N396DA
Service difficulty reports · 163
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N396DA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N396DA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2021042402372Trunnion · corroded(LOG 1788228) DURING INSPECTION FOUND LMLG FWD TRUNNION LUG MARKED 1A OUTER FACE CORRODED. REPAIRED PER B737 SRM 57-20-90 REP 2.SDR DALA2021042402371Trunnion · corroded(LOG 1788224) DURING INSPECTION FOUND LMLG FWD TRUNNION LUG MARKED 1A BORE CORRODED. REPAIRED PER B737 SRM 57-20-90 REP 2.SDR DALA2021042402370Trunnion · corroded(LOG 1788219) DURING INSPECTION FOUND LMLG FWD TRUNNION LUG MARKED 4D INNER FACE CORRODED. REPAIRED PER B737 SRM 57-20-90 REP 2.SDR DALA2021042402369Trunnion · corroded(LOG 1788218) DURING INSPECTION FOUND LMLG FWD TRUNNION LUG MARKED 4D BORE CORRODED. REPAIRED PER B737 SRM 57-20-90 REP 2.SDR DALA2021042402368Trunnion · corroded(LOG 1788215) DURING INSPECTION FOUND LMLG FWD UPPER I/B TRUNION LUG MARKED 2C, INNER FACE CORRODED. REPAIRED PER B737 SRM 57-20-90 REP 2SDR DALA2021030501292Battery Pack · inoperative(LOG 1743361) EMERGENCY BATTERIES FAILED OPS CHECK. R/R EMERGENCY BATTERIES @ EMERGENCY BATTERY CHARGERS AT M10673 AND M10671 PN D717-02-030 AND PN D717-02-001 RESPECTIVELY. OPS CHECK GOOD.SDR DALA2020012420566Battery · no testDURING INSPECTION FOUND SEAT EMERGENCY LIGHT INOP BETWEEN ROW 19-23. REMOVED AND REPLACED BATTERY FOR ROW 19-23. OPS CK GOOD.SDR DALA2020011000186Battery Pack · discharged(LOG 6719867) DURING INSPECTION FOUND NUMEROUS EMERGENCY LIGHTS INOPERATIVE THROUGHOUT CABIN. REPLACED BATTERY PACK @ M1671 LOCATION, LIGHTS OPS NML PER B 737 AMM 33-51.SDR DALA2019110406447Battery · not reported(LOG 6398356) REPLACED BATTERY AT BATTERY CHARGER M1674 PER B737 AMM 35-51. OPS CKS GOOD.SDR DALA2019071904316Lens · missing(LOG 5953102) DURING INSPECTION FOUND EXIT SIGN (LENS) MISSING AT 18A. INSTALLED NEW EXIT SIGN LENS PER AMM 33-51.SDR DALA2019062003692Sign · damaged(LOG 5439370) DURING INSPECTION FOUND AFT GALLEY EMERGENCY EXIT LIGHT SIGN IS DAMAGED. R/R EXIT LIGHT ASSEMBLY IAW B737-800 AMM 33-51. OPS NML.SDR DALA2019022601218Connector · not seated(LOG 5527914) DURING TEST FOUND EMERGENCY EXIT LIGHTS INOP ROWS 18-23. RESEATED CONNECTOR ON M1695 BATTERY PACK OPERATION OK B737 AMM 33-51.SDR DALA2019020600857Battery · dischargedDURING INSPECTION FOUND FLIGHT ATT FLASHLIGHT INOP. AT AFT LEFT OUTBOARD POSITION. R&R FLASHLIGHT BATTERY IAW AMM 25-64-00-900-806. OPS CHECK GOOD.SDR DALA2018122007310Battery Pack · failed(LOG 5235926) DURING