N429UP
Service difficulty reports · 247
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N429UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N429UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA10562253Web · damagedINSPECTION TYPE:C2, WHILE WORKING JOB CARD 870610, FOUND FASTENER HOLE DAMAGED IN WEB AT BS 570 LBL 48. REPAIRED IAW ER 10-3927, DATED 26AUG2010.SDR IPXA10561553Floorbeam · corrodedINSPECTION TYPE:C2, MCB FLOOR SUPPORT PLATE HAS CORROSION ON UPPER SURFACE BS 1017, RBL 26 TO RBL 42, WL 208. REPLACED IAW SRM.SDR IPXA10562243Shear Web · corrodedINSPECTION TYPE:C2, MAIN CARGO SHEAR WEB HAS AREA OF CORROSION ON UPPER SURFACE BS 475-480, LBL 48-51, WL 208. REPAIR IAW ER 10-3672.SDR IPXA10562236Shear Web · corrodedINSPECTION TYPE:C2 SHEAR WEB IS CORRODED BS 466 TO 470 LBL 50 TO LBL 57. BLENDED AND REFINISHED PER ATS ER 10-3672SDR IPXA10561865Floorboard · damagedINSPECTION TYPE:C2, FLOOR SUPPORT AT BS 1055, FOUND HOLES IN FLOORBOARD PANEL BS 1055-1100, RBL 0-25 HAVE SHORTED. FABRICATED FLOORBOARD PANEL AT BS 1055-1100, RBL 0-25 IAW EO B757-5320-9692-G.SDR IPXA10561532Floor Panel · damagedINSPECTION TYPE:C2, UPON INSTALLATION OF MCB FLOOR SUPPORT AT BS 1055, FOUND HOLES IN FLOOR PANEL BS 1020-1055 RBL 0-25 TO HAVE SHORT EDGE DISTANCE AT BS 1055. FABRICATED REPLACEMENT FLOOR PANEL.SDR IPXA10561482Floor Panel · delaminatedINSPECTION TYPE:C2, MAIN DECK FLOOR PANEL 820-879, LBL 45-61 CORNER DELAMINATED. FABRICATED NEW MAIN DECK FLOOR PANEL BS 820-879, LBL 45-60 IAW EO B757-5320-9692G.SDR IPXA0561360Skin · dentedINSPECTION TYPE:C2 DENT UPPER RT SIDE OF EMPENNAGE AT BS 1969. REPAIRED EMPENNAGE UPPER RT SIDE AT BS 1969 IAW SRM 51-70-10-2R.SDR IPXA10561479Floorboard · debondedINSPECTION TYPE:C2, FLOORBOARD DEBONDED, BS 440-480, BL 45R TO BL 60R. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA10561408Floor Panel · misrepairedINSPECTION TYPE:C2, VALIDATE REPAIR ON FLOOR PANEL IN POSITION 1 BS 333-440, RBL 45-65. FABRICATED NEW FLOOR PANEL IAW EO NR B757-5320-9692-G.SDR IPXA10562241Strap · corrodedINSPECTION TYPE:C2, CORROSION ON SPLICE STRAP FROM BS 488-491 LBL 46-47, WL 208. REPAIR IAW ER 10-3672.SDR IPXA10561543Floor Support · gougedINSPECTION TYPE:C2, FLOOR SUPPORT UPPER SURFACE GOUGED BS 300-309, RBL 13, WL 208. REMOVED, FABRICATED, INSTALLED REPLACEMENT FLOOR SUPPORT SRM 51-10-02, 53-10-51-07, 53-00-51-1A1.SDR IPXA10562248Frame · dentedINSPECTION TYPE:C2, FRAME DENTED IN FWD CARGO BAY BS 660 BETWEEN STR 24R - STR 25R. REPAIRED IAW PF SRM 53-00-07-2R-5, DETAIL III.SDR IPXA10562239Seat Track · corrodedINSPECTION TYPE:C2 MAIN DECK HAS CORROSION AT BS 874, BL 0 AROUND UPPER FLANGE FASTENER HOLE ON SEAT TRACK. REPAIR IAW ATS ER 10-3983SDR IPXA10562224Seat Track · corrodedINSPECTION TYPE:C2 SEAT TRACK OB FLANGE HAS CORROSION BS 580-620 LBL 1. REPAIRED PER ER 10-3714 DATED 25AUG10SDR IPXA10562223Floorbeam · damagedINSPECTION TYPE:C2, FLOORBEAM AFT FLANGE BS 560 HAS DAMGED HOLES LBL 5-14. REPAIRED IAW ER 10-3797.SDR