N430UA
Service difficulty reports · 116
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N430UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N430UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026101220279Display · faultedCAPTAINS PFD FAILED AT ROTATION SCREEN CAME ALIVE UPONLANDING. REMOVED AND REPLACED CAPT PFD AND RELAY 20WT1. OPS CHECK NORMAL IAW AMM 31-63-22-400-001-A.SDR CALA2026060516847Fuel Cap · missingFUEL CAP MISSING. NO LEAKS AT COUPLING AND INSTALLED PLACARD 911288SDR CALA2025082708178Warning Light · false activationFWD CARGO DOOR ECAM ON LANDING ROLLOUT PLACING BACK ON MEL BECAUSE OF EXTENSIVE HISTORY. REQUESTING MEL 5270J NOC MEL 5270J APPROVED PLA APPLIED. DDP C/W. *DM* AWM 31-54-46 INSPECT WIRES TO PROX SWITCH FOR CONDITION. CHECK WIRES WITHIN HARNESS 4613VB. ALSO SEESDR CALA2025081507828Sensor · out of adjustREPEAT LEVEL 2 CHRONIC FWD CARGO DOOR ECAM, WIRE HARNESS, 28WV, AND 30WV SENSORS HAVE BEEN REPLACED, SENSOR GAPS HAVE BEEN CHECKED SEVERAL TIMES, PROBLEM SEEMS TO HAPPEN A LOT ON TAXI WHEN A/C IS SHAKING, REF TSM 52-31-00-810-801-A. CLOSE AND LATCH THE DOOR ANSDR CALA2025080607366Wire Harness · faultedLEVEL 2 CHRONIC FWD CARGO DOOR DISPLAYED ON UPPER ECAM. AVIATAR IS NOT REPORTING ANY CORRELATED CMS FAILURE MESSAGES. SENSORS 28 WV AND 30WV HAVE BEEN REPLACED & ADJUSTED MULTIPLE TIMES. INSPECTED FWD CARGO DOOR HANDLE LATCH ASSY & HOOK, NO DEFECTS FOUND, SDR CALA2025071806709Seal · brokenFOUND ENGINE NR 1 FWD PYLON TO NACELLE PROFILES PANEL BROKEN. INSTALLED E#1 FWD PYLON TO NACELLE PROFILES PANEL REFERENCE AMM TASK 54-57-22-400-003-A.SDR CALA2025071606633Proximity Switch · faultedDOOR FWD CARGO ECAM 2 TIMES ON GND DURING BRAKING. PRESS NORMAL IN FLT. PLACED FWD CARGO INDICATION ON MEL 5270U. DOOR WAS VISUALLY CHECKED & CONFIRMED CLOSED & LATCHED FOR DEPARTURE. PROXIMITY SWITCH WAS REPLACED. INSPECT WIRES TO PROXIMITY SWITCH FOR COSDR CALA2025062605880Proximity Sensor · faultedDOOR FWD CARGO ECAM ON LANDING ROLLOUT - WENT AWAY AT 80 KTS R/R FWD CARGO DOOR PROXIMITY SENSOR IAW IPC 52-71-02. ALL INDICATION OP CHECK NORMAL ON ECAM WHEN OPENING AND CLOSING DOORSDR CALA2024061700010Module · faultedERRONEOUS OVERSPEEDWARNING DURING FLAPRETRACTIONVMO WARNING AFTE R THAT PER CREW VERBAL WAS BELOW OVERSPEED BY 6 KNOTS ON CLIMB AND DECENT, GROUND TEST RESULTS, FOUND ADM 19FP3 DISCONNECTED FROM PITOT LINE.,SDR CALA2024061701821Connector · disconnectedERRONEOUS OVERSPEED WARNING DURING FLAP RETRACTION VMO WARNING AFTE R THAT PER CREW VERBAL WAS BELOW OVERSPEED