INSPECTION FOUND LEFT WING AFT EXTERIOR EMERGENCY LIGHT AND ROW 22 OVERHEAD EXIT SIGN INOPERATIVE. FOUND BATTERY PACK M1670 BAD. R+R BATTERY PACK IAW B737 MM 33-5. LIGHT CKS OK.SDR DALA2018071204464Bulkhead · canningDURING INSPECTION FOUND OIL CAN CONDITION ON AFT PRESSURE BULKHEAD AT 9, 11, 12 AND 1 O’CLOCK POSITION AT AFT ACC COMPARTMENT. MAINTENANCE REPAIRED PER ETI-37-18-422 REV 2 AND ER/A 569931-14 REV ORIGINAL.SDR DALA2018071204463Skin · corrodedDURING INSPECTION FOUND CORROSION ON FUSELAGE SKIN AREA UNDER DORSAL FIN AND VERTICAL STABILIZER FROM STA 1016 TO STA 1156. AREA WAS REPAIRED PER ETI-37-18-427 REV 2 AND ER/A 569932-14 REV ORIG.SDR DALA2018072504689Angle · damagedDURING INSPECTION FOUND ANGLE LT STA 1075-1099 IS OUT LIMITS WITH MINIMUM REMAINING 0.034. PER B737-800 SRM ALLOWABLE DAMAGE 1 53-80-13. AREA OUT LIMITS WAS REPAIRED PER SRM 53-80-71 REPAIR 6.SDR DALA2018070504384Rib · crackedDURING INSPECTION FOUND CRACK ON RIB BTW FRONT SPAR AND REAR SPAR LT HORIZONTAL STABILIZER LE STA 95.96. AREA WAS REPAIRED PER SRM 55-10-09 REPAIR 4 FIGURE 202 AND ER/A 569674-14 REV ORIGINAL.SDR DALA2018070404380Bulkhead · crackedDURING INSPECTION FOUND CRACK AT LT MLG WHEEL WELL FWD BULKHEAD LOWER AREA. BULKHEAD LOWER AREA WAS REPAIRED PER SRM 51-40-05 PAR 7D AND 57-10-10 REPAIR 2.SDR DALA2018070304375Access Panel · damagedDURING INSPECTION FOUND EXPOSED MATERIAL ON ACCESS PANELS NBR 431ER AND 431EL OF ENGINE NR 1. ACCESS PANELS 431ER AND 431EL WERE REPAIRED PER SRM 51-70-05 REPAIR 10 AND SRM 51-70-05 REPAIR GENERAL PAR 4.SDR DALA2018070304374Access Panel · damagedDURING INSPECTION FOUND HOLGED HOLE ON ACCESS PANEL 193AL. ACCESS PANEL 193AL WAS REPAIRED PER SRM 53-40-70 REPAIR 1 PAR 4B (2). TABLE 202, SRM 51-70-05 REPAIR 8 PAR 4 F G AND SRM 51-70-05 REPAIR GENERAL PAR 4.SDR DALA2018070304373Access Panel · damagedDURING INSPECTION FOUND EXPOSED MATERIAL ON ACCESS PANEL NR 441EL OF ENGINE 2. ACCESS PANEL 441EL WAS REPAIRED PER SRM 51-70-05 REPAIR 10 AND SRM 51-70-05 REPAIR GENERAL.SDR DALA2018070304372Access Panel · wornDURING INSPECTION FOUND WEAR IN COMPOSITE MATERIAL OF ACCESS PANEL 193D. ACCESS PANEL WAS REPAIRED PER SRM 51-70-05-2R-6 PAR 4 STEP E F AND G AND SRM 51-70-05-2R-0.SDR DALA2018070504386Bulkhead · crackedDURING INSPECTION FOUND CRACK AT LT MLG WHEEL WELL FWD BULKHEAD LOWER AREA. BULKHEAD LOWER AREA WAS REPAIRED PER SRM 51-40-05 PAR 7D AND 57-10-10 REPAIR 2.SDR DALA2018070204319Skin · wornDURING INSPECTION FOUND WEAR ON SLAT 3 LOWER SKIN, WEDGE AREA. MAINTENANCE REPAIRED PER SRM 57-42-01 REP 6.SDR