N433UA
Service difficulty reports · 200
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N433UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N433UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009122804012Rib · damagedDUE TO DAMAGE TO RT WING LOWER WINGLET, NECESSARY TO PERFORM INSP. AFTER REMOVING WINGLET FOUND 4 POPPED RIVETS, DAMAGED RIB, 2 LOOSE RIVETS IN BOTTOM SIDE AND WRINKLED SKIN TO NEXT INBD RIB. DAMAGE WAS IS THE WING TIP ASSY. REPLACED WING TIP ASSY. OPS CHESDR UALA2009090802800Computer · faultedELAC 2 PITCH FAULT, FLIGHT DIVERTED. SWAPPED ELAC 1 AND 2 FAULT FOLLOWED BOX REPLACED ELAC2. ACP OPS TEST OF ELAC2 AND CAT III MM 22-97-00 PASSED CAT III LAND TEST.SDR UALA2009080302326Light · faultyEMERGENCY LIGHT TEST FAILED. REPLACED SLIDE. ACCOMPLISHED RII INSPECTION OF SLIDE REPLACEMENT.SDR UALA2009060201588Slide · faultyEMERGENCY LIGHTS FAILED TEST 2 TIMES. 'EXT LOAD AFT L' FAULT MSG ON CIDS. T/S FOUND L AFT SLIDE BAD. REPLACED SLIDE. INSPECTED SLIDE INSTALLATION. CONFIRMED CIDS TEST.SDR 2008UALA06402Slide · faultyEMERGENCY LIGHTS FAILS TEST. FAULTS EXT LOAD AFT L. REPLACED DOOR 2L SLIDE.SDR 2008UALA06074Slide · faultyCABIN EMERGENCY LIGHT TEST EXT LOADS AFT L FAILED 3SV CHECK. REPLACED DOOR 2L EMERGENCY ESCAPE SLIDE. EMERGENCY LIGHT CHECK GOOD.SDR 2008UALA03922Slide · faultyTEST OF EMERGENCY LIGHT SYSTEM SHOWS AFT EXTERNAL LOAD FAULT. *S/D* INTERNAL SHORT/HIGH RESISTANCE IN SLIDE 2L. REMOVED AND REPLACED 2R DOOR SLIDE, OPS TEST ARE NORMAL.SDR 2008UALA03921Skin · damagedRT WING O/B FLAP HAS A REPAIR OF 8 INCHES BY 15 INCHES ON LOWER TRAILING EDGE. THE TRAILING EDGE OF REPAIR IS SEPARATING FROM FLAP. *S/D* REPAIRED FLAP.SDR 2008UALA03620Wire · shortedTHREE SERVICE EMERGENCY LIGHT TEST FAILS. FAULT MSG EXT LOADS AFT L DISPLAYED. *S/D* INTERNAL SHORT IN DOOR SLIDE 2L. REPLACED 2L DOOR SLIDE.SDR 2008UALA02572Window · faultyF/O SLIDING WINDOW HAS BUBBLES FORMING ON ENTIRE WINDOW. HOT TO TOUCH. REPLACED F/O SLIDING WINDOW.SDR 2008UALA02412Contactor · brokenEMERGENCY ELECTRICAL GENERATING SYSTEM FAILS OPS TEST. FOUND CONTACTOR RELAY BASE BROKEN. REPLACED TRANSFORMER AND CONTACTOR BASE, ALL TESTS ARE NORMAL.SDR 2008UALA02323Slide · shortedEMERGENCY LIGHT TEST RESULT SHOW 'EXT LOAD AFT L' AT FAULT. FOUND RT AFT SLIDE SHORTED INTERNALLY. REPLACED RH AFT SLIDE AND RETESTED EMER LIGHTS SYSTEM OK