BY 6 KNOTS ON CLIMB AND FOUND ADM 19FP3 DISCONNECTED FROM PITOT LINE.SDR CALA2024061301789Bracket · shearedLT MLG FWD DOOR FITTING HAS 2EA SHEARED FASTNER. REMOVED AND REPLACED LH MLG FWD DOOR HINGE FITTING IAW REPAIR IN STRUCTION R 533 70500 F.SDR CALA2024031800771Proximity Sensor · intermittentL/G/SHOCK ABSORBERFAULT ECAM. LOSS OFAUTO PILOT/THRUST. POST FLIGHT REPORT FAULTS N LG EXT PROX SENSOR 25GA AND N LG SHOCK ABSORBER 2526GM. VISUAL INSPECTION OF 25GA CHECKS NORMAL. REF TSM 32-31-00-810-815-A AND TSM 32-31-00-810-868-A. PIC INCLUDED OF POST FLTSDR CALA2023102703205Door · warning messageAFT CARGO DISPLAYED ON UPPER ECAM SCREEN. - DOOR AFT CARGO DOOR SHOWED OPEN DURING FLIGHT. PERFORMED OPERATIONAL TEST OF AFT CARGO DOOR REF AMM 52-32-00-710-001-A. FOUND 2 SCREWS WHERE THE DOOR HANDLE ATTACHES TO THE LEVER ASSY VERY LOOSE CAUSING THE DOOR HANDSDR CALA2023080202413Slide · unwanted deployDOOR 1L SLIDE DEPLOYED AT GATE. ITEM LOCKED FOR MAINT FERRY TO ORD, UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. UNLOCKING TO CLEAR ACCOMPLISHED INSTALLATION INSPECTION OF 1L ESCAPE SLIDE IAW AMM 25-62-44 OPS CHESDR CALA2023071702271Window · crackedCRACKED/FAILED CAPTSLIDING COCKPIT WINDOW UPDATED MAA CODE FIX USING VENDOR MAA SCREEN UPDATED MAA CODE FIX USING VENDOR MAA SCREEN UPDATED MAA CODE EFS USING VENDOR MAA SCREEN UPDATED MAA CODE EFS USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING SDR CALA2023022700562None · noneEXTERNAL PWR RECPTACLE NOT ACCEPTING GND PWR DISCONNECTED EXTERNAL POWER RECEPTACLE AND INSPECTED FOR DAMAGE. RECONNECTED POWER RECEPTACLE TO ACFT, ACFT SHOWS POWER AVAILABLE AND OPERATES NORMAL AT THIS TIME. REF. AMM 24-41-00SDR CALA2023020100304Power Supply · noneRIGHT EMERGENCY OVERWING LIGHT POWER SUPPLY IS FAULTING. REPLACED RIGHT EMERGENCY POWER SUPPLY BOX PER AMM33-51-38, OPS CHECKED GOOD PARTS USED: 1103737,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1103737 SN OFF 9557 POWER SUPPLY, C OFF 31-3350-9-9001 SDR CALA2022122103452Controller · faultedFCTL SPLR FAULT AT CRZ SPLRS APPEAR FLUSH, INOP SYS SPLR 5 INSPECTED WIRING AT NR 5 SPOILER ACTUATORS, NO DAMAGE FOUND. VERIFIED INSTALLATION OF #5 SPOILER , SAFETY AND SECURITY OF COMPONENT UP TO 4 C 9 IAW GMM 09-25-05. ACCOMPLISHED CONTINUITY CHECKS AND MEGGSDR CALA2022071301718Fitting · noneREF LP:8983603 R/MLG KEEL BEAM AFT REINFORCEMENT FITTING WEB HOLES R75 ELONGATE D AND R76 DOUBLE DRILLED. BEAM HOLES. PLANNING TO CONTACT ENGINEERING AFTER 22MAY2023 BUT INSTRUCTIONS" BEFORE 01JUN2023 FOR THE ECRA 