N427UA
Service difficulty reports · 123
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N427UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N427UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013052803639Hydraulic Line · leakingFOUND HYD LINE LEAKING AT LT MLG WHEEL WELL CEILING AREA. REPAIRED, OK REPAIR. REF GPM 1-0-13-028. LEAK CHECKED OK.SDR UALA2013040402247Transceiver · failedNR 1 RADIO FAILURE. REPLACED NR 1 VHF COM AND GROUND TEST GOOD.SDR UALA2013032601918Connector · unsecureEMERGENCY LIGHT TEST FAILED. RESEATED CONNECTOR ON LEFT OVERWING EMERGENCY LIGHT POWER SUPPLY AND TEST PASSED.SDR UALA2013032601919Eec · faultyDURING ENGINE SHUTDOWN AT GATE, NR 2 FADEC MAINTENANCE MESSAGE DISPLAYED. REPLACED NR 2 ENGINE EEC. RAN ENGINE. OPS CHECKED GOOD.SDR UALA2013022001013Interface Unit · faultyDUE TO CHRONIC CH5098, PER TOMC REQUEST REMOVE AND REPLACE LGCIU1. REMOVED AND REPLACED LGCIU 1 PER TOMC REQUEST FOR CH5098 CALLOUT. DONE IAW AMM TASK 32-3 1-71-000&400-001-A AND 32-69-00-740-001-A LGCIU 1 BITE CHECK.SDR UALA2013021100799Slide · unwanted deployL1 DOOR SLIDE DEPLOYED. REPLACED DOOR SLIDE PER MM.SDR UALA2013011400202Oxygen Mask · unknownCAPTAINS O2 MASK DOES NOT PRESS TO TEST. CLOSED CAPTAINS O2 PROPERLY, SYSTEM OPS CHECKED NORMAL.SDR UALA2013010900134Windshield · damagedVISIBILITY THROUGH FWD COCKPIT WINDOWS IMPAIRED DUE TO HAZY COATING. REPLACED CAPT'S SIDE WINDSHIELD.SDR UALA2012112806841Valve · faultyHOT AIR FAULTS. REFERENCE REPEAT HOT AIR FAULTS TSM 21-63-00-810-849A PLEASE REPLACE THE TRIM AIR PRESSURE REGULATING AND SHUTOFF VALVE AS PROBLEM IS INTERMITTENT. VALVE PCN 644-0100 SEALS, PCN 751-0089 2EA IPC 21-63-03-05-070A AND ITEM 90 SEE AMM 21-63-19-4SDR UALA2012112606789Actuator · faultyCABIN TEMP IS IMPOSSIBLE TO CONTROL. CONSTANT COMPLAINTS FROM PAX. REPLACED RT RAM OUTLET ACTUATOR, OPS CHECK NORMAL.SDR UALA2012101905977Engine · bird ingestionFOUND EVIDENCE OF BIRD STRIKE ON NR 1 ENGINE INLET AT 2:00 POS AND 1:00 ON ENGINE CORE. FOUND NO EVIDENCE OF RUBBING ON THE FAN ATTRITION LINERS. FOUND NO DAMAGE ON THE FAN BLADES. NI ROTATION OK ENGINE NR 1 SERIAL V10483 REQUIRES LPC AND HPC BORESCOPE INSPSDR UALA2012082704802Manifold · leakingHYD LEAK COMING FROM D&E B-NUT ON THE LEAKAGE MEASUREMENT SELECTOR VALVE IN THE UPPER RT SIDE WHEEL WELL. TIGHTENING B-NUTS HAS NO EFFECT, SUSPECT BAD LINES. LEAK COMING FROM BACKSIDE OF MANIFOLD, NEW PART 644-1005 ON AOG N3467. REPLACED GROUND LEAKAGE-MEASSDR UALA2012082404761Starter · faultySTART FAULT DISPLAYED ON UPPER ECAM SCREEN. HUNG