Service difficulty report · Battery Pack · Emb ERJ170200LR

Difficulty date
February 25, 2016
Submitted
February 26, 2016
Operation
Air carrier
Aircraft
N416YX
Make and model
Emb ERJ170200LR
Aircraft serial
17000381
Aircraft time
5,884 hours, 4,259 cycles
Part
Battery Pack
Condition
Inoperative
Location
Emergency Light
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW REPORTED THAT THE EMERGENCY LIGHTS WERE ILLUMINATED IN THE OFF POSITION UPON SHUTDOWN OF THE APU. AFTER REESTABLISHING ACFT POWER THE EMERGENCY LIGHTS WOULD NOT ILLUMINATE IN THE ON POSITION. MAINTENANCE PERFORMED FULL RECHARGE OF THE EMERGENCY BATTERIES IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.