N409UP
Service difficulty reports · 232
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N409UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N409UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2014091784327Warning Light · illuminatedCAPTAIN`S AND F/O'S PITOT AND AUX PITOT LIGHTS ON WITH PROBE HEAT MESSAGE PASSING 190 AGL R AND R TEST PANEL IAW FIM 30-31-00-990.SDR IPXA2014031982330Shim · corrodedINSPECTION C-16, LOWER FUSELAGE SKIN BULGING BS 1460. REPLACED SHIM IAW SRM 51-40-02.SDR IPXA2014031982329Shim · corrodedINSPECTION C-16, LOWER FUSELAGE SKIN BULGING BS 1460. R & R LAMINATED SHIM IAW SRM 51-40-02.SDR IPXA2014031482246Stringer · corrodedC-16 INSPECTION, LOWER FUSELAGE SKIN BULGING AT BS 1420, RBL 8 STRINGER 29R, REPAIRED IAW DWG 146N3300.SDR IPXA2014022882087Floor Panel · crackedC-16 INSPECTION, MAIN CABIN FLOOR PANEL 241XCF IS CRACKED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578815Structure · damagedNR 8 SLAT DAMAGED. REPAIR IAW EO B757-5750-51005-A.SDR IPXA3578766Wedge · dentedNR 7 SLAT T/E WEDGE DENTED. REPAIRED IAW EO B5750-51004-A.SDR IPXA3578762Wedge · damagedNR 10 SLAT T/E WEDGE UPPER SKIN DAMAGE. REPAIRED IAW EO B757-5750-51029-A.SDR IPXA3578761Skin · damagedNR 10 SLATE WEDGE UPPER SKIN DAMAGED 50 INCHES FROM INBD EDGE 4 INCHES FROM T/E. REPAIRED IAW EO B757-5750-51028-A.SDR IPXA3578760Skin · damagedRT INBD MAIN FLAP HAS ONE INCH DENT AND DELAMINATED. REPAIRED IAW EO B757-5750-510007-A.SDR IPXA3578759Skin · dentedDENT IN SKIN BS 1947.5, LBL 10. REPAIRED SKIN IAW EO B757-5330-51013-A.SDR IPXA13578121Skin · damagedLT WING OTBD AFT FLAP UPPER SURFACE DAMAGED. REPAIRED IAW EO B575-5750-50633-A.SDR IPXA13578127Wedge · dentedLEFT SLAT T/E WEDGE HAS TWO DENTS APROX 25 FROM EA OTHER 56" OTBD OF INBD D EDGE AND 3" FWD OF AFT EDGE. REPAIRED IAW SRM 57-43-02-2R.SDR IPXA13578126Wedge · dentedLT WING NR 5 SLAT T/E WEDGE 1"X.035 DEEP DENT WITH DISBONDED. REPAIR IAW SRM 57-43-02-2R.SDR IPXA3578031Skin · puncturedRT WING OTBD AFT FLAP HAS PUNCTURE IN UPPER SURFACE SKIN AT INBD END. REPAIRED REF EO B757-5750-50560-A.SDR IPXA3578030Skin · damagedRIGHT WING OTBD AFT TE WEDGE OTBD END UPPER SURFACE SKIN DAMAGED. REPAIRED REF EO B757-5750-50561-A.SDR IPXA2575073Battery · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE. R & R SERVICEABLE BATTERY ASSY ON EMERENCY EXIT SIGN IAW MM 33-51-07-902-001. OPS CHECKED GOOD.SDR IPXA2572649Floorbeam · corrodedINSPECTION TYPE: C, CREW ENTRY STRUCTURE FLOORBEAM AT BS 310.5, LBL 58 HAS SMALL SPOT OF CORROSION. CUT OUT CORRODED TEE CAP AT BS 310.5, LBL 58 AND INSTALLED UPPER T CHORD SPLICE IAW EA 120309(IR) EO: B757-5310-46350-A.SDR IPXA12572508Frame · dentedINSPECTION TYPE: C, MAIN CARGO BAY BS 1460 STR 16-17L FRAME FLANGE IS DENTED. REPAIRED IAW EA 120282.SDR IPXA12572506Web · corrodedINSPECTION TYPE: C, MAIN CARGO BAY BS 1681, LBL 40, SHEAR WEB IS CORRODED. AROUND NUTPLATE HOLE. REPAIRED IAW EA 120304.SDR IPXA2572403Floorboard · damagedINSPECTION TYPE: C-CHECK, FLOORBOARD 241XKF EDGE DAMAGE. REPLACE FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572402Floorboard · brokenINSPECTION TYPE:C-CHECK, FLOORBOARD 231XGF BROKEN. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572396Cargo Track · corrodedINSPECTION TYPE:C-CHECK, MAIN CARGO TRACK CORRODED AROUND FASTENERS BS 1057-1074, LBL 44. REMOVED CARGO TRACK FROM BS 1040-1080. FABRICATED NEW PART IAW DWG 144N8017 AND INSTALLED.SDR IPXA2572409Floorboard · damagedINSPECTION TYPE:C-CHECK, FLOORBOARD 251XBF EDGE DAMAGE. REPLACEED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572407Floorboard · damagedINSPECTION TYPE:C-CHECK, FLOORBOARD 231XJF EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572406Floorboard · delaminatedINSPECTION TYPE:C-CHECK, FLOORBOARD 231XFF DELAMINATED. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572405Floorboard · delaminatedINSPECTION TYPE:C-CHECK, FLOORBOARD 221XCF DELAMINATED. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572404Floorboard · damagedINSPECTION TYPE:C-CHECK, FLOORBOARD 231XBF EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572378Floor Panel · damagedINSPECTION TYPE:C-CK MAIN CARGO FLOOR PANEL 232XGF DAMAGED AT EDGE OF PANEL. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2572246Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 232XHF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2572245Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 241XBF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2572244Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 232XNF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9696-HSDR IPXA2572325Floorboard · damagedINSPECTION TYPE:C-CHECK, FLOORBOARD 231XCF DAMAGED. REPLACE FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572108Floorboard · damagedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 232XPF MISSING INSERTS AND DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572092Floorboard · damagedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 232 XCF MISSING INSERTS AND DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572741Fitting · corrodedINSPECTION TYPE: C, RT WING FRONT SPAR INBD SUPPORT FITTING FOR TRUNNION BEARING HAS CORROSION AROUND LOWER FUSE PIN BUSHING. REMOVED CORROSION AND INSTALLED OVERSIZED BUSHINGS. WORK DONE IAW EA 120363 AND EO B757-5740-46395-A.SDR IPXA12572740Fitting · corrodedINSPECTION TYPE: C, RT WING FRONT SPAR OTBD SUPPORT FITTING FOR TRUNNION BEARING HAS CORROSION AROUND LOWER FUSE PIN BUSHING. REMOVED CORROSION AND INSTALLED OVERSIZED BUSHINGS. WORK DONE IAW EA 120363 AND EO B757-5740-46395-A.SDR IPXA2572621Support Fitting · corrodedINSPECTION TYPE: C, LEFT WING FRONT SPAR OTBD SUPPORT FITTING FOR TRUNNION BEARING HAS CORROSION AROUND LOWER FUSE PIN BUSHING. REMOVED CORROSION BY LINE REAM BORING AND INSTALLED OVERSIZED BUSHINGS. ALL WORK DONE IAW EA 120364 AND B757-5740-46394-A.SDR IPXA2572620Support Fitting · corrodedINSPECTION TYPE: C, LEFT WING FRONT SPAR INBD SUPPORT FITTING FOR TRUNNION BEARING HAS CORROSION AROUND LOWER FUSE PIN BUSHING. REMOVED CORROSION BY LINE REAM BORING AND INSTALLED OVERSIZED BUSHINGS. ALL WORK DONE IAW EA 120364 AND EO.SDR IPXA12572089Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD NR 251XRF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572648Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 252XDF IS DELAMINATED. REPLACED FLOORBOARD NR IAW EO B757-5320-9692-H.SDR IPXA2572209Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 231XEF IS DELAMINATED. REPLACED FLOORBOARD UAW EO B757-5320-9692-H.SDR IPXA2572208Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 231XDF IS DELAMINATED. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572207Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 231XLF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-H .SDR IPXA2572206Floorboard · brokenINSPECTION TYPE: C, MAIN DECK FLOORBOARD 231XMF IS BROKEN. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572205Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 221XCF IS DELAMINATED. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572203Floorboard · delaminatedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 222XAF IS DELAMINATED. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572200Floorboard · delaminatedINSPECTION TYPE:C, MAIN DECK FLOORBOARD 231XKF IS DELAMINATED. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572199Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 211XAF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572198Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 222XBF HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.