N416YX

Service difficulty reports · 23

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N416YX' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR R61A2025030200120Sensor · inoperativeLG WOW SYSTEM FAIL IN FLIGHT. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. SERVICED LH, RG, AND NOSE LANDING GEAR STRUTS.Mar 2, 2025 · N416YX · Emb ERJ170200LR · Landing Gear Position and WarningSDR R61A2025021800095Crossbeam · corroded"FWD WET AREA CROSS FRAME 17 CORRODED BETWEEN SEAT TRACKS AS MARKED. FABRICATED AND INSTALLED DOUBLER AND FILLER FOR REPAIR ON FWD WET AREA CROSS FRAME 17. REF EMB SRM 53-00-10 /REPAIR 03P"Jan 30, 2025 · N416YX · Emb ERJ170100LR · Fuselage Main, StructureSDR R61A2025021800093Doubler · chafed"CHAFE DOUBLER AS MARKED ON LH INBD TR CENTER HEAT BLANKET. REPLACED CAFE DOUBLER REF: REPUBLIC AIRWAYS EA 170EA-78-31-0004MR_1 REV. 1"Jan 28, 2025 · N416YX · Emb ERJ170100LR · Engine Thrust ReverserSDR R61A2024080900347Hydraulic Line · leakingLOST HYDRAULIC 2 QUANTITY. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R HYDRAULIC LINE/HOSE IN LH MLG AREA.Aug 7, 2024 · N416YX · Emb ERJ170200LR · Hydraulic System, MainSDR R61A2020071400563Mount · corrodedMAJOR REPAIR: AFT MOUNTING FLANGE ON FUSELAGE FOR PANEL 195NL HAS CORROSION. REMOVED AND REPLACED AFT MOUNTING FLANGE PN: 170-92406-003 REF EMB SRM 51-40-08. SEE EAMS W/O H7380 SN 477 FOR WORK DETAILS. AIRCRAFT REMAINS IN HEAVY CHECK.Jul 7, 2020 · N416YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201804070470Skin · nickedWHILE IN HEAVY MX CHECK - FOUND LOWER SKIN NICKED EXTERNALLY FR 21 STR 26R. PERFORMED PERMANENT REPAIR WITH DOUBLER ON LOWER SKIN EXTERNALLY FR 21 STR 26R IN ACCORDANCE WITH, REF ETD2018-170-036273. - MAJOR REPAIR.Apr 7, 2018 · N416YX · Emb ERJ170200LR · Fuselage Main, Plate/SkinSDR R61A201804070469Closeout Panel · corrodedWHILE IN HEAVY CHECK - FOUND CORROSION ON FWD CARGO BEAM CLOSE OUT PANEL AS MARKED. REMOVED AND REPLACED FWD CARGO BEAM CLOSE OUT PANEL REF 175 AMM 53-01-43.Apr 7, 2018 · N416YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201804070468Seat Track · corrodedWHILE IN HEAVY CHECK - FOUND CORROSION AT FRAME 19 LEFT SIDE OF THE CENTER FLOOR, FORWARD FUSELAGE FLOOR STRUCTURE UNDER NUTPLATE AS MARKED AND LOCATED UNDER FLOORBOARD 225FLF. REMOVED DAMAGE BY PERFORMING SPLICE REPAIR ON THE LT SEAT TRACK AT FR19 AT UPPER CAApr 7, 2018 · N416YX · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR R61A201804070467Doubler · corrodedWHILE IN HEAVY CHECK - FOUND CORROSION AT FRAME 14 RIGHT SIDE OF FWD FUSELAGE FLOOR STRUCTURE JUST FORWARD OF SERVICE DOOR AS MARKED. REMOVED AND REPLACED FLOOR DOUBLER AT FRAME 14 RIGHT SIDE OF FWD FUSELAGE REF SRM 51-40-08.Apr 7, 2018 · N416YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201804070466Beam · corrodedWHILE IN HEAVY CHECK - FOUND CORROSION AT FR 87-88 LT CENTER BEAM AS MARKED. REMOVED AND REPLACED FR 87-88 LT CENTER BEAM, REF SRM 51-40-08.Apr 7, 2018 · N416YX · Emb ERJ170200LR · Fuselage Main, StructureSDR R61A201804070465Shear Panel · corrodedWHILE IN HEAVY CHECK - FOUND CORROSION AT FR 87 CENTER SHEAR PANEL LE AS MARKED. REMOVED AND REPLACED CENTER SHEAR PANEL AT FRAME 87 FLOOR STRUCTURE