N429UP
Service difficulty reports · 247
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N429UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N429UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2014121085034Lens · wornEXIT LIGHT LENS WORN. R & R LIGHT LENS WRT IPC 33-51-11-01, EFF SOURCE REF 33-51-11-01-010.SDR IPXA2014071683633Skin · gougedINSPECTION C-12, LT WING OTBD MAIN FLAP, INBD UPPER EDGE GOUGED. ACCOMPLISHED EO B757-5750-39142-A.SDR IPXA2014031782281Skin · dentedDENT IN FUSELAGE SKIN BS 492, BETWEEN S22 - 23R. REPAIRED IAW EO B757-5330-53742-A.SDR IPXA2574669Seat Track · damagedINSPECTION TYPE: C, CARGO TRACK BS 440-680 LBL 45 DAMAGED. R & R AND REPAIRED MAIN CARGO SEAT TRACK BS 440-680, LBL 45 IAW EO B757-5310-39408-A.SDR IPXA2574677Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 231XHF DAMAGED AND REQUIRES FABRICATION. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574517Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 252XDF HAS DELAMINATION. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574707Floor Panel · damagedINSPECTION TYPE:C, MAIN CABIN FLOOR PANEL 252XTF DAMAGED AND REQUIRES STEP CUT. FABRICATED NEW FLOOR PANEL IAW EO 757-5320-9692-H.SDR IPXA2574633Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 251XGF HAS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574469Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 252XEF DELAMINATED FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574448Floorboard · delaminatedINSPECTION TYPE:C, FLOORBOARD 251XBF HAS DELAMINATION. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574631Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 242XBF IS DAMAGED. FABRICTED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574497Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 251XJF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574482Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD FOUND 251XAF DAMAGED. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574635Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 241XAF HAS DAMAGED INSERTS. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574634Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 251XPF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574632Floor Panel · damagedINSPECTION TYPE: C, MAIN CABIN FLOOR PANEL 251XMF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574449Floorboard · damagedINSPECTION TYPE: C, MAIN CABIN FLOORBOARD 241XJF HAS A DELAMINATED CORNER. REPLACED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574471Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 231XMF CORNER DELAMINATED. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574470Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 251XQF EDGE DAMAGE FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574468Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOORBOARD 252XRF DELAMINATED/MISSING INSERT. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574368Floorboard · damagedINSPECTION TYPE: C, AFT LT FLOORBOARD 251XNF INSERT PULLED FROM EDGE. FABRICATED A CARGO FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2574484Panel · damagedINSPECTION TYPE:C, LT TRIM PANEL HAS A DAMAGED FASTENER HOLE BOTH SIDES OF HOLE MARKED. FABRICATED TRIM PANEL IAW DWG 146N5439-3.SDR IPXA2574483Angle · corrodedINSPECTION TYPE:C-CK, RT ANGLE CORRODED IN SEVERAL AREAS STA 1717. FABRICATED ANGLE IAW DWG 146N5439-4.SDR IPXA2574393Floor Panel · damagedINSPECTION TYPE:C-CK, LAVATORY FLOOR PANEL 212XAF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574394Floor Panel · delaminatedINSPECTION TYPE:C, FLT DECK FLOOR PANEL 211XAF DELAMINATED AFT OTBD CORNER FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574252Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO FLOOR PANEL 232XTF HAS EDGE DAMAGE AT AFT OTBD CORNER. FABRICATED MAIN CARGO FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574251Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO COMPT FLOOR PANEL 231XSF HAS EDGE DAMAGE AT AFT OTBD CORNER. FABRICATED MAIN CARGO FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12574706Cargo Track · damagedINSPECTION TYPE:C-CK, MAIN CARGO BAY BS 879+3 RBL 24 CARGO TRACK GOUGED ON UPPER FLANGE. FABRICATED NEW SEAT TRACK IAW DWG 143N5481-4.SDR IPXA2574572Cargo Track · gougedINSPECTION TYPE: C, MAIN CARGO BAY SEAT TRACK GOUGED AT BS 879+3, RBL 45. REPLACED SEAT TRACK CROWN SECTION FROM BS 879-900, RBL 45 IAW DWG 143N, 5481 AND SRM 51-40-02.SDR IPXA12574268Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 232XXF HAS EDGE DAMAGED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2574601Skin · bulgedINSPECTION TYPE: C, EXTERNAL SKIN DENT BULGING AT BS 1675, STR 17R. REMOVED DAMAGED SKIN AND APPLIED SKIN DOUBLER IAW EA 120885.SDR IPXA11566579Coupling · leakingC HYD QTY DECREASED TO ZERO AND SYS PRESS LIGHT ILLUMINATED. EICAS MESSAGE: C HYD SYS PRESS DISPLAYED. FOUND NR 2 ACCUMULATOR LEAKING FROM UNION TO BOSS AREA OF PUMP. R & R NR 2 ACMP IAW MM REF 29-11-02-4. OPS & LEAK CHECK IAW MM 29-11-00, PG 201, WAS NORMALSDR IPXA1564005Window · out of adjustCAPTS WINDOW RELEASE HANDLE REQUIRES EXCESSIVE FORCE TO MOVE AFT (OPEN). ADJUSTED L2 WINDOW IAW MM 56-11-02-5. OPS CKS GOOD.SDR IPXA10562242Shear Web · corrodedINSPECTION TYPE:C2, CORROSION AND BARE METAL ON SHEAR WEB BS 558-660 LBL 45-65. REPAIR IAW ER 10-3672.SDR IPXA10562055Frame · dentedINSPECTION TYPE:C2, FRAME DENTED BS1500, STR 25-26 RT. REPAIRED IAW SRM 53-00-07-2R5.SDR IPXA10562054Frame · dentedINSPECTION TYPE:C2, FRAME DENTED BS 1480, STR 23-24 LT. REPAIRED IAW SRM53-00-07-2R5.SDR IPXA10562053Frame · dentedINSPECTION TYPE:C2, FRAME DENTED BS 1500 STR 23-24 LT REPAIRED IAW SRM 53-00-02-1A, 53-00-07-2R5.SDR IPXA10562052Frame · dentedINSPECTION TYPE:C2, FRAME DENTED BS 1340 STR 25-26 LT. REPAIRED IAW SRM53-00-07-2R5.SDR IPXA10562644Floorboard · damagedINSPECTION TYPE:C2 MAIN CARGO FLOOR BOARD AT BS 480 TO 560, BL0 TO RBL25 IS BROKEN AND MISSING INSERTS. REPLACED IAW EO B757-5320-9692.SDR IPXA10562063Floorboard · damagedINSPECTION TYPE:C2, FLOORBOARD AT BS 480 TO 560, BL 0 TO RBL 25 IS BROKEN REPLACED IAW EO B757-5320-4692.SDR IPXA10562252Seat Track · corrodedINSPECTION TYPE:C2, REPLACED SEAT TRACK FROM STA 440 TO 680 LBL 45, REPLACED IAW ER NR 10-3927, DATED 26AUG10.SDR IPXA10562122Floor Panel · corrodedINSPECTION TYPE:C2, FOR RCD ONLY: AFT DECK PLATE CORROSION AT BS 1699, LBL 20 - 23. REPAIRED IAW ATS ER 10-3731, DATED 8-18-10.SDR IPXA10562121Floor Panel · corrodedINSPECTION TYPE:C2, FOR RCD ONLY: AFT DECK PLATE CORROSION AT BS 1715, RBL 2-9. REPAIRED IAW ATS ER10-3731, DATED 8-18-10.SDR IPXA10562166Support · gougedINSPECTION TYPE:C2, ACB FLOOR TO SIDEWALL SUPPORT GOUGED OR UPPER SURFACE AT BS 1598, WL 156, RBL 19. REMOVED, FABRICATED, INSTALLED REPLACEMENT SEGMENT.SDR IPXA10562151Floorboard · damagedINSPECTION TYPE:C2 FLOORBOARD AT STA 333 TO 440, LBL 45-60. REQUIRES STEP CUT FOR SHEAR WEB REPAIR. FABRICATED REPLACEMENT FLOORBOARD IAW B757-5320-9692-G.SDR IPXA10562150Floorboard · damagedINSPECTION TYPE:C2 FLOORBOARD AT STA 333-440, LBL 25-45 REQUIRES A STEP CUT FOR SHEAR WEB REPAIR. APPLIED STEP CUT TO FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA10562247Intercostal · puncturedINSPECTION TYPE:C2, FOUND PUNCTURE IN INTERCOSTAL, BS 502, LBL 45, WL 206. REPLACED IAW ATS ER 10-4153.SDR IPXA10562246Intercostal · puncturedINSPECTION TYPE:C2, FOUND PUNCTURE INTERCOSTAL, BS 457, WL 206. REPLACED INTERCOSTAL IAW ER 10-4153 & DWG 140N2054.SDR IPXA10562244Intercostal · puncturedINSPECTION TYPE:C2, FOUND PUNCTURE IN INTERCOSTAL, BS 502, LBL 45, WL 206. REPLACED IAW ATS ER 10-4153.SDR IPXA10561867Floor Panel · delaminatedINSPECTION TYPE:C2, FLOOR PANEL AT STA 333 TO 440, LBL 45 TO LBL 60, HAS 2EA INSERTS MISSING AND IS DELAMINATED. FABRICATED REPLACEMENT FLOOR PANEL IAW UPS EO B757-5320-9692-G AND EO B757-5100-33281-B.
Back to N429UP