5330-06960 PART 3 PERMANENT REPAIR INTERIM REPSDR CALA2022071101705Frame · crackedL/H FR35 STGR 28-31 HOLE #2 HAS A CRACK INDICATION IN FRAME LAYE R AT THE 1 O''CLOCK POSITION ON HAECO LCQ REF 9294155/20155 AD RE LATED TASK AD 2016-14-03. NR GENERATED BY V061632 FOLLOWS "ACCOMPLISH A PERMANENT REPAIR ON THE HOLES AT FR35 OR BEFORE 06-JAN-23SDR CALA2022071101704None · crackedFR36 PRESSURE DECK BETWEEN LH765 & 1523, HOLES 2,4,5,6,9,10,11,1 2,13,14,15,16 HAVE CRACK INDICATIONS IN PRESSURE DECK LAYER ON H AECO LCQ REF 9294636/30636 AD RELATED SUPPORT TASK. NR GENERATED BY V892444 WORK RECORDED & DIPS CARRIED ON LOG PAGES 9026593 AND SDR CALA2022071101703Frame · crackedRH FR35 STR30 HOLE #2 HAS A CRACK INDICATION IN FRAME LAYER AT THE 4 O''CLOCK POSITION. AS FOLLOWS "ACCOMPLISH PERMANENT REPAIR AT RH FR35 STR30 HOLE #2 OR BEFORE 06JAN2023." INSP:LC19 PER PART 3 OF THE LATEST OF THE REVISION OF ECRA 5331-02922 ON PERFORMED INSDR CALA2022071101702Panel · crackedFR36 PRESSURE DECK BETWEEN LH 765 AND RH, HOLES 2,4,10,11,13,15, 16,19,20,21,24,29,31,32,40 HAVE CRACK IN PRESSURE DECK LAYER GEN ERATED BY V892444 AT HAECO LCQ PER NR 9294638 (30638) AD RELATED SUPPORT TASK INTERIM REPAIR PERFORMED ON FR36 PRESSURE DECK BETWESDR CALA2022071101701Pressure Deck · crackedFR36 PRESSURE DECK BETWEEN RH 765 AND RH 1523, HOLES 5,10,12,13, 14,15,16,17,18 HAVE CRACK INDICATIONS IN PRESSURE DECK LAYER AD RELATED SUPPORT TASK, GENERATED BY V892444 AT HAECO LCQ PER NR 9 294640 (30640) 1-7 FOR AFFECTED HOLE LOCATIONS. PER PART 1 STEP.2SDR CALA2022070801687Frame · crackedLH FR 68, STGR 22 WEB, HORIZONTAL FLANGE RADIUS AFT SIDE OF FRAM E, HAS A CRACK INDICATION AT LOWER SURFACE 1.25" LONG, FROM BELO W RADIUS INTO INBD CAP, TO OTBD DIRECTION. GENERATED BY V061671 ON HAECO LCQ NR 9294408/30408 CCOMPLISH INITIAL INSPECTIONS ON FRASDR CALA2022070801686Fitting · damagedLH KEEL BEAM & MLG DOOR FITTING HAS DISCREPANT HOLES. LOCATIONS & DETAILS. PER PART 1.2 OF ECRA "ACCOMPLISH A PART 3 OF LATEST REVISION OF ECRA 5330-06961 ON OR BEFORE PERMANENT REPAIR OF THE LH MLG DOOR FITTING KEEL BEAM HOLES PER 24-JUN-2023." PERFORMED INTSDR CALA2022070801685Frame · crackedRH FR 68, STGR 22 WEB, HORIZONTAL FLANGE RADIUS AFT SIDE OF FRAME, HAS A CRACK INDICATION AT LOWER SURFACE .535" LONG, STATING FROM INBD CAP, TO OTBD DIRECTION. GENERATED BY V061671 ON HAECO L CQ NR 9294409/30409 TION ON FRAME REPAIR PART FILLET RADII AND FASTSDR CALA2022062901601Intercostal · crackedL/H Y+1292 FR 11-8" HAS CRACKED WEB. GENERATED AT HAECO LCQ PER NR 