N402UA
Service difficulty reports · 143
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N402UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N402UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010041201220Life Vest · out of positionLIFE VESTS ARE NOT IN POUCHES IN CABIN. SECURED 10EA LIFE VESTS IN VARIOUS ROWS, MOSTLY 'C' SEATS.SDR UALA2009121403846Control Cable · faultyCREW REPORTS OF DOOR 1R ARMING LEVER FROZEN. REMOVED DOOR 1R LINING. INSPECTED FLEX CONTROL CABLE FOR SLIDE DISARM LEVER. REMOVED CABLE. INSTALL DOOR 1R FLEXIBLE CONTROL ASSY (ARM CABLE). REPLACED FLEXIBLE CONTROL CABLE.SDR UALA2009121403840Cable · faultyCREW REPORTS OF DOOR 1R ARMING LEVER FROZEN. REMOVED DOOR 1R LINING. INSPECTED FLEX CONTROL CABLE FOR SLIDE DISARM LEVER. REMOVED CABLE. DOOR LINERS IN GALLEY AND COCKPIT. CABLE DIMENSIONS: X1=1.859, X2=.687, X3=.828, X4=2.468. BAD CABLE IS ATTACHED TO DOOSDR UALA2009082102582Ballast · faultyFWD GALLEY LIGHT WILL NOT GO BRIGHT. RELAMPED, NO HELP. REPLACED BALLAST 9019WL1. LIGHT OP CHECKS OKAY.SDR UALA2009031000688Slide · faultyDOOR 1L SLIDE PRESSURE GAUGE. REMOVED AND REPLACED SLIDE-RAFT ASSY.SDR UALA2009030200688Slide · faultyDOOR 1L SLIDE PRESSURE GAUGE. REMOVED AND REPLACED SLIDE-RAFT ASSY.SDR 2008UALA05464Unknown · unknownNR 2 ENGINE EPR FAULT. RTFL.SDR 2008UALA04008Slide · shortedFAILED EMERGENCY LIGHT TEST. *S/D* INTERNAL SHORT/RESISTANCE IN SLIDE 1L. REPLACED SLIDE 1L. OPS CHECKED GOOD.SDR 2008UALA03460Sign · inadequateEMERGENCY LIGHT WILL NOT PASS TEST AT 1L. FOUND EXIT SIGN AT 1R OVER DOOR VERY DIM. REPLACED SIGN ASSY, OPS CHECKED NORMAL.SDR 2008UALA03421Light · failedEMERGENCY LIGHT TEST ON CIDS PANEL FAILED IT'S TEST. FAULTED THE UNIT.SDR 2008UALA00818Pump · leakingFLIGHT DIVERTED DUE TO LOSS OF GREEN HYDRAULIC SYSTEM. HYDRAULIC LEAK AT PTU. REPLACED PTU AND ALSO FOUND NR 1 EDP LEAKING, REPLACED AS WELL. SERVICED HYDRO FLUID AND PUT GEAR SYSTEM BACK TO NORMAL CONFIG. ALL SYSTEM TEST GOOD.SDR 2008UALA00350Strap · out of positionPART OF SLIDE PACK IS HANGING FROM DOOR 1R WHILE THE DOOR IS CLOSED. D RING STRAP WAS OUTSIDE OF PACK ASSY, SECURED THE D RING STRAP, INSP SLIDE. ALL OK.SDR 2007UALA05220Slide · faultyPER EMER LIGHT CK ON 3SVC, LEFT AFT DOOR SLIDE FAILED TEST. ELECTRICAL FAULT IN SLIDE 2L. REPLACED SLIDE 2L- OPS CHECKED NORMAL.SDR 2007UALA03578Wire · crushedSEATS 1, 2, 3, 6, 19 FLOOR PROXIMITY LIGHTS INOP. FOUND CRUSHED WIRING AND WEAK BATTERY/EPSU. REPLACED BATTERY AND EPSU AND REPAIRED AND RELAMPED UNITS.SDR 2007UALA03509Battery · dischargedEMERGENCY LIGHT LEFT FWD UNIT FAULT. REPLACED FWD LEFT EPSU BATTERY. OPS