DALA2018063004316Rib · crackedDURING INSPECTION FOUND CRACK ON RIB BTW FRONT SPAR AND REAR SPAR RT HORIZONTAL STABILIZER LE STA 95.96. SPAR RT HORIZONTAL STABILIZER LE STA 95.96 (EHV) WAS REPAIRED PER SRM 55-10-09 REPAIR 4.SDR DALA2018063004315Plate · crackedDURING INSPECTION FOUND CRACK ON LT SIDE PLATE BTW STA 500B TO STATION 500C FWD CARGO COMPARTMENT. MAINTENANCE REPAIRED SIDE PLATE PER SRM 53-00-53 REPAIR 5.SDR DALA2018070204314Floor Support · corrodedDURING INSPECTION FOUND CORROSION ON FLOOR STRUCTURE BTWN STA 951-968 AND RBL 52 AT W2 AREA. FLOOR SUPPORT BTW STA 951-968 & RBL 52 WAS REPLACED PER SRM 51-40-02.SDR DALA2018062904281Skin · wornDURING INSPECTION, FOUND WEAR ON THE NR 2 SLAT LOWER SKIN WEDGE AREA. THE DAMAGE WAS REPAIRED IAW SRM 57-42-01, REPAIR 6.SDR DALA2018062904280Skin · wornDURING INSPECTION, FOUND WEAR ON THE NR 3 SLAT LOWER SKIN WEDGE AREA. MAINTENANCE REPAIRED THE DAMAGE IAW SRM 57-42-01, REPAIR 6.SDR DALA2018062974275Bulkhead Web · canningDURING INSPECTION, FOUND AN OIL CANNING CONDITION ON THE AFT PRESSURE BULKHEAD, AT THE 9 HRS POSITION. MAINTENANCE REPAIRED THE BULKHEAD IAW SRM 53-80-08, REP 1.SDR DALA2018062504179Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION ON THE FLOORBEAM ANGLE, BS 887 BETWEEN STRINGERS 25R AND 27L. MAINTENANCE REPLACED THE FLOORBEAM ANGLE IAW SRM 51-40-02, PAR 4.SDR DALA2018062504178Channel · corrodedDURING INSPECTION, FOUND CORROSION ON THE RT ZEE CHANNEL SIDEPLATE BETWEEN BS 727 - 947.5, RBL 21. MAINTENANCE REPLACED THE CHANNEL IAW SRM 51-40-02.SDR DALA2018062214133Floor Support · corrodedDURING INSPECTION, FOUND A CRACK ON THE FLOOR SUPPORT BETWEEN BS 312 - 328, LBL 44. REPLACED IAW SRM 51-40-02.SDR DALA2018062214132Floor Support · corroded)DURING INSPECTION, FOUND A CRACK ON THE FLOOR SUPPORT BETWEEN BS 328 - 344, LBL 44. REPLACED IAW SRM 51-40-02.SDR DALA2018062214131Floor Support · corrodedDURING INSPECTION, FOUND A CRACK ON THE FLOOR SUPPORT BETWEEN BS 328 - 312, RBL 31. THE FLOOR SUPPORT WAS REPLACED IAW SRM 51-40-02.SDR DALA2018062004090Bulkhead · canningDURING INSPECTION FOUND OIL CANNING AT LT MLG WHEEL WELL FWD BULKHEAD LOWER AREA. WHEEL WELL FWD BULKHEAD LOWER AREA WAS REPAIRED SRM 51-40-05 PAR 7D AND 57-10-10 REPAIR 2.SDR DALA2018062004092Bulkhead · canningDURING INSPECTION FOUND OIL CANNING AT RT MLG WHEEL WELL FWD BULKHEAD LOWER AREA. RT MLG WHEEL WELL FWD BULKHEAD LOWER AREA WAS REPAIRED PER SRM 51-40-05 PAR 7D AND 57-10-10 REPAIR 2.SDR DALA2018061904089Support · corrodedDURING INSPECTION FOUND CORROSION ON FLOOR STRUCTURE AREA