START. - ENG 1 CREW COMMENTS: SUBSEQUENT MANUAL START FAILED. DISPLAYED CHECK BLEED SUPPLY PROG TEXT: - ITEM ROLLED FORWARD. SAMC TEXT: FLT CREW REPORTS THAT SPARKS WERE REPORTED BY PUSH CREW DURING INITIAL SDR UALA2012082404749Connector · looseEMERGENCY LIGHT OUT AT SEAT 24C. FOUND CONNECTOR LOOSE, SECURED CONNECTOR. OPS CHECK OK.SDR UALA2012081004348Transceiver · failedNR 1 RADIO WEAK AND UNREADABLE. REPLACED NR 1 VHF TRANSCEIVER. CHECKED OK.SDR UALA2012050302614Apu · malfunctionedAPU FAILED TO START 3 TIMES ON TAXI IN. OPS CHECKED IAW AMM 49-0 0-00-201. STARTED 4 TIMES, BOTH PACKS OPERATED, IGNITION, EGT ALL NORMAL.SDR UALA2012050302609Apu · malfunctionedAPU FAILED TO START 3 TIMES ON TAXI IN. OPS CHECK IAW AMM. STARTED 4 TIMES, BOTH PACKS OPERATED, IGNITION, EGT ALL NORMAL.SDR UALA2012031901752Slat · damagedDAMAGE FOUND ON LT NR 2 SLAT. REPLACED NR 2 SLAT.SDR UALA2012031901743Switch · stuckEMERGENCY EXIT LIGHT SWITCH STUCK IN OFF POSITION. REPLACED EMERGENCY EXIT LIGHT SWITCH 4WL, CHECKS GOOD.SDR UALA2012021000811Module · faultyF-CTL ELAC 2 PITCH FAULT DISPLAYED ON ECAM SAMC TEXT: CREW REPORTS "THS ACTR MOTOR 1" CB TRIPPED. "ELECTRONIC MODULES" (PCN 565-1450) AND ASM 27-44-57. SWAP NR 1 AND 3 MODULES. IF CB 19CE1 REMAINS IN, APPLY MEL. SWAPPED NR 1 AND 3 MODULES NR 1 SYSTEM OPS SDR UALA2012012700557Stringer · corrodedSTR 31R AT FRAMES 65 AND 66 IS CORRODED BELOW OUTFLOW VALVE. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRINGER IAW SRM 51-42-11. PANEL 162CW INSTALLED PER SRM 51-42-11. RIVETS HEAT TREATED PER UAL GNMM 1-0-7-003 REF NR E4327I.SDR UALA2011110906095Tire · low pressureAIRCRAFT PULLS RIGHT WILL NOT TRACK STRAIGHT. FOUND RT NOSE TIRE 40 PSI LOWER THAN THE LT NOSE TIRE. REPLACED BOTH NOSE TIRES PER AMM.SDR UALA2011102705823Bearing · brokenAFT CARGO DOOR OPENING HANDLE BROKEN. MAIN ATTACH POINT SHEARED. REMOVED DOOR HANDLE ASSY. REPLACED AFT CARGO DOOR HANDLE ASSY PER MM. ACCOMPLISHED INSPECTION OF AFT CARGO DOOR HANDLE INSTALLATION, FOUND SECURE AND OPS CHECKED OKAY.SDR UALA2011052402541Windshield · crackedRIGHT WINDOW ANTI ICE DISPLAYED ON UPPER ECAM SCREEN. RIGHT WINDSHIELD HAS 15 INCH CRACK LOWER RIGHT QTR OUTER PANE. REPLACED F/O'S WINDSHIELD, OPS CHECKED GOOD.SDR UALA2011031601286Control Unit · malfunctionedA-C PULLS TO RIGHT ON TAXI. CONTINUOUS LEFT TILLER REQ TO TRACK STRAIGHT. MAINT TEXT: DURING TAXI TEST LEFT RUDDER TRIM REQUIRED TO KEEP AIRCRAFT STRAIGHT. REPLACED BSCU PER MM. TAXIED AIRCRAFT WITH ALLOWABLE TRIM INPUTS OF UP TO 3 DEGREES TO STEER STRAISDR