PREVIOUSLY REPAIRED, REPAIR STRAP FOUND TO BE WORN THROUGH. REMOVED PREVIOUS REPAIR STRAP IAW SRM 51-40-02. FOUND PREVIOUS FILLER RADIUS TO BE TOO SMALL, ENLARGED CUTOUT RADIUS FORSDR CALA2026013013448Water Line · burstPOTABLE WATER LINE BURST IN THE AFT CARGO BAY, AFT BULKHEAD. LINE CONNECTS TO POTABLE WATER TANK. FLOOR PANELS REMOVED IAW AMM 25-52-10-000-801, OZONE WATER CART LIQUID SPILL DETERMINED TO BE NON-HAZARDOUS IAW EC/RA 2011-01000, AFFECTED SPILL AREA BS 727+4 - SDR CALA2026012313234Panel · damagedDURING WALK AROUND, FOUND PANEL ON RT WINGLET MISSING PARTS, PSDR CALA2025092509262Anti-Ice Valve · faultedENGINE COWL ANTI-ICE LIGHT ON AT 60KTS, ABORTED TAKEOFF, LIGHT WENT OUT 160.1 POWER WAS PULLED BACK AND LIGHT WENT OFF. CREW UNABLE TO SAY WHICH SYSTEM HAD THE AMBER LIGHT ILLUMINATED. CREW REPORTED UNABLE TO TELL WHICH SIDE, MAYBE RT BUT BOTH PILOTS UNABLESDR CALA2025070306170Light · damaged(EPL) INSPECTION -ROW 22 EMERGENCY LIGHT DAMAGED. REMOVED AND REPLACED LIGHT WITH NEW ROW 22 EMERGENCY LIGHT CMM 25-23-54-4676.SDR CALA2025062005745Elec Connector · unsecureROW 7 AISLE SEAT EMERGENCY EXIT LIGHT INOP. FOUND POOR CONNECTION UNDER MIDDLE SEAT. CLEANED AND RESEATED CONNECTION, OPS CHECK GOOD.SDR CALA2025060405255Battery Pack · dischargedEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - RIGHT OVERWING EXIT LIGHT SIGNS DO NOT TURN ON DURING OP CHECK. REMOVED AND REPLACED BATTERY PACK FOR RIGHT OVERWING EXIT LIGHT SIGNS. OPS CHECKS GOOD. REF AMM 33-51-06-960-804.SDR CALA2025022000397Window Frame · crackedDURING THE ACCOMPLISHMENT OF THE WINDOW FRAME E-F REPAIR PER EA5 310-08195 REV. AOP 001 AT AAR-RFD, A CRACK WAS FOUND IN THE 3RD LOWER CORNER FASTENER HOLE OF THE LEFT HAND #3 WINDOW FRAME (P/N 141A8831-7). THE SUBSEQUENT CRACK REMOVAL PROCESS RESULTED IN A HOSDR CALA2025021000328Skin · crackedLH HORIZONTAL STABILIZER LOWER SKIN, ONE (1) CRACK FOUND AT STA 147.9 LOCATED AT 17 INCHES FROM TRAILING EDGE (REF: AAR NR 1000029021)SDR CALA2025022000399Battery Pack · no testPASSENGER CABIN, EMERGENCY LIGHT BATTERY PACK M1675 FAILS CAPACITY CHECK (REF: AAR NR 1000028948) REMOVED AND REPLACED EMERGENCY BATTERY PACK M1675 IAW B737 AMM 33-51-06-960-805. OPS TEST GOOD.SDR CALA2025022000392Battery Pack · no testPASSENGER CABIN, EMERGENCY LIGHT BATTERY PACK M1694 FAILS CAPACITY CHECK (REF: AAR NR 1000028949) REPLACED PASSENGER CABIN, EMERGENCY LIGHT BATTERY PACK M1694 IAW B737 AMM 33-51-06-960-805. OPS CHECK GOOD. (WORK ACCOMPLISHED BY V934137 AND AAR QC A-15 V931575)SDR CALA2024122401643Anti-Ice Valve · faultedENG ANTI ICE CAUTION LIGHT ON T/O REJECT T/O AT 50KTS RESET BOTH ENGINES CB,S. RAN BOTH ENGINES AND PERFORMED ENGINE COWL TAI VALVE OPERATIONAL TESTS. BOTH GND CHK OK PER AMM 30-21-11-860-009 .SDR CALA2024110601057Monitor · unknown1B SEATBACK UNUSUALLY WARM OPPOSITE 2B VIDEO MONITOR NO BURNING