9294798 (30798) BY V061673. {SUPPORT TASK} REPAIRED CRACKED WEB AT L/H Y+1292 FR 11-8 IAW A320 SRM 53-11-14 -300-005. PERFORMED BY V929087 INSP BY V919150.SDR CALA2022062801598Angle · crackedR/H AFT EMERGENCY EXIT DOOR FORWARD SUPPORT ANGLE HAS CRACK. AT HAECO LCQ NON-ROUTINE CARD 9294699/30699 GENERATED BY V061771. D OT : RR131 REMOVED AND REPLACED SUPPORT ANGLE ON RIGHT HAND AFT EXIT DOOR I AW A320 SRM 51-42-11 & SRM 51-72-11 PER MECH V052030 INSDR CALA2022061701520Angle · crackedSUPPORT TASK: L/H FORWARD EMERGENCY EXIT DOOR FORWARD SUPPORT AN GLE HAS CRACK. DOT: RR128. AT HAECO LCQ NON-ROUTINE 9294696/3069 6 GENERATED BY V061771. REMOVED AND REPLACED SUPPORT ANGLE ON LH EMERGENCY EXIT DOOR IAW A320 SRM 51-42-11 & 51-72-11. REMOVED DOTSDR CALA2022060801459Stringer Splice · corrodedFWD CARGO STRINGER SPLICE AT FR33/34 STR39L HAS CORROSION. DOT: 20 GENERATED BY N078570 AT HAECO LCQ PER NR 9294617 (30617) SUPP ORT TASK REMOVED AND REPLACED FWD CARGO STRINGER SPLICE-COUPLING AT STRG 39L BETWEEN FR33 AND FR34 IAW A320 SRM 51-72-11-911-001. NSDR CALA2022060101410Intercostal · crackedRH AFT EMERGENCY EXIT DOOR AFT SUPPORT ANGLE HAS CRACK SUPPORT GENERATED BY V061771 AT HAECO LCQ PER NR 9294700 REMOVED AND REPLACED SUPPORT ANGLE ON AFT EXIT DOOR IAW A320 SRM 51-42-11 & 51-72-11. PERFORMED BY V052030 INSP BY V892285SDR CALA2022060101409Support Angle · crackedLH FWD EMERGENCY EXIT DOOR AFT SUPPORT ANGLE HAS CRACK SUPPORT T ASK GENERATED BY V061771 AT HAECO LCQ PER NR 9294697/30697 REMOVED AND REPLACED SUPPORT ANGLE ON EXIT DOOR LH AFT IAW A320 SRM 51-42-11 & SRM 51-72-11 PERFORMED BY V052030 INSP BY V892285SDR CALA2022053001379Fitting · corrodedR2 DOOR SILL FWD CORNER FITTING HAS CORROSION SPOTS DOT:M072 (A3 NB-05-3-6059) GENERATED BY V919150 AT HAECO LCQ PER NR 9294532 ( 30532) REMOVED AND REPLACED FWD CORNER 19HING ON R2 DOOR SILL IAW A320 SRM 51-42-11 AND SRM 51-72-11 PERFORMED BY V052030 INSP BY SDR CALA2022052501330Stringer · corrodedEVIDENCE OF CORROSION AFT CARGO STR 43L FR64-65 AT HAECO LCQ NON ROUTINE 9294478/30478 GENERATED BY V052040 SPEC (A3NB-05-3-6026) REMOVED AND REPLACED AFT CARGO STR 43L FR64-65 IAW A320 SRM 53-4 BY V892285 1-13-283-002. INSTALLED 25 EA FASTENERS AND INSTALLED SDR CALA2017041400992Battery · inoperativeFLT DECK EMER FLASHLIGHT NOT BLINKING. REPLACED BATTERY IN EMER FLASHLIGHT @ FLT DECK AND APPLIED NEW SEAL. OPS GOOD.SDR CALA2017041400991Flashlight · unsecureAFT CABIN FLASHLIGHT AFT CABIN WAS PULLED OUT OF HOLDER. INDICATOR LIGHT NOT FLASHING REPLACED BATTERY AT