CHECK GOOD. NO FAULTS RETURNED.SDR 2007UALA02990Pump · malfunctionedCREW REPORTS AT 370 HAD YEL HYD ENG PUMP LO PRESS AND PUMP FAULT LIGHT WITH THE PRESSURE DROPPING TO 2100 PSI. PTU THEN CAME ON LINE. ENG PUMP TURNED OFF. 09-07-07 REPLACED EDP, FILTERS.SDR 2007UALA01890Girt Bar · faultyFOUND 2R DOOR DIFFICULT TO ARM.SDR 2007UALA01160Strap · misroutedMED 2R SLIDE ARMING LEVER CAME OUT OF THE ARM POSITION IN FLIGHT (ALSO ECAM SHOWED NOT ARMED). PER SAMC CYCLED ARMING LEVER AND HANDLE WILL NOT ARM AND SLIGHT NOISE IN DOOR AREA. [06-12-07] FOUND GIRT BAR YELLOW STRAP WEDGED IN GIRT BAR MOUNT SLOT. RSDR 2007UALA00832Cover · out of positionTHE 2L SLIDE COVER FELL OFF. [SUP 05-18-07] SECURED SLIDE COVER.SDR 2007UALA00352Proximity Switch · faultyDOOR 1 ARMS, BUT WILL NOT INDICATE ARMED ON COCKPIT. [SUP 05-08-07] FAULT TRACED TO OUT OF ADJUSTMENT PROXIMITY SWITCH. MORE SPECIFICALLY, A LOOSE LOCK WASHER ON THE PROXIMITY TARGET. REPLACED LOCK WASHER AND READJUSTED PROXIMITY SWITCH TO PROPER CLEARANCE.SDR 2007UALA00319Wire · faultyFOUND EMERGENCY EXIT PATH LIGHT IS INOP AT SEAT 18. REPAIRED WIRING UNDER SEAT 18ABC, AT PATH LIGHT CONNECTOR. OPS CHECKED OK.SDR 2007UALA00318Wire · shortedFOUND EMERGENCY EXIT LIGHTS INOP AT ROWS 1, 2, 3, 6. REPAIR SHORTED WIRES UNDER SEAT 6ABC. ALL EMERGENCY LIGHTS TESTED OK.SDR 2006UALA01706Radar · failedDIVERTED DUE TO LOSS OF RADAR.SDR 2006UALA01355Structure · vibrationFLIGHT REPORTED A VIBRATION ON CLIMBOUT IN THE COCKPIT & A STRONGER VIBRATION IN THE TAIL & AFT GALLEY. ACCOMPLISHED AMM5-50-00. VIBRATION DECICION TREE SUGGESTS TYPE 1 ELEVATOR AS MOST PROBABLE CAUSE. MAINTENACE TIP 53-005 ALSO ACCOMPLISHED. AM27-34-00-20SDR 2006UALA01276Light · inoperativeEMERGENCY PATH LIGHTING IS INOP AT OVER WING EXT AND ALSO THE EXIT SIGNS ARE INOPERATIVE. REPLACED BATTERY CHARGER GROUND CHECKS NORMALSDR 2006UALA01086Battery · failedEMERGENCY LIGHT TEST FAILS. REPLACED BATTERY AT DOOR 1 LEFT. TESTS OK.SDR 2006UALA00802Cylinder · low pressureFOUND DOOR 2L SLIDE PACK INFLATION CYLINDER PRESSURE LOW. REPLACED DOOR 2L SLIDE/RAFT. SLIDE/RAFT REMOVED DID NOT FULLY DEPLOY DUE TO A LEAK FROM ONE OF THE SEAMS. FIRST REPLACEMENT SLIDE/RAFT REJECTED DUE TO LOW PRESSURE. SECOND REPLACEMENT INSTALLED.SDR 2005UALA00684Battery Pack · failedEMERGENCY LIGHTS BITE TEST FAILS "BATT FWD L". REPLACED FWD LT EMERGENCY BATTERY PACK.SDR 2005UALA00667Epsu · malfunctionedEMERGENCY EXIT PATHWAY LIGHTS WILL NOT EXTINGUISH. REPLACED EMERGENCY POWER SUPPLIES 112WL2, 111WL2 AND 110WL2. OPS CHECK GOOD.SDR 2005UALA00643Light · will not testWHILE PERFORMING EMERGENCY LIGHT