STA 344. LEVEL CORROSION 2 IN REF NRC 00488 SUPPORT WAS REPLACED PER SRM 51-40-02.SDR DALA2018070604410Structure · corrodedDURING INSPECTION FOUND CORROSION ON FLOOR STRUCTURE ON STA 986 BTW RBL 52 AND RBL 28 AT W2 AREA. AREA WAS REPAIRED PER ERA 569903-14 REV ORIG AND ETI -37-18-423 REV 2.SDR DALA2016022901564Pneumatic System · malfunctionedCREW DECLARED AN EMERGENCY AFTER A MOMENTARY, CABIN ALTITUDE, WARNING HORN SOUNDED ON DESCENT. MAINTENANCE FOUND THE SUPPLY PRESSURE SENSE LINE BETWEEN THE PCCV AND BAR BROKEN AND REPLACED IT. PERFORMED PNEUMATIC HEALTH CHECK IAW W/C 3610-7956 AND THE OPS CHECSDR DALA2015122407713Skin · damagedDURING SCHEDULED MAINTENANCE VISIT, TWO EXISTING LIGHTNING STRIKE MONITORS WERE FOUND IN THE FOOTPRINT OF THE SAT TV ANTENNA MOD BEING INSTALLED AT CURRENT CHECK. MAINTENANCE REPAIRED IAW ERA 540735-14AD.SDR DALA2015122007701Attach Angle · corrodedDURING INSPECTION FOUND AFT PIT LT SIDEWALL PANEL LOWER FLOOR Z-ANGLE ATTACH CORRODED FROM BS 767 TO 727H. MAINTENANCE R & R AFT PIT LTSIDEWALL PANEL LOWER FLOOR Z-ANGLE FROM BS 767 TO 727H, DUE TO BEING OUT OF LIMITS.SDR DALA2015122007700Support · corrodedDURING INSPECTION, FOUND AFT PIT RT FLOOR TO SIDEWALL ATTACHING FLOOR SHIELD HAS SURFACE CORROSION AT FASTENER LOCATIONS BS 787-727J. MAINTENANCE R & R SHIELD ASSY IAW DWG 146A8127 ID 001, REV C, 7 DWG 146A0081 ID 0001, REV B.SDR DALA2015121007556Seat Track · wornDURING INSPECTION, FOUND PASSENGER CABIN SEAT TRACK BS 520, RBL 24 IS WORN. MAINTENANCE REMOVED AND INSTALLED NEW PASSENGER CABIN SEAT TRACK IAW SRM 53-00-52, REPAIR 4.SDR DALA2015121007555Seat Track · wornDURING INSPECTION, FOUND PASSENGER CABIN SEAT TRACK BS 520, RBL 45 IS WORN. MAINTENANCE REMOVED AND INSTALLED NEW PASSENGER CABIN SEAT TRACK IAW SRM 53-00-52, REPAIR 4.SDR DALA2015121007554Seat Track · wornDURING INSPECTION FOUND PASSENGER CABIN SEAT TRACK BS 520, LBL 45 IS WORN. MAINTENANCE REMOVED AND INSTALLED NEW PASSENGER CABIN SEAT TRACK IAW SRM 53-00-52, REPAIR 4.SDR DALA2015121007553Seat Track · wornDURING INSPECTION, FOUND PASSENGER CABIN SEAT TRACK BS 520, LBL 24 IS WORN. MAINTENANCE REMOVED AND INSTALLED NEW PASSENGER CABIN SEAT TRACK IAW SRM 53-00-52, REPAIR 4.SDR DALA2015092505832Door · damagedDURING INSPECTION, FOUND DAMAGE TO MAIN ELECTRONICS AND EQUIPMENT DOOR BEYOND SRM ALLOWABLE LIMITS. MAINTENANCE REPLACED ELECTRONICS AND EQUIPMENT DOOR IAW AMM. LEAK CHECK OK.SDR DALA2014082204681Light · missingDURING INSPECTION, FOUND EMERGENCY LIGHT ASSY ON SEAT 16B MISSING. MAINTENANCE INSTALLED LIGHT. OPS TEST OK.