UALA2011020800671Solenoid · faultedREGULATOR LOW PRESSURE MESSAGE DISPLAYED ON LOWER ECAM WHEN MASKS ARE TESTED. REPLACED PRESSURE SWITCH 4WV IAW MM, NO HELP. REPLACED OXYGEN PRESSURE REGULATOR 4HT IAW MM (TWICE). NO HELP. PILOT REPORTED "ALONG WITH MESSAGE, WE DO NOT GET ENOUGH OXYGEN FROMSDR UALA2011012000337Regulator · failedCREW REPORTED REG LOW PRESSURE INFORMATION ON THE DOOR-OXY PAGE. CREW ALSO STATED MASK IS NOT GIVING FULL PRESSURE WHEN DEMANDED. ACCOMPLISHED OPS CHECK IAW AMM FOR MASKS AND TSM TASK. REPLACED TRANSMITTER REGULATOR 4HT IAW AMM. ACCOMPLISHED LEAK CHECK AND OSDR UALA2010120304444Controller · malfunctionedPACK FLOW, NR 2 PACK STUCK IN LOW FLOW. CONCERRED WITH OPBLM, SEVERAL PAST LEG HITS ON P1 CONTROLLER (7HH) 565-9009 WHICH *MAY* BE CAUSING PACK 2 FLOW PROBLEMS. SWAPPED OUT CONTROLLERS, PROBLEM CONTINUED ON NR2 PACK, REINSTALLED CONTROLLERS IN ORIGINAL POSITISDR UALA2010111904277Oxygen Mask · unwanted deployO2 MASK DEPLOYED OVERAFT FLIGHT ATTENDANT JUMPSEAT, INOP AFT FLT ATTENDANT SEATS, RESTOWED AFT FLIGHT ATTENDANT O2 MASK. ACCOMPLISHED OPERATIONAL CHECK OF THE MANUAL MASK RELEASE.SDR UALA2010081602973Computer · malfunctionedBLOWER FAULT DISPLAYED, FLIGHT DIVERTED. PFR SHOWING FAULT ON THE AEVC. REPLACED THE AEVC PER AMM AND BITE TEST OKAY.SDR UALA2010061702135Control Unit · malfunctionedBRAKING ABNORMAL. CREW LOST BSCU 1 AND NOSE WHEEL STEERING ON LANDING. BSCU 2 ALREADY DEFERRED. POST FLIGHT REPORT POINTS TO BAD BSCU. REPLACED BSCU, CHANNEL 1 & 2 BITE TEST PASS.SDR UALA2010052501798Bottle · out of toleranceCREW O2 BOTTLE PRESSURE GAUGE OUT OF DATE. REPLACED CREW O2 BOTTLE AND ACCOMPLISHED SUCCESSFUL LEAK CHECK OF FITTINGS.SDR UALA2010030100722Microphone · failedF/O ACP INOP, GET HOT MIKE WITH MINITEL PLUGGED IN, NO SPEAKER OR HAND MIKE CAPABILITY. MECH FOUND F/O INTERPHONE WITH LOUD FEEDBACK AND NO 02 MASK FUNCTION. SWAPPED MINITEL WITH CAPT SIDE, FAULT FOLLOWED. REPLACED F/O MINITEL WITH SPARE AND REINSTALLED CAPT SDR UALA2010021900626Priority Valve · lockedLOST NR 1 AND NR 2 ENGINE BLEEDS, FLIGHT DIVERTED. MX INSPECTED BOTH ENGINES, FOUND NR 2 PRV LOCKED CLOSED. DETERMINED NR 1 BLEED TRIP AND OVERTEMP TO BE CAUSED BY NR 2 ENGINE PRV BEING LOCKED OUT WITH DUAL PACK OPS. HAD MCI MX OPEN COWLING AND INSPECT NR 2 SDR UALA10020300435APower Supply · faultyNO CONTROL OVER CABIN LIGHTING FROM CIDS PANEL. EMERGENCY LIGHT STAY ON ALL THE TIME REGARDLESS OF SWITCH POSITIONS. STILL TROUBLESHOOTING. REPLACED 10WL POWER SUPPLY (P/N 3214-54) AND CIDS PANEL, NO HELP. REPLACED CPC NR 1, DEU 300RH4, DEU 