SDR 2008UALA02322Power Supply · faultyEMERGENCY LIGHT POWER SUPPLY 13WL SELF-TEST FUNCTION INOP. FOUND EPSU FAILED. REPLACED POWER SUPPLY, OPS CHECKED GOOD.SDR 2008UALA01558Girt Bar · faultyDOOR 2R ARMED INDICATOR BAR MISSING. REPLACED GIRT BAR. REPLACED GIRT BAR.SDR 2008UALA00405Slide · shortedTHE "EXT LOAD AFT LEFT" DISPLAYED DURING EMERGENCY LIGHT TEST. ELECTRICAL SHORT IN AFT SLIDE (RT). REPLACED AFT RT SLIDE. TESTED, PERFORMED NORMALLY. NO REPEATS.SDR 2007UALA04971Connector · dirtyEMERGENCY LTS TEST FAILS WITH `AFT L EXT LTS` FAILURE MSG. FOUND DIRTY CONNECTION INSIDE SLIDE RAFT. REMOVED SLIDE AND CLEANED CONNECTOR- ALL OPS CHECK OK. NO REPEATS.SDR 2007UALA04158Slide · faultyCIDS TEST FAULT "EXT LOADS AFT L". REPLACED SLIDE ASSY. NO REPEATS.SDR 2007UALA03741Oxygen Mask · leakingTHE 2ND OB'S OXYGEN HARNESS FAILS TO INFLATE (IS LEAKING).SDR 2007UALA02171Elt · faultyFWD ELT MAKING A BUZZING NOISE. REPLACED ELT.SDR 2007UALA02004Gauge · leakingDOOR 2L SLIDE PRESSURE READING LOW. [06-22-07] BAD GAUGE GREEN TEMP BAR INOPERATIVE, ALSO HAD A SMALL LEAK AROUND GAUGE THREADS. REPLACED GAUGE, RETIGHTENED WITH THREAD TAPE, REFILLED AND WATER TESTED FOR 15 MIN, NO LEAK FOUND. REPLACED SLIDE.SDR 2007UALA01630Flap System · malfunctionedCREW REPORTS THAT ON APPROACH FLAPS LOCKED OUT AT 1 UNIT, UNABLE TO RESET. AMBER ALERT DECLARED. LANDED WITH LEADING EDGE DEVICES UP AND FLAPS AT 1 DEGREE.SDR 2007UALA01484Stringer · corrodedSTRINGER 43 LEFT HAS CORROSION FRAME 57 AND 58. MAJOR REPAIR ACCOMPLISHED: INSTALLED ANGLE DOUBLER REPAIR.SDR 2007UALA01415Seat Track · gougedCABIN OUTBOARD RIGHT SEAT TRACK HAS GOUGED LUG FWD ON FRAME 47. MAJOR REPAIR ACCOMPLISHED: REPLACED FLOORBEAM.SDR 2007UALA01380Sill · corrodedL2 DOOR SILL HAS CORROSION AT AFT SIDE NEAR FRAME 68. MAJOR REPAIR ACCOMPLISHED: INSTALLED ANGLE REPAIR.SDR 2007UALA01255Wire Harness · disconnectedSEAT 8C EEL LIGHT INOPERATIVE. FOUND WIRE HARNESS CONNECTOR UNDER SEAT ASSY TO HAVE WIRE PIN PULLED FROM CONNECTOR. THESE WIRE HARNESSES ARE EXPOSED AND CAN BE DAMAGED BY PASSENGER CARRY ON BAGGAGE UNDER SEATS.SDR 2007UALA01254Light · missingBOTH AFT DOOR LWR EMERGENCY EXIT LIGHT HAVE 1EA LAMP INOP. REPLACED MISSING LAMPS FROM EXIT SIGNS.SDR 2007UALA00674Light · no testEMERGENCY LIGHT TEST FAILED -EXT LOADS AFT L- NO GREEN SYS OK LIGHT CIDS RESET, NO HELP. [SUP 05-24-07] FAULT TRACED TO A FAULTY SLIDE PACK AT DOOR 2L. OVERHAUL OF THE SLIDE PACK