AFT OTBD EMER FLASHLIGHT AND RESEALED. OPS GOOD.SDR CALA2015080794181Battery · failedIAW A CHECK J C 4-2025 ITEM 27, CABIN EMER LIGHTING CHECK FAILS BATTERY AFT LT. REPLACED BATTERY, TEST RESPONSE PASSED.SDR CALA2014060291189Proximity Switch · dirtyDOOR 1L NOT SHOWING ARMED. VERIFIED DOOR CLOSED & ARMED PRIOR TO DEPARTURE. CLEANED PROXIMITY SWITCH 4WN1 SYS CHECK NORMAL.SDR CALA2013123094002Warning System · activatedHYD RAT FAULT INDICATED ON UPPER ECAM SCREEN. RAT OUT MESSAGE INDICATED ALSO. DISCONNECTED ELECTRICAL CONNECTOR 2454GE-C.SDR CALA2013121293639Control Unit · inoperativeSMOKE DETECTOR CONTROL SYSTEM INOPERATIVE. REPLACED SDCU IAW AMM 26-17-34. OPERATIONS TESTED OKAY.SDR CALA2013092791507Oxygen Mask · unsecure20 ABC OXY MASKS HANGING. RESTOWED MASKS ROW 20ABC IAW MX TIP 35-003. REQUIRES MAN MASK RELEASE OPERATIONS CHECKED IAW AMM 35-2 3-00-710-001 WITHIN 3 DAYS. ACCOMPLISHED ACPD OPERATIONAL TEST OXY GEN MASK IAW AMM 35-23-00 OK.SDR CALA2013092391372Oxygen Mask · unsecureO2 MASK DROPPED AT 29 DEF. SECURED O2 MASK AT 29 DEF. REPACKED & ENSURE LATCH FULL ENGAGED IAW MT35-003.SDR CALA2013081990525Engine · making metalAPU AUTO SHUTDOWN WITH SMOKE REPORTED AND VIBRATION FELT IN COCKPIT. REMOVED APU MAG CHIP DECTECTORS AND FOUND A LARGE DEPOSIT OF METAL FLAKES. SUGGEST APU CHANGE. METAL FLAKES BEYOND LIMITS IAW 49-91-42. APU PN MR49206.SDR UALA2013053003767Cap · missingPUSH BUTTON CAP FOR CARGO SMOKE TEST IS MISSING. JUST POST FOR CAP USEABLE. REPLACED CARGO SMOKE TEST BUTTON CAP.SDR UALA2013052303566Control Panel · failedNO CAPTAIN`S SIDE RADAR DISPLAY, FIRST OFFICER`S SIDE OK. REPLACED WEATHER TRANSCIEVER IAW MM. ALSO REPLACED WEATHER CONTROL PANEL. FOUND LOOSE PARTS INSIDE CONTROL PANEL. NEW CONTROL PANEL CHECKED NORMAL AT GATE. WEATHER PAINTS ON BOTH DISPLAYS.SDR UALA2013040802301Valve · failedCABIN TEMP, ALL ZONES EXTREMELY ERRATIC AND IMPOSSIBLE TO CONTROL. ROAMS TO EXTREME. REPLACED HOT AIR PRESSURE REGULATING VALVE. OPS CHECKED GOOD.SDR UALA2013032802000Liner · damagedPIECE OF HONEYCOMB RUB STRIP MISSING ON NR 2 ENGINE AT 6:00 AND 6:30 POSITIONS. REPAIRED FAN CASE ATTRITION LINER AT 6:00 AND 6:30 POSITIONS PER MT 72-017 REV E.SDR UALA2013031901662Liner · damagedNR 2 ENGINE A QUARTER SIZE PIECE OF ATTRITION LINER MATERIAL MISSING. REPAIRED ATTRITION LINER REPAIR.SDR UALA2013030501308Controller · faultyCREW REFUSAL. MUST FIX DF0451 PRIOR TO DEPARTURE. TOILET VACUUM MOTOR STARTED RUNNING CONTINUOUSLY AFTER TAKEOFF. REMOVED AND REPLACED LAV BLOWER MOTOR CONTROLLER.
Back to N430UA