REF SRM 51-42-01.Apr 7, 2018 · N416YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201804070464Shear Panel · corrodedWHILE IN HEAVY CHECK - FOUND CORROSION AT FR 87 LT SHEAR PANEL LE AS MARKED. REMOVED AND REPLACED FR 87 LT SHEAR PANEL REF SRM 51-40-08.Apr 7, 2018 · N416YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201804070463Panel Support · corrodedWHILE IN HEAVY CHECK - FOUND CORROSION AT FR 89 RT OB PANEL SUPPORT AS MARKED. REMOVED AND REPLACED RT OB PANEL SUPPORT AT FR 89 REF SRM 51-40-08.Apr 7, 2018 · N416YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201804070462Panel Support · corrodedWHILE IN HEAVY CHECK - FOUND CORROSION AT FR 88 LT OB PANEL SUPPORT AS MARKED. REMOVED AND REPLACED OB SUPPORT PANEL FR 88 LT REF 51-40-08.Apr 7, 2018 · N416YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A201804070461Shear Panel · corrodedWHILE IN HEAVY CHECK - FOUND CORROSION AT FR 87 RT SHEAR PANEL LE AS MARKED. COMPLETE: REMOVED AND REPLACED RT SHEAR PANEL AT FRAME 87 FLOOR STRUCTURE REF SRM 51-42-01.Apr 7, 2018 · N416YX · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR R61A2018040448Slide · crackedCRACKED BACK BOARD ON FWD PAX DOOR SLIDE.Apr 4, 2018 · N416YX · Emb ERJ170200LR · Escape SlideSDR R61A201802160192Spda · malfunctionedLANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF. RETURNED TO FIELD, NO EMERGENCY DECLARED. REPLACED SPDA 1 SLOT 2 AND 7 IAW AMM 24-61-13, OPS CHECKED GOOD.Feb 16, 2018 · N416YX · Emb ERJ170200LR · Landing Gear Retraction/Extension SystemSDR R61A201702260177Indicator · false indicationMAINTENANCE REPORTED THAT THE R2 DOOR LOCKED INDICATOR, ARMED INDICATOR WAS READING INCORRECTLY. MAINTENANCE ADJUSTED THE R2 DOOR SLIDE INDICATOR IAW AMM AND OPS CHECKED GOOD.Feb 26, 2017 · N416YX · Emb ERJ170200LR · Service DoorsSDR R61A201608170482Cradle · crackedMAINTENANCE REPORTED THAT THE RIGHT AFT FLASHLIGHT HOLDER WAS CRACKED. MAINTENANCE REMOVED AND REPLACED RIGHT AFT FLASHLIGHT IAW AMM AND OPS CHECKED GOOD.Aug 17, 2016 · N416YX · Emb ERJ170200LR · Emergency EquipmentSDR R61A201606230393Slide · unserviceableCREW REPORTED THAT THE R1 DOOR SLIDE PRESSURE GAUGE WAS READING IN THE RED. ACFT WAS FLOWN VIA MAINTENANCE FERRY, WHERE MAINTENANCE R & R R1 SLIDE ASSY IAW AMM AND OPS CHECKED GOOD.Jun 23, 2016 · N416YX · Emb ERJ170200LR · Escape SlideSDR R61A201603020161Battery Pack · inoperativeCREW REPORTED THAT THE EMERGENCY LIGHT SWITCH DID NOT WORK. MAINTENANCE R & R NR 1 EMERGENCY LIGHT POWER UNIT IAW AMM AND OPS CHECKED GOOD.Mar 2, 2016 · N416YX · Emb ERJ170200LR · Emergency LightingSDR R61A201602250140Battery Pack · inoperativeCREW REPORTED THAT THE EMERGENCY LIGHTS WERE ILLUMINATED IN THE OFF POSITION UPON SHUTDOWN OF THE APU. AFTER REESTABLISHING ACFT POWER THE EMERGENCY LIGHTS WOULD NOT ILLUMINATE IN THE ON POSITION. MAINTENANCE PERFORMED FULL RECHARGE OF THE EMERGENCY BATTERIEFeb 25, 2016 · N416YX · Emb ERJ170200LR · Emergency LightingSDR R61A201507270463Glowstrip · crackedMAINTENANCE REPORTED THAT THE PHOTOLUMINESCENT STRIP AT 16C WAS CRACKED. MAINTENANCE R & R PHOTOLUMINESCENT STRIP IAW AMM AND OPS CHECKED GOOD.Jul 27, 2015 · N416YX · Emb ERJ170200LR · Emergency Equipment
Back to N416YX