N41135
Service difficulty reports · 91
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N41135' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N41135' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2022050201111None · corrodedSUPPORT TASK MAIN CABIN R2 DOOR LOWER SILL HAS CORRODED CHORD ST A 680 RBL 65, TRANSCRIBED FROM HAECO GSO NR 9287526 REMOVED CORROSION IAW B757-200 SRM 51-40-02 ORIGINAL MATERIAL .1 PN 143N8328U53 PO 1028565.1 IAW B757-200 SRM 51-40-05, 51-40-08 00, REMOVED .0SDR CALA2022042901098Beam · corrodedB757-53-3-0479 GALLEY 1B FLOOR STRUCTURE T-CAP STATION 365 INBOA RD HAS APPROX 2O" CORROSION, TRANSCRIBED FROM HAECO GSO NR 92868 39 REMOVED CORROSION ON T-CAP AT STA 365. ORIGINAL MAT THICKNESS IS 53-00-51-2R-10 REPAIR 10 FIG 201 DETAIL I AND II. RESTORED FINSDR CALA2022042701080Floorbeam · corrodedB757-53-3-0559 FLOOR BEAM AT STA 720RH - FROM RBL 24.75 TO RBL 5 8.22 T-CAP MULTIPLE AREAS OF CORROSION, TRANSCRIBED FROM HAECO GSO NR 9287021 REMOVED AND REPLACED FLOOR BEAM UPPER STRAP PN 95-030-3 IAW B757 -200 SRM 51-40-02 AND TRAMCO DWG 95-030 REV A. HAECSDR CALA2022041400979Structure · corrodedSUPPORT TASK MAIN CABIN R1 DOOR LOWER SILL HAS CORRODED CHROD ST A 365 RBL 65, TRANSCRIBED FROM HAECO GSO NR 9287527SDR CALA2021112202144Service Panel · missingAFT LAV SERVICE PANEL FOUND MISSING ON ARRIVAL DOOR WAS MISSING ON ARRIVAL, REMOVED HINGES AND SECURED DRAINS PLACED ON CDL. VALVES CLOSED. DISPATCH DESK: 51 NAME: TM DATE: 19-NOV-21- TOMC AND DISPATCH APPROVED, OK TO DEFER PER CDL 52EK DOOR ASSEMBLY IS P/N SDR CALA2021051200646Cover · looseDOOR-MOUNTED ESCAPE SYSTEM DOOR 2R - A EVACUATION SLIDE PROBLEM WAS ENCOUNTERED WHICH IS NOT COVERED IN THE FAULT CODE DIAGRAMS SLIDE COVER AT DOOR 2R IS LOOSE/UNATTATCHED RE-ENGAGED FORWARD BUSTLE LATCH.SDR CALA2020110401243Seal · looseWHILE CLB THRU FL265 VERY LOUD PIERCING SQUEAL OCCURRED FROM CENTER LOWER AREA OF L2/L3 WINDOWS DEBRIEFED CREW. PER CAPTAIN LOUDEST SQUEAL IS EMINATING FROM LOWER PART OF L2 /L3 WINDOW HIGH PITCHED SQUEAL. REMOVED AND REPLACED L2 WINDOW PRESSURE SEAL, PER AMSDR CALA2019042200629Girt Bar · disconnectedDOOR 2L UNABLE TO OPEN FOUND AFT END OF GIRT BAR DISCONNECTED. RECONNECTED PER AMM 25-66-01 AND DOOR OPS CHECK GOOD INSPECTED #2L MED PER B757 AMM 25-66-01, AND FOUND DOOR TO BE OPERATING NORMAL. NO DISCREPANCIES.SDR CALA2019041900591Skin · crackedB757-54-3-0052 NO.1 ENG FWD PYLON O/B PNL 433CL, AT LWR CUTOUT CRACK FOUND. REF ST SAA N/R 0059964. ACCOMPLISHED INTERIM REPAIR ON NO.1 PYLON OB SKIN AND PRODUCTION DOUBLER IAW EC/RA 5450-02562 REV.