TEST FAILED WITH MESSAGE EXT LOADS FWD LEFT. REPLACED SLIDE.SDR 2005UALA00382Transducer · failedCREW RECEIVED LOW PRESSURE GREEN HYDRAULIC PUMP INDICATION. GREEN SYSTEM PRESSURE TRANSDUCER FAILED. REPLACED THE TRANSDUCER.SDR 2004UALA00503Yaw Damper · leakingFLT LANDED UNDER AMBER ALERT DUE TO LOSS OF GREEN HYDRAULIC SYSTEM. YAW DAMPER NR 1 WAS FOUND LEAKING. UNIT WAS REPLACED. OPERATIONS CHECK NORMAL.SDR 2003UALA00808Outflow Valve · malfunctionedRETURN TO FIELD DUE TO INABILITY TO PRESSURIZE AIRCRAFT. REPLACED FAULTY SKIN AIR OUTFLOW VALVE.SDR 2003UALA00741Structure · contaminatedINDICATIONS OF WATER INGRESS WERE FOUND IN 4 AREAS. ALL AREAS WERE APPROX 2.5 X 2 INCHES AND WERE APPROX 3 INCHES FROM THE TRAILING EDGE. THE FIRST AREA WAS ON THE LT UPPER SURFACE 102 INCHES FROM THE INBOARD EDGE. THE OTHER 3 AREAS WERE ON THE LT LOWER SURSDR 2003UALA00740Skin · damagedWATER INGRESS WAS FOUND AT 2 LOCATIONS ON THE RT ELEVATOR. DAMAGE ON UPPER SKIN IS 2.8 BY 2 INCHES AND IS 127 INCHES FROM IB EDGE AND 20 FROM TRAILING EDGE. MAJOR REPAIR ACCOMPLISHED. REPAIR DAMAGED AREAS PER SRM 55-21-11 TO ELIMINATE WATER INGRESSION.SDR 2002UALA01466Brake Assy · malfunctionedRETURNED TO FIELD UNDER AMBER ALERT DUE TO LEFT BRAKE WOULD NOT COOL. REPLACED NR 1 BRAKE ASSEMBLY. NO PREVIOUS HISTORY OF HIGH TEMPS. NO FURTHER DEFECTS ON SUBSEQUENT FLIGHTS.SDR 2000UALA00643Light · will not testEMERGENCY LIGHTS FAIL TEST FROM THE PROGRAMMING AND TEST PANEL. REPLACED RIGHT HAND OVERWING EMERGENCY LIGHT POWER SUPPLY. OPERATIONAL TEST NORMAL.SDR 2000UALA00440Light · inoperativeEMERGENCY ESCAPE LIGHTS AT ROWS 15, 16, 17, 21, 22, 23 NOT OPERATING DURING EMERGENCY LIGHT TEST.SDR 2000UALA00303Fan · failedSTRONG ODOR THROUGHOUT CABIN IN DESCENT THRU 4000 FT. *S/D* FOUND AVIONICS BLOWER 20HQ TO BE MAKING EXCESSIVE NOISE. REMOVED AND REPLACED FAN. OPERATIONAL CHECK GOOD.SDR 98UAL900623Lgciu · damagedECAM FOR UNSAFE LANDING GEAR DISPLAYED. CAPT RECYCLED GEAR AND IT CAME DOWN AND LOCKED NORMALLY. *S/D* CAPT RECYCLED GEAR AND IT CAME DOWN AND LOCKED NORMALLY. REPLACED NR 1 LGCIU DUE TO BROKEN PIN AT J-1. INSPECTED PROX SENSORS 13GA AND 19GA. JACKED AIRSDR 98ZZZX4719Seat · crackedDURING THE FIRST HEAVY MAINTENANCE VISIT, VIRTUALLY 100 PERCENT OF THE SEAT PANS ON THE RECARO MODEL 3410, 720 SERIES COACH SEATS WERE FOUND CRACKED AT THE FORWARD EDGE OF THE SEAT PAN. THE CRACKS ARE AT THE MOUNTING HOLES WHERE THE SEAT PAN MOUNTS TO THE SEASDR 96UAL900471Light · failed testEMERGENCY ESCAPE LIGHTS FAIL OPERATIONAL TEST.SDR 95UAL900024Eel Battery Pack · dischargedEEL LIGHTS INOP AT DOOR 1L. REPLACED BATTERY PACK.