IPXA10562204Seat Track · corrodedINSPECTION TYPE:C2, MAIN DECK HAS CORROSION AT BS 874, BL 0 AROUND UPPER FLANGE FASTENER HOLE. REPAIRED IAW ER 10-3983, DATED 25AUG10.SDR IPXA10562120Shear Web · corrodedINSPECTION TYPE:C2, FLOOR SHEAR WEB HAS MULTIPLE AREAS OF CORROSION BS 1680 -1720, BL 0 - LBL 65, WL 208. REPAIRED IAW ATS ER10-3731, DATED 8-18-10.SDR IPXA10562118Shear Web · corrodedINSPECTION TYPE:C2, FLOOR SHEAR WEB HAS MULTIPLE AREAS OF CORROSION, BS 1680-1720, BL 0 - RBL 65, WL 208. REPAIRED IAW ATS ER 10-3731, DATED 8-20-10.SDR IPXA10562103Shear Web · corrodedINSPECTION TYPE:C2, THE SHEAR WEB UPPER SURFACE HAS CORROSION BS 340 LBL 27.5, WL 208 AT A NUTPLATE HOLE. REPLACED IAW ATS ER 10-3667, DATED 8-18-10.SDR IPXA10562093Frame · dentedINSPECTION TYPE:C2, FRAME DENTED IN FWD CARGO BAY BS 680, BETWEEN STR 24L - STR 25L. REPAIRED IAW SRM 53-00-07-2R-5, DETAIL III.SDR IPXA10562079Shear Web · corrodedINSPECTION TYPE:C2, THE SHEAR WEB UPPER SURFACE HAS CORROSION BS 336-340 LBL 47-61, WL 208 AT A NUTPLATE HOLE. REPAIRED PER ATS ER NR10-3715, DATED 8-13-10.SDR IPXA0562025Frame · dentedINSPECTION TYPE:C2, FRAME DENTED IN FWD CARGO BAY AT BS 820, STR 24L. REPAIRED FRAME AT BS 820, STR 24L IAW SRM 53-00-07-1A1, SRM 53-00-07-2R5, SRM 51-40-02-0G, DWG 140N2002, SHT 158, SRM 51-30-01-0G, DWG 65-88700 SH 1, SRM 51-40-05-0G.SDR IPXA0561981Frame · dentedINSPECTION TYPE:C2, FRAME DENTED IN FWD CARGO BAY AT BS 740, BETWEEN STR 24L - STR 25L. REPAIRED IAW SRM 53-00-07-2R5.SDR IPXA0561979Seat Track · corrodedINSPECTION TYPE:C2, CORROSION ON SEAT TRACK OTBD FLANGE BS 575 -620, LBL 25 CORRODED AREAS FOUND OUT OF LIMITS, REPAIR IAW SRM 53-00-52-2R5.SDR IPXA0561948Shear Web · corrodedINSPECTION TYPE:C2, SHEAR WEB UPPER SURFACE HAS CORROSION BS 324-335, LBL 47-61, WL 208. REPAIRED IAW ER NR10-3733 DATED 05AUG2010.SDR IPXA10561885Shear Web · corrodedINSPECTION TYPE:C2, THE COCKPIT FLOOR UPPER SURFACE IS CORRODED BS 277-5, LBL 1, WL 197. REPAIR IAW ER 10-3646.SDR IPXA10561882Shear Web · corrodedINSPECTION TYPE:C2, THE COCKPIT FLOOR UPPER SURFACE IS CORRODED BS 285.5 RBL 1.5, WL 197. REPAIR IAW ER 10-3646.SDR IPXA10561546Floor Support · gougedINSPECTION TYPE:C2, THE FLOOR SUPPORT UPPER SURFACE IS GOUGED BS 310-324, RBL 13, WL 208. GOUGED AREA FOUND TO BE OUT OF LIMITS, REPLACED IAW SRM 51-10-02, SRM 53-10-51-01I, SRM 53-00-51-1A1, SRM 51-40-02-0G.SDR IPXA10561542Floorbeam · corrodedINSPECTION TYPE:C2, FLOORBEAM UPPER CHORD HAS CORROSION BS 297, LBL 11, WL 208. REMOVED, FABRICATED AND INSTALLED IAW SRM51-40-02, AND SRM 53-10-51-0I 1.SDR IPXA10561529Floor Panel · puncturedINSPECTION TYPE:C2, THE MAIN CARGO BAY FLOOR PANEL BS 1420-1540 RBL 45-60 IS PUNCTURED ON TOP. REPLACED MAIN CARGO FLOOR PANEL IAW EO B757-5320-9692-G AND EO B757-5100-33281B.SDR IPXA10561528Floor Panel · damagedINSPECTION TYPE:C2, THE MAIN CARGO BAY FLOOR PANEL BS 1681-1720, BL 0-RBL 6 HAS 4 DAMAGED INSERTS. FABRICATED REPLACEMENT FLOOR PANEL.SDR IPXA10561439Floor Panel · corrodedINSPECTION TYPE:C2, MAIN DECK FLOOR PANEL BS 720-820, LBL 25-45 CORE HAS CORROSION. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10561431Floor Panel · delaminatedINSPECTION TYPE:C2, MAIN DECK FLOOR PANEL BS 720-820 LBL 45-61 DELAMINATED. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA10561421Floor Panel · damagedINSPECTION TYPE:C2, MAIN DECK FLOOR PANEL BS 720-820, RBL 45-61 HAS EDGE DAMAGE. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-GSDR IPXA0561391Floor Panel · damagedINSPECTION TYPE:C2, THE MAIN CARGO BAY FLOOR PANEL BS 1600-1681, RBL 45-60 HAS 1 DAMAGED INSERT. REPLACED IAW UPS EO B757-5320-9692-G & EO B757-5100-33281-B.SDR IPXA0561387Floor Panel · damagedINSPECTION TYPE:C2, MCB FLOOR PANEL HAS DAMAGE TO LOWER SURFACE, BS 1020 TO BS 1055, BL 0 TO LBL 25, WL 208. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA0561386Floor Panel · delaminatedINSPECTION TYPE:C2, MAIN CARGO FLOORBOARD BS 620-720, BL 0-LBL 25, WL 208 IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA0561384Floor Panel · corrodedINSPECTION TYPE:C2 MAIN CARGO FLOOR BOARD BS 620-720, LBL 25-LBL 45, WL 208 HAS CORRODED CORE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA0561378Floor Panel · damagedINSPECTION TYPE:C2, MAIN DECK FLOOR PANEL BS 879-900, RBL 45-61 HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO#B757-5320-9692-GSDR IPXA0561377Floor Panel · delaminatedINSPECTION TYPE:C2, MAIN CARGO FLOORBOARD BS 560-620, BL0-LBL25, WL208 IS DELAMINATED. FABRICATED NEW FLOOR PANEL EO B757-5320-9692-G.SDR IPXA0561376Floor Panel · damagedINSPECTION TYPE:C2, MAIN DECK FLOOR PANEL BS 820-879 RBL 45-61 HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA0561375Floorboard · delaminatedINSPECTION TYPE:C2, MAIN CARGO FLOORBOARD BS 560-620, LBL25-LBL45, WL 208 IS DELAMINATED. FABRICATED NEW FLOORBOARD IAW UPS EO B757-5320-9692-G.SDR IPXA0561373Floorboard · corrodedINSPECTION TYPE:C2, MAIN DECK FLOOR PANEL BS 820-879, BL0-LBL 25, CORE HAS CORROSION. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA0561372Floor Panel · corrodedINSPECTION TYPE:C2, MAIN DECK FLOOR PANEL BS 820-879, LBL 25-45 CORE HAS CORROSION. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692G.SDR IPXA0561363Floorboard · corrodedINSPECTION TYPE:C2, MAIN CARGO FLOORBOARD BS 620-720 BL 0-RBL 25 WL 208 HAS CORRODED CORE. R & R FLOORBOARD IAW EO B757-5320-9692-C.SDR IPXA0561362Floorboard · corrodedINSP TYPE:C2, MAIN CARGO FLOORBOARD BS 620-720, RBL 25-RBL 45, WL 208 HAS CORRODED CORE. R & R FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA10562255Frame · dentedINSPECTION TYPE:C2 FWD CARGO FRAME HAS DENT IN UPPER FLANGE BS 800, BETWEEN STR 24R-25R. REPAIRED IAW SRM 53-00-07-2R5.SDR IPXA10562240Shear Web · corrodedINSPECTION TYPE:C2, CORROSION, BS 530, LBL 49, WL 208, ON THE FLOOR SHEAR WEB. REPAIRED IAW ER 10-3672.SDR IPXA10562235Shear Web · corrodedINSPECTION TYPE:C2 CORROSION, BS 540, LBL 48-50, WL 208, ON FLOOR SHEAR WEB. BLENDED AND REFINISHED PER ATS ER 10-3672
Back to N429UP