FOUND THE GREEN SYSTEM LIGHTS TO BE DAMAGED.SDR 2006UALA02298Slide · faultyTEST OF EMERGENCY LIGHTS FAILED WITH -EXT LOADS AFT L-. REPLACED AFT RIGHT SLIDE.SDR 2006UALA01457Battery · dischargedFOUND CABIN EMERGENCY LIGHTS TEST FAILED PER NR 3 CHECK FORM. REPLACED BATTERY PACK AT 10WL.SDR 2006UALA01450Light · inoperativeEMERGENCY LIGHTS FAIL 3SVC CHECK AFT LOAD. FOUND RIGHT AFT SLIDE LIGHTS BAD. REPLACED DOOR 2R SLIDE. TEST PASSED.SDR 2006UALA01442A/C Pack · malfunctionedEMERGENCY DECLARED DUE TO CABIN DEPRESSURIZATION. REPLACED RT PACK FLOW CONTROL VALVE. OPS CHECKED OK. REPLACED APU COMPRESSOR DISCHARGE SENSOR [4951546], AND SPEED SENSOR [4950009]. OPS CHECKED GOOD. RAN BOTH PACKS AND MOTORED ENGINE, HAD GOOD DUCT PRESSSDR 2006UALA00305Slide · no testAFTER CABIN EMERGENCY LIGHTS CHECK PER 3 SERVICE, MESSAGE -EXT LOADS AFT L- APPEARED ON CIDS CONTROL PANEL. ALTHOUGH THE EMERGENCY LIGHT TEST WAS CODED UNDER ATA-33, THE FAILURE OF THE TEST WAS DUE TO THE 2L (MR25614) SLIDE ASSY LIGHT SYSTEM. THE DEFECTIVE 2SDR 2005UALA00942Slide · warning lightDURING CABIN EMERGENCY LIGHTS CHECK, FOUND EXT LOAD AFT LEFT ERROR MSG. REPLACED DOOR 2R SLIDE.SDR 2005UALA00591Hose · brokenHOSE FOUND BROKEN BY ASPIRATOR. HOSE WAS FOUND BROKEN AT END NEAR ASPIRATOR CONNECTION DURING MAINTENANCE OF THE SLIDE IN THE SHOP. PROBABLE CAUSES COULD BE MISHANDLING DURING TRANSPORTATION OR THAT THE ROUTING OF THE HOSE DURING THE PREVIOUS SLIDE PACKING SDR 2005UALA00589Hose · brokenHOSE FOUND BROKEN DURING THE PACKING PROCEDURE. HOSE WAS FOUND BROKEN AT END NEAR ASPIRATOR CONNECTION DURING MAINTENANCE OF THE SLIDE IN THE SHOP. PROBABLE CAUSES COULD BE MISHANDLING DURING TRANSPORTATION OR THAT THE ROUTING OF THE HOSE DURING THE PREVIOUSDR 2005UALA00375Light · malfunctionedEMERGENCY LIGHTS FAILING TEST IN AFT CABIN. AFTER SYSTEM RESET SYSTEM TESTED OK .SDR 2005UALA00306Actuator · failedNUMBER 1 ENGINE SHUT DOWN DUE TO ECAM WARNING FOR COMPRESSOR VANE, STALL AND EGT OVER LIMIT. REPLACED VSV ACTUATOR AND ACCOMPLISHED POWER ASSURANCE TEST. HISTORY SHOWED CLASS 2 FAULT MESSAGE ON VSV ACTUATOR FUNCTIONING ON ONE CHANNEL. A SUBSEQUENT STALL WASSDR 04UALA01181Slide · unserviceableDURING OVERHAUL OF DOOR TWO LEFT SLIDE THE MOORING LINE WAS FOUND TO BE PACKED IN BETWEEN GIRT HALVES. THE INFLATION CABLE WAS NOT RUN IN CABLE GUIDE BUT RUN THROUGH LACING GROMMET INSTEAD, THE SLIDE WAS FOLDED