What was found
INSPECTION TYPE:C3, MCB FLOOR PANEL BS 880-900, RBL 1-25 HAS MISSING INSERTS, EDGE DAMAGE AND A LOOSE ATTACH PLATE. FOUND TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G & EO B757-5100-33281-C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C3, MCB FLOOR PANEL BS 880-900, RBL 1-25 HAS MISSING INSERTS, EDGE DAMAGE AND A LOOSE ATTACH PLATE. FOUND TO BE OUT OF LIMITS, FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G & EO B757-5100-33281-C.