300RH5. NORMALSDR UALA2009060101557Battery · inoperativeTWO EA EMERGENCY FLASHLIGHTS ONE FWD ONE AFT NOT WORKING. REPLACED BATTERIES, OPS CKS GOOD. RESEALED FLASHLIGHTS.SDR UALA2009031000618Panel · delaminatedPYLON FAIRING PANEL DELAMINATED. RTFL. REPLACED FILLET FAIRING.SDR UALA2009022300618Panel · delaminatedPYLON FAIRING PANEL DELAMINATED. RTFL.SDR UALA2009011900186Smoke Detector · false activationCREW REPORT: RECEIVED A FWD LAV SMOKE INDICATION. FLIGHT DIVERTED. CREW REPORT: RECEIVED A FWD LAV SMOKE INDICATION. NO VISIBLE SMOKE PRESENT. ALARM WAS RESET ON CIDS PANEL. FAULT WAS ACTUALLY WITH LAV F, WHICH IS AFT MOST LAV. INSPECTED AREA FOR ANY DISSDR UALA2008120106689Fcu · faultyAUTOPILOT ISSUES. FLIGHT DIVERTED. AUTO FLT 'FCU 1+2 FAULT' DISPLAYED ON UPPER ECAM SCREEN. CYCLED CB B5 AND M21 AND FCU CHANNEL 1 RECOVERED BUT FCU CHANNEL 2 REMAINED INOP. REPLACED FCU.SDR 2008UALA06370Battery · dischargedFAILED EMERGENCY LIGHT SYSTEM TEST REF MM 33-51-00-710-001. MESSAGE: EMER SYSTEM ATA 33-51-38 BATTERY EMER R. REPLACED BATTERY FOR RIGHT MID CABIN. OP'S CHECK GOOD. EMER LIGHT SYS TEST PASSED.SDR 2008UALA05873Bottle · low pressureDOOR 2L 1300 PSI - LOW. SERVICED DOOR 2L TO PROPER PRESSURES.SDR 2008UALA04159Drain Valve · leakingHYDRAULIC GREEN SYSTEM LOW LEVEL DISPLAYED. FOUND DRAIN VALVE LEAKING. REPLACED DRAIN VALVE AND SERVICED HYD SYSTEM. OP CHECKS NORMAL.
SDR 2008UALA02773Bleed Valve · malfunctionedNR 1 ENGINE HIGH PRESSURE BLEED VALVE PROBLEM CAUSED A DIVERSION.SDR 2008UALA01571Cover · missingSEAT 23C IS MISSING EMERGENCY LIGHT COVER. REPLACED MISSING LIGHT COVER.SDR 2008UALA01570Cover · missingSEAT 15C IS MISSING EMERGENCY LIGHT COVER. REPLACED MISSING COVER.SDR 2008UALA00991Circuit Breaker · out of toleranceEXT LOAD EMERGENCY LEFT, AND INTERNAL LOAD EMERGENCY LEFT MESSAGE ON EMERGENCY LIGHT TEST. RESET EMERGENCY LIGHT CIRCUIT BREAKER, OPS CHECKED GOOD.SDR 2008UALA00935Regulator Valve · leakingCOCKPIT OXYGEN BOTTLE - LOW CREW COMMENTS: COCKPIT OXYGEN PRESSURE SLOW LEAK LOSING 100 PSI - HOUR IN FLT. LEAK AT PRESSURE REGULATOR. REPLACED PRESSURE REGULATOR, SERVICED CREW O2, LEAK CHECKED SYSTEM, ALL OK.SDR 2007UALA05223Oxygen System · low pressureCREW OXYGEN SYSTEM - LOW. RECORD PRESSURE PRIOR TO SERVICING. SERVICED CREW O2 SYSTEM TO PROPER OPERATING PRESSURE.SDR 2007UALA05224Oxygen Mask · faultyF/O'S O2 MASK YELLOW CAT EYE REMAINS DISPLAYED AFTER TEST. FOUND WORN COVERPLATE AND DETERIORIZATION OF RUBBER ON MASK BANDS, HOSES. MASK WAS REPLACED WITH NEW OUT STOCK. CREW O2 SERVICED.
Back to N427UA