INSTEAD OF ROLLED AND WAS PACKED OVER BOTTLE ANSDR 2004UALA01181Bulb · burned out6 BULBS BURNED OUT. MOORING LINE NOT IN POCKET, PLACED IN BETWEEN GIRT HALVES. HOSE WAS TAPED OVER SWIVEL 6 INCES FROM MAT DOWN HOSE. INFLATION CABLE NOT RUN IN CABLE GUIDE AND RAN THROUGH LACING GROMMET, THEREFORE SLIDE WOULD NOT HAVE FIRED, WAS 10 INCHES SDR 2004UALA00892Transmitter · leakingFLIGHT EXPERIENCED GREEN HYDRAULIC SYSTEM LOSS OF QUANTITY. GREEN SYSTEM TRANSMITTER ON NR 1 ENGINE BROKEN AND LEAKED GREEN SYSTEM HYDRAULIC FLUID. REPLACED GREEN SYSTEM TRANSMITTER.SDR 2004UALA00548Rib · lightning strikeRIGHT ELEVATOR RIB 10 WAS DAMAGED BY LIGHTNING. REPLACED RIB AND INSTALLED BLIND FASTENERS.SDR 2004UALA00547Rib · lightning strikeLEFT ELEVATOR RIB 10 WAS DAMAGED BY LIGHTNING. REPLACED RIB AND INSTALLED BLIND FASTENERS.SDR 2002UALA01035Filter · collapsedABORTED TAKEOFF AT 90 KNOTS DUE TO VENT AVIONICS SYSTEM FAULT. THE AEVC SYSTEM FILTER WAS FOUND DIRTY AND COLLAPSED - REPLACED FILTER.SDR 2001UALA01195Slide · failedSLIDE FAILED AIR RETENTION TEST DURING OVERHAUL.SDR 98UAL900504Arm · failedNR 2 ENG HAD MULTIPLE COMPRESSOR STALLS, AUTO IGNITION CAME ON. COMPRESSOR STALL OCCURRED AT TOP OF DESCENT. *S/D* ENGINE DISASSEMBLY INVESTIGATION FOUND THE CAUSE WAS A FAILED HPC STAGE 3 LEVER ARM. THE MANUFACTURER WILL PUBLISH SERVICE BULLETIN 72-0334 IN SDR 98UAL900493Air Distribution · odorBURNING SMELL FOLLOWED BY A WHC2 FAULT MESSAGE ON UPPER ECAM. *S/D* ACCOMPLISHED PACK OPERATIONAL TEST. ALL CHECKS GOOD, NO DISCREPANCIES FOUND, NO BURNING SMELL. NO FAULT MESSAGES DISPLAYED AFTER TEST.SDR 98UAL900195Light · inoperativeEMERGENCY LIGHT SYSTEM TEST FAILED. REPLACED FORWARD LEFT EPS UNIT.SDR 97UAL900152Low Level Warn · activatedLOSS OF BLUE SYSTEM HYDRAULIC FLUID EN ROUTE TO ORD. LOW LEVEL DISPLAYED ON UPPER ECAM. SUPPLEMENTAL DATA UPDATE AFTER LANDING RAN ELECTRICAL PUMP AND CYCLED FLIGHT CONTROLS. NO FAULTS WERE FOUND AND NO REOCCURRING DISCREPANCIES ENCOUNTERED.SDR 96UAL900977Battery · dischargedEMERGENCY LIGHTS FAIL TEST. *S/D* REPLACED BATTERY IN POWER SUPPLY 10WL.SDR 96UAL900470Fuel Pump · failedAT CRUISE FL330, RECEIVED AN ECAM MESSAGE 'COMPRESSOR VANE'. SHORTLY AFTER ENGINE 2 BEGAN FLUCTUATING AND THEN SHUT ITSELF DOWN. *S/D* FOUND ALUMINUM CHIPS IN FUEL FILTER, IMPELLER STAGE AND HOUSING OF FUEL PUMP HAD EXTENSIVE DAMAGE CAUSED BY A BOLT IN FUE
Back to N433UA