- PART 1. WORK WAS ACCOMPLISHE D BY MECH V919728. INITIATE DISDR CALA2019041200556Skin · dentedREF. LOG 8131062 AND EC/RA "5330-06448 REV A, 1 EA DENT ON FUS. SKIN AT L/H STA 610 JUST BELOW STRINGER 16L, REQUIRES PERMANENT REPAIR. REF ST SAA N/R 0059875 GAINED ACCESS, FABRICATED AND INSTALLED INTERM REPAIR AT L/H FUS ELAGE SKIN STA 610,STGR 16L IAW UNITSDR CALA2019040800543Gate · corrodedL-2 PASSENGER DOOR LWR GATE HAS CORROSION ON EXTE RIOR, AS MARKED. ST SAA N/R 0059961. L-2 DOOR LWR GATE FOUND OUT OF LIMITS IAW B757-200 SRM 52-10-02- A1 L=2.0, W=1.0, D=.038 REMOVED AND INSTALLED NEW L-2 DOOR LWR G ATE P/N 19-5210-3-0095 IAW DWG 140N6213 ANDSDR CALA2019040100507Angle · corrodedB757-49-3-8083 CORROSION BETWEEN APU AIR INLET DOOR HOUSING AND FUSELAGE SKIN CUTOUT. RL024. REF ST SAA N/R 0059696. REMOVED CORROSION ON APU AIR INLET BETWEEN STA 1787-1825 S-3R TO =1.0, D=.063, LWR ANGLE L=30.0, D=.063, W=1.0 OUT OF LIMITS IAW B757-200 SRM 5SDR CALA2019032500459Frame · dentedB757-06-3-0245 2EA DENTS ON AFT CARGO FRAME UPPER FLANGE AT STA 1520 BETWEEN STR 25L AND 26L. REF ON N/R CARD NO 0060021. ACCOMPLISHED REPAIR IAW SRM 53-00-07 REPAIR 5. INITIATED DIP TO ACCOMPLISH REINSPECTION AFTER 37500 FLIGHT CYCLES AFTER RER AIR OR 50000 TSDR CALA2018021600653Proximity Sensor · faultyL1 DOOR SLIDE LIGHT INOPERATIVE. REMOVED AND REPLACED THE GIRT BAR PROXIMITY SENSOR S10215 IAW MM 25-66-11. OPS CHECKED GOOD.SDR CALA2018021600652Proximity Sensor · dirtyL1 DOOR SLIDE ARM LIGHT DOES NOT ILLUMINATE WITH DOOR ARMED. CLEANED THE PROXIMITY SWITCHES, DOOR SLIDE ARM LIGHT OPS CKS GOOD IAW MM 25-66-00. ACFT OK TO CONTINUE.SDR CALA2018012900387Oven · odorGALLEYS GALLEY G4D - OVEN AT GALLEY DEFECTIVE (DESCRIBE DEFECT) CENTER OVEN WILL NOT TURN ON LEFT OVEN SMELLS OF BURNING PLASTIC. REPLACED NR 2 (CENTER) OVEN IAW AMM 25-34-00 OPS CHK GOOD.SDR CALA2018010800097Light · missingROW 3 ADJACENT SEAT B, EMERGENCY LIGHT MISSING. REPLACED THE LIGHT AND OP CHECKED GOOD.SDR CALA2017100603519Bulb · inoperativeFOUND THE R3 EMERGENCY DOOR SLIDE LIGHT INOPERATIVE. REPLACED THE BULB AND OPS CHECKED GOOD.SDR CALA2017091503194Slider · looseSLIDE AT THE L2 DOOR, THE GIRT BAR WAS FOUND LOOSE. ATTACHED THE GIRT BAR SLIDER IAW AMM 25-66-10-402-022. L2 DOOR ARMING GOOD. IAW AMM25-66-10-402-022, OPS CHECKED GOOD.SDR CALA2017042101049Relay · faultyACRID ELECTRICAL ODOR NOTED IN THE FLT DECK AND CABIN. COMPLIED WITH CONDITIONAL INSPECTION IAW AMM 05-51-58-910-801C1. NOTHING FOUND. COMPLIED WITH ENGINE RUN REQUIREMENTS, NO FAULTS NOTED. FOUND OVERWING HATCH HEATERS LT AFT, RT FWD AND RT AFT INOPERASDR CALA2016122701180Lamp · inoperativeEMERGENCY EXIT LIGHT ARMED, BULB ON OVERHEAD PANEL INOPERATIVE. REPLACED THE LAMP. OPS NORMALSDR CALA2016120501025Light · inoperativeSEAT 36ABC EEL AISLE LIGHT INOP. REPLACED SEAT 36ABC AISLE EEL WHITE LIGHT, REF PATHFINDER EMERGENCY ESCAPE PATH LIGHTING SYSTEM DRAWING BR2013-P-7572CO-5 REV B. OPS CHECK GOOD.SDR CALA2016120501024Battery Pack · dischargedEMERGENCY EXIT LIGHTS OUT FROM ROW 31 AFT OUT. REPLACED M736 EMERGENCY POWER SUPPLY CHARGER AND BATTERY PACK, REF AMM 31-51-07. OPS CHECK OF EMERGENCY ESCAPE LIGHT SYSTEM, INCLUDING ALL SEATS GOOD.SDR CALA2016102800827Light · inoperativeEMERGENCY RT AFT SERVICE DOOR INOP. RELAMPED OPS CHECKED NORMAL.SDR CALA2016042200245Hydraulic Line · leakingLOST ALL OF LEFT SYS HYD FLUID ON DEPARTURE. FOLLOWED QRH. REPLACED LEAKING HYD PRESS LINES & EDP. NO LEAKS NOTED.SDR CALA2016032100177Frame · dentedFORWARD CARGO FRAME DENTED BS 680, STRINGER 24R. INSTALLED FRAME J REPAIR AT BS 680, BETWEEN STRINGER 23R - 25R IAW SRM 53-00-07 REPAIR 5 DETAIL II.SDR CALA2016032100176Frame · dentedFORWARD CARGO FRAME DENTED BS 660, STRINGER 24R. INSTALLED FRAME J REPAIR AT BS 660, BETWEEN STRINGER 23R - 25R IAW SRM 53-00-07 REPAIR 5 DETAIL II.SDR CALA2016021900117Unknown · odorFLIGHT ATTENDANTS REPORTED STRONG ELEC SMELL IN AFT GALLEY, AFTER ENG START. SMELL DISSIPATED AFTER SHUTDOWN. ACCOMPLISHED INITIAL & DETAILED INSPECTIONS & OPERATIONAL CHECKS IAW AMM 05-51-58 & ADDITIONAL INSPECTIONS ACMP.SDR CALA2016012500065Stiffener · chafedPASSENGER CABIN, STATION 1640, STRINGER 11L & 13L, STIFFENER & WEB ARE CHAFED. BLENDED OUT DAMAGE SECTION ON STIFFENER, ORIGINAL MAT .200", , MAT LOSS .020", MAT REMAINING .180", WITHIN LIMITS IAW SRM 53-60-15 DETAIL VI & DWG 146N8738. CUT OUT DAMAGED AREA, SDR CALA2016010400003Charger · inoperativeL4 DOOR SLIDE LIGHT ON FUSELAGE INOPERATIVE. REPLACED BATTERY CHARGER IAW AMM 33-51-07-862-054. OPERATIONS CHECKED GOOD. ACFT RELEASED FOR FLIGHT.SDR CALA2012040900248Socket · inoperativeEXTERIOR EMERGENCY LIGHT AT R3 DOOR IS OUT. TROUBLESHOT IAW WDM 33-51-15. REMOVED AND REPLACED DOOR 3R EXTERIOR EMERGENCY LIGHT SOCKET IAW AMM 33-51-06. OPS CHECKED GOOD.SDR CALA2012040900247Socket · inoperativeEXTERIOR EMERGENCY LIGHT AT L3 DOOR IS OUT. TROUBLESHOT IAW WDM 33-51-15. REMOVED AND REPLACED DOOR 3 LEFT EXTERIOR EMERGENCY LIGHT SOCKET IAW AMM 33-51-06. OPS CHECKED GOOD.SDR CALA2011071400490Plate · out of adjustAFT T-OFF DOOR 4L EICAS MSG ON-THE DOOR HANDLE WAS MOVING TOWARDS OPEN POS. CORRECTED AC NUMBER FROM 138 TO 135. FOUND GUIDE DOORS OUT OF ALIGNMENT, ADJUSTED GUIDE PLATES ON FRAME, OPS CHECK DOOR PER MM 11-00-825-001.SDR CALA2010031600081Skin · crackedFWD CARGO DOOR EXTERIOR LOWER CORNER SKIN CRACKED AND WORN. BLENDED OUT DAMAGE & INSTALLED REPAIR DOUBLER ON THE AFT LOWER CORNER OF THE FWD CARGO DOOR SKIN REF SRM 52-30-01 REPAIR 4. INITIATED A DIP TO REINSPECT REPAIR AT A THRESHOLD OF 37,500 TOTAL FLIGHT SDR CALA2010031600080Doubler · damagedEXISTING REPAIR DOUBLER AT APPROXIMATELY STA 320 BETWEEN STRINGERS 22RT AND 23RT HAS SEVERAL DINGS ON THE AFT END. REMOVED EXISTING DOUBLER, CUT OUT ADDITIONAL DAMAGE & INSTALLED NEW REPAIR DOUBLER REF SRM 53-00-01 REPAIR 2. INITIATED A DIP TO HFEC INSP SKINSDR CALA2010030800061Floorbeam · corrodedAFT FLOORBEAM STA 1640 FROM LBL 4 TO RBL 4 HEAVY CORROSION. REPAIRED UPPER FLOORBEAM CAP REF SRM 53-00-51 REPAIR 3.SDR CALA2010030800058Floor Support · corrodedFLOOR SUPPORT HAS CORROSION, STA 680, RBL 38, JUST AFT OF THE O/B AFT G2A GALLEY MOUNT. DEPTH OF CORROSION MORE THAN 10 PERCENT MAX ALLOWABLE LIMITS. REMOVED AND REPLACED FLOOR SUPPORT INTERCOSTAL STA 680, RBL 38 JUST AFT OF THE O/B - AFT G2A GALLEY REF BOEISDR CALA2010022600053Floorbeam · corrodedB757-53-3-0007 FLOORBEAM STA 720 HAS HEAVY CORROSION AT UPPER CAP FROM L2 DOOR THRESHOLD TO R2 DOOR THRESHOLD. REMOVED AND REPLACED UPPER FLOORBEAM CAP AT STA 720 FROM L2 DOOR THRESHOLD TO R2 DOOR THRESHOLD REF B757 SRM 51-40-02 AND EA 5320-01454.SDR CALA2009030900127Tpu · failedON CLIMBOUT AT APPROX 1500FT MSL ENCOUNTERED MULTIPLE COMPRESSOR STALLS ON RT ENG, PASSENGERS ON RT SIDE OF A/C OBSERVED SPARKS AND FLAMES FROM RT ENG INTAKE. OPERATED ENG AT REDUCED THRUST, RETURNED FOR LANDING, PERFORMED FIM TASK 71-06-00. REMOVED AND REPLSDR CALA0400721Skin · corrodedINSPECTION FOUND FUSELAGE SKIN CORRODED BELOW APU BLEED DUCT BETWEEN BS 1825 AND 1844, S25L TO 27L. THE SKIN WAS REPAIRED IAW ERO 3432.SDR CALA0400174Support Fitting · corrodedINSPECTION FOUND FORWARD CARGO DOOR CUTOUT LOWER SILL UPPER AFT SUPPORT FITTING CORRODED. THE SUPPORT FITTING WAS REMOVED AND REPLACED IAW SRM 51-40-02.
Back to N41135