N402UP
Service difficulty reports · 329
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N402UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N402UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2016092108516Floor Panel · damagedINSPECTION TYPE: SEG2, MAIN DECK FLOOR PANEL 231XFF BS 480 DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015091193419Window · failedR1 WINDOW SHATTERED FL 320. R & R R1 WINDOW ASSY IAW AMM 56-11-01-424-015.SDR IPXA2014011001275Yaw Damper · faultedACFT SUDDENLY STARTED TO YAW SHARPLY, BOTH LT & RT BALL DEFLECTED FULL SCALE IN SLIP INDICATOR. DESCENT TO FL300 & SPEED REDUCTION TO .78 MACH, TURNING OFF AUTOPILOT HELPED. YAWING STOPPED. TROUBLESHOT IAW FIM 22-21-00. FOUND LT YAW DAMPER SYSTEM FAULTED. SDR IPXA13578134Skin · dentedRT FUSELAGE SKIN DENTED BS 1681 S7R. REPAIRED IAW EO B757-5330-50447-B.SDR IPXA13577137Wedge · gougedINSPECTION TYPE:C-16, RT WING OTBD AFT FLAP, LOWER SURFACE GOUGED JUST OTBD OF OTBD FAIRING. REPAIRED AFT FLAP IAW SRM 51-70-04.SDR IPXA13577048Wedge · chafedINSPECTION TYPE:C16, RT WING NR 8 SLAT T/E WEDGE CHAFED. REPAIRED THE SLAT IAW SRM 51-70-10, REPAIR NR 4, FIG NR 202, SHEET NR 8.SDR IPXA12576070Skin · dentedRT WING NR8 SLAT T/E WEDGE UPPER SKIN DENTED. REPAIRED REF EO B757-5750-47012-B.SDR IPXA2574566Lamp · inoperativeEMERGENCY LIGHT ASSY HAS FOUR LAMPS INOPERATIVE. INSTALLED FOUR LAMPS IN THE EMERGENCY LIGHT ASSY IAW AMM 33-51-01.SDR IPXA12574512Circuit Card · inoperativeLANDING GEAR MONITOR STATUS MESSAGE ON CLIMBOUT. TROUBLESHOT SYS IAW FIM 32-61-00. R & R PROXIMITY CIRCUIT CARD 14 IAW MM 32-09-06-404-008. OPS CHECKED GOOD IAW 32-09-06-704-014.SDR IPXA2573926Skin · dentedLEFT WING NR 4 SLAT UPPER SURFACE HAS A DENT WITH DELAMINATION, 62" FROM INBD EDGE AND 5. 3" FROM T/E. REPAIRED REF EO B757-5750-47000-B.SDR IPXA2573925Skin · dentedLEFT WING NR 4 L/E SLAT HAS THREE DENTS, 36.5" FROM INBD EDGE AND 1.2" FROM T/E UPPER SURFACE. REPAIRED REF EO B757-5750-4700-B.SDR IPXA2573924Skin · dentedLEFT WING NR 4 L/E SLAT HAS DENT WITH DELAMINATION, 15.5 FROM INBD EDGE AND 3.375 FROM T/E UPPER SURFACE. REPAIRED REF EO B757-5750-47000-B.SDR IPXA2573915Skin · dentedLEFT WING NR 4 SLAT HAS DENT WITH DELAMINATION 15.5" FROM INBD EDGE AND 3.375" FROM T/E UPPER SUFACE. REPAIR REF EO B757-5750-47000B.SDR IPXA2573906Skin · dentedNR 5 SLAT T/E WEDGE DENTED UPPER SKIN .750 DIA WITH CORE DAMAGE 7" FROM INBD EDGE AND 5.5" FROM AFT EDGE. REPAIRED IAW SRM 51-70-10-2R, REPAIR 2.SDR IPXA12573832Skin · dentedNR 1 SLAT T/E WEDGE UPPER SKIN HAS SIX DENTS IN CLOSE PROXIMITY TO EACH OTHER DEMENSION FOR DENTS ARE ON EO B757-5750-46984, FIG 1. REPAIRED REF EO757-5750-46984-B ALSO USE NR 511105 & 511102.SDR IPXA12573831Wedge · dentedDENT ON T/E WEDGE OF NR 7 SLAT LOCATED 22.5 OTBD OF INBD EDGE AND 6.0" FWD OF AFT EDGE CUT OUT DIA 1.25. REPAIRED REF EO B757-5750-47413A.SDR IPXA12573830Wedge · dentedDENT ON TE WEDGE OF NR 7 SLAT LOCATED 46.25 INBD OF INBD EDGE AND 6.0 FWD OF T/E CUT OUT DIA 1.40. REF REPAIR EO B757-5750-47412-A.SDR IPXA12573829Skin · dentedFOUR DENTS ON NR 7 SLAT BETWEEN 52"-58" INBD T/E WEDGE REF EO B757-5750-470 11-A. REPAIRED REF EOB757-5750-47011-B.SDR IPXA12573834Wedge · dentedNR 3 SLAT T/E WEDGE HAS THREE DENTS IN CLOSE PROXIMITY TO