SMELL AND MARK, NO MARK OF ANY SMOKE . SEAT 2B MONITOR IS COOLER THAN SEAT 2A MONITOR. PERFORMED SEAT 2B MONITOR OPS CHECK FOUND GOOD IAW AMM 44-25-00.SDR CALA2024100302548Battery Pack · inoperativeLEFT AFT OVERWING EXIT LOWER EMERGENCY LIGHT INOPERATIVE.SUPPORT TASK NSA EMX N/R 00215. REMOVED AND REPLACED BATTERY PACK AND EMERGENCY LIGHTS OPS CHECKS GOOD.SDR CALA2024100302547Battery Pack · inoperativeR AFT OVERWING EXIT LOWER AND UPPER EMERGENCY LIGHT INOPERATIVE SUPPORT TASK EMX NR 00216. REMOVED AND REPLACED BATTERY PACK AND EMERGENCY LIGHT OPS CHECK GOOD.SDR CALA2024100302549Connector · damagedAPPROXIMATELY 19 CONNECTORS FOR THE EEPL SEAT HARNESSES WERE FOUND BROKEN DURING THE INTIAL REMOVAL OF SEATS FROM CABIN. SUPPORT TASK NSA EMX N/R 00050. REMOVED AND REPLACES CONNECTORS FOR CABIN SEAT EEPL HARNESS THROUGH THE CABIN AS REQUIRED AND EMERGENCY LIGSDR CALA2024100302546Battery Pack · weakAFT R/H EMERGENCY BATTERY PACK FOUND TO BE WEAK.SUPPORT TASK NSA EMX N/R 00154. REMOVED AND REPLACED BATTERY PACK AND EMERGENCY LIGHTS OPS CHECKS GOOD.SDR CALA2024100302545Battery Pack · weakAFT L/H EMERGENCY BATTERY PACK FOUND TO BE WEAK. SUPPORT TASK NS A EMX N/R 00155. REMOVED AND REPLACED BATTERY PACK AND EMERGENCY LIGHTS OPS CHECKS GOOD.SDR CALA2024010400021Lamp · inoperativeDURING OUTBOUND PVI FOUND EMERGENCY SLIDE LIGHT AFT OF R1 DOOR EXTERIOR INOP.SUPPORT TASK NSA EMX N/R 00149. REMOVED AND REPLACED R1 DOOR EMERGENCY SLIDE LIGHT LAMP AND OPS CHECK GOOD IAW UAL B737 AMM 33-51-- 04-960-801.SDR CALA2024010200012Bulb · burned outDURING OPS CHECKS R-1 DOOR EXT SLIDE LIGHT WAS INOP. R&R R-1 DOOR EMERGENCY SLIGHT LAMP AND OPS CHECKS GOOD IAW B737 AMM 33-51-04-960-801.SDR CALA2023120803601Fitting · crackedB737-57-4-1262 SHEAR FITTING AT STATION 540 AND LBL 15.04 IS CRACKED SUPPORT TASK NSA EMX NR 00093 REMOVED AND REPLACED SHEAR FITTING AT STATION 540 AND LBL DATA WAS TRANSCRIBED FROM NSA EMX N/R 00093, AND HANGAR 15.04 IAW 5737-800 SRM 51--40-02 AND BAC DWG 11SDR CALA2023120803597Fitting · crackedB737-57-4-1262 SHEAR FITTING AT STATION 540 AND RBL 15.04 IS CRACKED SUPPORT TASK NSA EMX NR 00094 REMOVED AND REPLACED SHEAR FITTING AT STATION 540 AND RBL DATA WAS TRANSCRIBED FROM NSA EMX N/R 00094 AND HANAGR N/R 15.04 IAW B737-800 SRM 51--40-02 AND BAC DWGSDR CALA2023052201591Controller · faultedPRESS AUTO FAIL AND ALT NOT WORKING FAULTS WHEN TURNED ON AND FAULT CODE 059 REMAINS. ON INTIAL BOTH CABIN CONTROLLERS WERE FAULTING.DIDNT COMPLETE AFTER MOVING FROM MANUAL TO AUTO TO ALTN.NO EXISTING FAULTS. REF FIM TASK 21-31 TASK 824. FOUND CABIN PRESSURE SDR CALA2023030100592Motor · noneCREW REPORTS DIFFICULTY REPOSITIONONG HORZ STAB. ACTUATOR. THE HORIZONTAL STABILIZER DOES NOT OPERATE ELECTRICALLY. WHEN ATTEMPTING TO MOVE STAB MANUALLY STAB CONTROL WHEEL IS DIFFICULT TO MOVE AND A RATCHING SOUND CAN BE FELT IN THE CONTROL WHEEL AND HEARD ISDR CALA2022122103455Relay · failedSTAB OUT OF TRIM LIGHT LIGHT ON MAIN ELECTRIC AND AUTO PILOT STAB TRIM FAIL. STAB OUT OF TRIM L IGHT SPEED TRIM FAIL LIGHTS ILLUMINATED. PLACED MAIN ELECTRIC AND AUTO PILOT TO CUTOFF AND USED MANUAL TRIM TO RETURN TO EWR. VERBAL FROM CREW. RIGHT AFTER TAKE OFSDR CALA2022102702949Light · damagedRED SEAT MOUNTED EMERGENCY LIGHT AT SEAT 21ABC DAMAGED. REMOVED AND REPLACED RED EMERGENCY LIGHT REF MM 33-51-11. OPS CK OK. LIGHT IS OPERATIONAL. NO DISCREPANCIES NOTEDSDR CALA2022092102430None · corrodedSPEED TRIM FAIL MASTER CAUTION ON DEPT BOX. LAND VERIFY TEST AND STAB TRIM TEST ALL PASS ON THE GROUND. REF FIMTSK 22-11 TASK 849. CURRENT STATUS FAULT HISTORY FOR LAST LEG CURRENT FAULTS STAB TRIM CUTOUT RELAY R64 LOCATED IN JUNCTION BOX J4. NEED TO RPL DUE SDR CALA2022062001546Surge Valve · leaking263 1505-17 BZN-DEN DURING IRREGULAR FUELING OPERATION OF RT MAIN FUEL TANK DUE TO VTO ON MEL , THERE WAS A FUEL SPILL OUT OF RT WING TIP SURGE TANK VENT, LOCAL MAINTENANCE ESTIMATES FUEL SPILL WAS APPROXIMATELY 15 GALS. BZN FIRE DEPARTMENT ACCOMPLISHED CLEAN-SDR CALA2022060801448Skin · dentedSUPPORT TASK FWD CARGO DOOR SKIN DENTED 17" FROM FWD EDGE AND 12" FROM TOP MRASURED DENT AS 3.8 X 3 X .080. W/Y = 37 WITHIN ALLOWABLE LIM ITS PER SRM 52-30-01 ALLOWABLE DAMAGE 1 DETAIL F. INSTALLED DE NT DOT PER GMM 07-01-55 RE-INSPECTED DENT, NO PROGRESSIONSDR CALA2022060601432Battery Pack · dischargedEMERGENCY LIGHTS INOP (REF AAR RFD NR 99935413). REPLACED BATTERY PACK M1671 AT ROW 27DEF IAW B737 AMM 35-51-06-960-805. TEST GOOD. WORK ACCOMPLISHED BY AAR RFD TECH V937427 AND AAR QC A-50 V931572.SDR CALA2022050901170Bear Strap · crackedDURING NDT INSPECTION OF FWD GALLEY DOOR BEAR STRAP ON EA 5310-0 7694 REV A. A CRACK WAS NOTED ON THE INNER SURFACE OF THE BEAR S TRAP CRACK LENGHT MARKED ON SURFACE CRACK BETWEEN STRINGER 8R AND 9R BETWEEN STATION 291.5 AND 294.5 (REF AAR RFD NR 99935248) REQSDR CALA2022050601152None · corrodedFOUND POSSIBLE CORROSION ON UPPER FLOOR BEAM BEAM AT STA 986.5, BL 22.5R (REF AAR NR 99935093)SDR CALA2021051200641Door · leaking2L DOOR SQUEAL AND CBN NO PRESSURIZE UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. UPDATED MAA CODE FIX USING VENDOR MAA SCREEN UPDATED MAA CODE FIX USING VENDOR MAASDR CALA2021011500043Controller · failedAUTO FAIL LT FL320 ALTN COULD NOT CONTROL CABIN EMERGENCY DESCENT CREW STATES AUTO FAIL LIGHT CAME ON SWITCHED TO ALTERNATE, NO RESPONSE FROM VALVE SWITCHED TO MANUAL. MAINT CABIN PRESS CONT FAULT CONTROLLER LRU FAIL DISPLAYED ON CONTROLLER 1 AND 2, FAULT CODSDR CALA2019040100494Fuel Cell · leakingFUEL SMELL AIRBORNE THROUGHOUT CABIN. STRONGEST ODOR OVER WINGSDR CALA2019032200440Handle · frozenL1 DOOR EXTERIOR HANDLE WILL NOT PULL OUT FROZEN WITH ICE ICE THOWED OUT. HANDLE PULLS OUT OK NOW, INSPECTED