EACH OTHER. REPAIRED IAW EO B757-5750-46999-B.SDR IPXA11570575Gearbox · failedRT GENERATOR OFF LIGHT ON TAKEOFF. LT AND RT UTILITY BUSSES TRIPPED, APU SHUTDOWN WITH APU FAULT. EMERGENCY DECLARED. TROUBLESHOT APU IAW FIM 49-11-00-815-855-001, FOUND OIL COOLING FAN DRIVE GEARS AND APU GEARBOX DRIVE GEARS DAMAGED IAW STEP 5 AND 13 OF SDR IPXA11566229Frame · damagedINSPECTION TYPE:SP, REPLACED UPPER SKIN ON MCD. FOUND DOUBLE HOLE COMMON TO BS 520, FRAME STR 10L. REPAIRED IAW ATS ER NR 11-02359.SDR IPXA11566224Frame · damagedINSPECTION TYPE:SP, REPLACED UPPER SKIN ON MCD, FOUND DOUBLE HOLE COMMON TO BS 520, STR 10L LOWER SKIN PANEL LAP AREA'S. REPAIR IAW ATS ER 11-02359.SDR IPXA1566301Frame · damagedINSPECTION TYPE:SP, BS 580 FRAME HAS DOUBLE DRILLED HOLE AT APPROX 2 INCH DOWN FROM TOP OF DOOR. REPAIRED IAW ER 11-02357, DATED 30-APR-2011 AND EO B757-5230-42377-A, DATED 02-MAY-2011.SDR IPXA1566300Frame · damagedINSPECTION TYPE:SP, BS 540 FRAME HAS DOUBLE DRILLED HOLE AT APPROX 2 INCH DOWN FROM TOP OF DOOR. REPAIRED IAW ER 11-02357, DATED 30-APR-2011, AND EO B757-5230-42377-A, DATED 02-MAY-2011.SDR IPXA1566299Frame · damagedINSPECTION TYPE:SP, BS 590 FRAME HAS DOUBLE DRILLED HOLE AT APPROX 2 INCH DOWN FROM TOP OF DOOR. REPAIRED IAW ER 11-02357, DATED 30-APR-2011 AND EO B757-5230-42377-A, DATED 02-MAY-2011.SDR IPXA1566298Frame · damagedINSPECTION TYPE:SP, BS 520 FRAME HAS DOUBLE DRILLED HOLE AT APPROX 2 INCH DOWN FROM TOP OF DOOR. REPAIRED IAW ER 11-02357, DATED 30-APR-2011 AND EO B757-5230-42377-A, DATED 02-MAY-2011.SDR IPXA1566297Frame · damagedINSPECTION TYPE:SP, BS 560 FRAME HAS DOUBLE DRILLED HOLE AT APPROX 2 IN DOWN FROM TOP OF DOOR. REPAIRED IAW ATS ER 11-02357, DATED 30-APR-2011 AND EO B757-5230-42377-A, DATED 02-MAY-2011.SDR IPXA11566235Frame · damagedINSPECTION TYPE:SP, MCD, BS 600 OUTER FRAME CHORD 22" DOWN FROM UPPER EDGE OFFSET PILOT HOLES IN 4 EA FASTENERS HOLES MARKED. REPAIR IAW ATS ER 11-02350.SDR IPXA11566228Skin · damagedINSPECTION TYPE:SP, MCD BS 530 UPPER MOST HOLE ON INNER SKIN IS DAMAGED. REPAIRED IAW ATS ER 11-02194.SDR IPXA11566090Attach Angle · damagedINSPECTION TYPE:SP ATTACH ANGLE COMMON TO THE BS 500 FRAME AND UPPER BEAM REQUIRES REPLACEMENT (HOLE IS OVERSIZED AND COMMON TO THE HINGE ALSO) REMOVED, FABRICATED AND INSTALLED NEW ATTACH ANGLE IAW SRM 51-40-02-0G, SRM 51-40-05-0G, BOEING DRAWING 65-2533SDR IPXA11566089Skin · damagedINSPECTION TYPE:SP, MCB BS 530 UPPER MOST HOLE ON INNER SKIN STRAP IS DAMAGED REMOVED, FABRICATED NEW INNER SKIN STRAP IAW SRM 51-40-02, SRM 51-40-05-0G, SRM 51-20-01-0G DWG 65-25347-8.SDR IPXA11566227Skin · damagedINSPECTION TYPE:SP, REPLACE UPPER SKIN SECTION ON MCD. REPAIRED IAW ATS ER NR 11-02156.SDR IPXA11566182Casting · damagedINSPECTION TYPE:SP, REPLACED AFT LIFT ACTUATOR CASTING. REPLACED AFT LIFT ACTUATOR CASTING (FITTING) ON MCD IAW AMM 52- 32-04-4, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-20-01-0G, DWG 65-25337 REV C, DWG 65-25329 REV F, DWG 65-25330 REV J, DWG 65-25334 SH 3, SDR IPXA11566181Casting · damagedINSPECTION TYPE:SP, REPLACE FWD LIFT ACTUATOR CASTING. REPLACED FWD LIFT ACTUATOR CASTING (FITTING) ON IAW AMM 52- 32-04-4, SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-20-01-0G, DWG 65-25337, REV C, DWG PL 65-25327, DWG PL 65-25328, DWG PL 65-25334, DWG PL 65-25SDR IPXA1565753Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL BS 900-1020, RBL 45-60 HAS EDGE DAMAGE AND MISSING INSERTS. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G, AND SRM 53-00-50-1A1.SDR IPXA1565752Floor Panel · damagedINSPECTION TYPE:C3, FLOOR PANEL BS 900-1020, RBL 25-45 HAS DAMAGED EDGES AND MISSING INSERTS. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G, AND SRM 53-00-50-1A1.SDR IPXA1565815Floor Panel · misalignedINSPECTION TYPE:C3, DUE TO FLOORBEAM REPAIR AT BS 1200, FLOOR PANEL FASTENER HOLES IN FLOOR PANEL BS 1100 TO 1200 BL0 TO LBL 25 REQUIRES TO BE RELOCATED TO MATCH FLOORBEAM ATTACH HOLES IN SPLICE AREA AT BS 1200. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-969SDR IPXA1565757Floor Panel · misalignedINSPECTION TYPE:C3, DUE TO FLOORBEAM REPAIR AT BS 1200, FLOORPANEL FASTENER HOLES IN FLOORPANEL BS 1100 TO 1200 BL0 TO LBL 25 REQUIRES TO BE RELOCATED TO MATCH FLOORBEAM ATTACH HOLES IN SPLICE AREA AT BS 1200. FABRICATED NEW FLOOR PANEL IAW EO B757-5100-33281SDR IPXA11565636Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT BS 297-333 BL 0 - RBL 60 HAS DAMAGE TO INSERTS AND EDGES. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692G.SDR IPXA1565392Floorboard · damagedINSPECTION TYPE:C3, FLOORBOARD AT BS 297-333 BL 0- RBL 60 HAS DAMAGE TO INSERTS & EDGES. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565637Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS SEVERAL AREAS OF DAMAGE BS 333-440 RBL, 45-65. FABRICATED NEW MCB FLOOR PANEL IAW EO 5320-9692-G.SDR IPXA11565631Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS SEVERAL AREAS OF DAMAGE BS 333-440, LBL 1-25. FABRICATED FLOOR PANEL IAW EO B757-5320-9692G.SDR IPXA11565477Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS SEVERAL AREAS OF DAMAGE BS 333-440, LBL 25-45. FABRICATED REPLACEMENT FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565473Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS SEVERAL AREAS OF DAMAGE BS 333-440, RBL 1-25. FABRICATED REPLACEMENT FLOOR PANEL IAW EO 757-5320-9692-G.SDR IPXA1565380Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL HAS SEVERAL AREAS OF DAMAGE BS 333-440, LBL 45-65. FABRICATED NEW FLOOR PANEL IAW B757-5320-9692-G.SDR IPXA11565607Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 880-900 LBL 1-25 HAS MISSING INSERTS, EDGE DAMAGE AND A LOOSE ATTACH PLATE. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G & EO B757-5100-33281-C.SDR IPXA11565604Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 720-820 RBL 1-24 HAS A MISSING INSERT. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G & B757-5100-33281-C.SDR IPXA11565603Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 880-900, RBL 1-25 HAS MISSING INSERTS, EDGE DAMAGE AND A LOOSE ATTACH PLATE. FOUND TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G & EO B757-5100-33281-C.SDR IPXA11565517Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 720-820, LBL 26-44 HAS EDGE DAMAGE. REPLACED FLOOR PANEL IAW SRM 53-00-50-1A1, EO B757-5320-9692-G, B757-5100-33281-C.SDR IPXA11565499Floor Panel · damagedINSPECTION TYPE:C3, MCB FLOOR PANEL BS 820-880, LBL 46-62 HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.