HANDLE OK AMM 52-11-00-200-801, OPENED AND CLOSED WITH EXTERIOR AND INTERIOR HANDLE OK AMM 52-11-00-860-801/802/803/804.OKSDR CALA2018041801178Light · inoperativeEMERGENCY LIGHTS INOPERATIVE AT SEAT ROWS 7 - 14, 29 - 38, RT OVERWING EXITS AND RT AFT DOOR. FOUND BLOWN FUSES IN THE POWER SUPPLYS M1694, M1695, AND M1672. A BAD BATTERY AT M1676. REPLACED THE BATTERY CHARGERS M1694, M1695, M1672, AND REPLACED BATTERY AT SDR CALA2017050101215Lens · missingRIGHT AFT DOOR EMERGENCY EXIT LENS MISSING . SECURED THE LENS.SDR CALA2016042100238Frame · dentedFORWARD CARGO LT FRAME STATION 500E, JUST ABOVE SIDE PLATE THE FRAME IS SEVERELY DENTED ON TOP SIDE. IAW ECRA 5310-06802 COMPLIED WITH PART 1 INTERIM REPAIR. ITEM PLACED ON DIP IAW PART 1 STEP 17 OF ECRA 5310-06802.SDR CALA2015032000190Battery Pack · dischargedNO EMER LIGHTING FROM 29 AFT. FOR SDR REPORTING. R & R BATTERY PACK FOR POWER SUPPLY IAW AMM 33-51-06 -960-805. OPERATIONS CHECKED GOOD.SDR CALA2015022000110Connector · damagedEAT 15 ABC EMER LIGHT INOPERATIVE. R & R DAMAGED CONNECTOR AT SEAT ROW 15 ABC OTBD LEG. PN 172343-1 CONNECTOR. OPERATIONS CHECKED OF EMERG LIGHTING GOOD IAW AMM 33-51-00.SDR CALA2014111901453Adiru · malfunctionedCLIMBING THROUGH 250 FOR 260 AUTOPILOT DISCONNECTED & WE HAD AN IRS LIGHT ON MASTER CAUTION, WITH A FAULT LIGHT ON THE OVERHEAD LT IRS. COMPLETED QRH WITH NO CHANGE. PLACED ON NO AUTO LAND STATUS DUE TO RT IRU. R & R, NO TIME TO PERFORM RTS. STICKER INSTALSDR CALA2014050100539Brake · draggingBRAKE DRAGGING ON LT INBD MAIN MOUNT DURING TAKEOFF ROLL. FUSE PLUG BLOWN, REJECTED TAKEOFF AT 50 KTS. R & R NR 1 & NR 2 TIRES, BRAKES, AB & AS CONTROLLER, NR 1 & NR 2 ANTI-SKID VLVS & LT BRAKE UPPER & LOWER FUSES. ALL SYS CHECKED NORMAL. TAXIED ACFT, NO DESDR CALA2014031700337Lens · wrong partAFT CABIN WINDOW EMERGENCY EXIT PLACARDS REPORT MARKED INCORRECTLY WITHOUT ARROWS. REPLACED LENS FOR LT & RT AFT CABIN WINDOW EMERGENCY EXIT SIGNS IAW IPC 33-51-01 FIG 16.SDR CALA2013092600698Skin · crackedCOMPLETED C SCAN FOUND CRACK ON LT HORIZONTAL STAB LOWER SIDE AT STA 129.50 APPROXIMATELY 6 INCHES FWD OF PATCH, 16 INCHES AFT OF FWD SPAR. INSTALLED REPAIR IAW SRM 55-10-01 REPAIR 11.SDR 39NR20130903048Pressure Panel · crackedDURING INSPECTION OF VERTICAL PRESSURE WEB AT BS 663, FOUND .25 INCH CRACK AT RBL 41, WL 194. REPAIRED PRESSURE WEB IAW SRM 57-10-10, REPAIR 3, ALTERNATE 2, PAGE 204, FIGURE 204.SDR CALA2012031900195Oven · malfunctionedIN CRUISE LEAD F/A CALLED AND STATED THAT THERE WAS A STRONG SMELL IN AFT GALLEY THAT SMELLED LIKE ELEC WIRING OR PLASTIC BURNING. TURNED OFF OVEN AND COFFEEMAKER. RAN QRH. NO SMOKE ONLY SMELL. SMOKE DID NOT DISSIPATE. DECLARED EMERGENCY AND DIVERT TO ATLSDR CALA2011061000430Structure · crackedCABIN - CRACK AT STA 440, STRINGER 9R ACCOMPLISHED REPAIR AT STA 440 STR 9R REF EC/RA 5310-05385.
Back to N37263