N435UA
Service difficulty reports · 141
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N435UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N435UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012022001011Pan · crackedFWD LAV FLOOR IS CRACKED. GAINED ACCESS TO LAV FLOOR PAN, PER AMM. REPLACED FLOOR PAN AND INSTALLED LAV ASSEMBLY PER MM AND REINSTALLED CEILING BRACKETS PER MM.SDR UALA2012011600325Fastener · wrong partCOMPARTMENT 107 IN FWD GALLEY HAS WRONG SIZE QUARTER TURN. FOUND CORRECT QTR TURN INSTALLED.SDR UALA2011112206415Rivet · failedFAILED RIVET ON LEFT ENGINE EXHAUST NOZZLE 12 O'CLOCK POSITION REF MT 78-001 MISSING RIVETS ALLOWED, MUST BE REPAIRED. REPLACED WITHIN 50 HRS. OK TO CF PER THIS MAINT TRIP. REPLACED MISSING RIVET.SDR UALA2011110405996Wire · damagedGEN 2 FAULT DISPLAYED ON UPPER ECAM. NR 2 ENG IDG WILL NOT COME ONLINE UNTIL MANUALLY SELECTED, ALL PARAMETERS NORMAL AFTER SELECTION. RMV'D NR 2 ENG IDG. REMOVED MR24212-40978. BREAKERS T27 AND T25 PULLED AND COLLARED. RPLC'D IDG AGAIN, STILL NO HELP. FOSDR UALA2011102705813Handset · malfunctionedFWD FLIGHT ATTENDANT INTERCOM TRANSMITS OVER THE P/A WHEN TRYING TO TALK WITH THE CAPT. REPLACED FWD ATTENDANT HANDSET, TESTED OKAY.SDR UALA2011072103700Fuel Cell · leakingFUEL LEAKING THRU RT OTBD FLAP INBD TRACK SUPPORT FITTING. FOUND THE SOURCE OF LEAK INTERNALLY & EXTERNALLY. REMOVED OLD SEALANT FROM FASTENERS. REMOVED NUT. REPLACED WET WITH NEW WASHER. RESEALED ALL AREAS WITH A1-2 A ND B1-2 AT 0415 HRS. FOUND A SECONDSDR UALA2011060802821Panel · faultyOXYGEN PANEL OPENED AT SEATS 12 ABC, MEL 3521A COMPLIED WITH. SEATS CANNOT BE OCCUPIED. DROP CK REQUIRED PER AMM AFTER REPAIR OF O2 CONTAINER. THE AFFECTED SEATS ARE IN ROW 13ABC NOT 12ABC. SEATS AT ROW 13ABC ARE CORRECTLY BLOCKED OUT, AMM TASK SYS TEST. SDR UALA2011060302710Battery · faultyEMERGENCY LIGHTS TEST FAULTS EXT LOADS EMERGENCY L. REPLACED 11WL BATTERY AND RELAMPED LT OVER WING AFT SLIDE LIGHTS.SDR UALA2011020100538Battery · inoperativeF/A FLASHLIGHT AT 2L (OTBD) IS INOPERATIVE. REPLACED BATTERY FLASHES NORMAL.SDR UALA2011010700109Fcu · failedIN-FLIGHT FAULT WITH ALTITUDE SELECT. REPLACED FCU AND CABIN PRESSURE SWITCH - LND ELEV AUTO (20HL) PCN (110-4328). BOTH ITEMS CHECKED GOOD.SDR UALA2010082303087Rod End · out of limitsTAIL VIBRATION, RTFL. CLIMBING THRU FL310 .75M FELT MODERATE TAIL VIBRATION. SLOWED TO .7M VIBRATION WAS LESS BUT DIDN'T DISAPPEAR. INCREASED SPEED BACK TO .75M VIBRATION RETURNED. REDUCED SPEED TO 250 KIAS FOR RETURN TO DEPARTURE. VIBRATION VERIFIED BY CRSDR UALA2010070902451Floorbeam · corrodedCORROSION FOUND ON FLOORBEAMS FRAME 24 DURING FLOORBOARD REPLACEMENT. THREE (3) EA FLOORBEAMS EXTENSIVE CORROSION. EXFOLIATION CORROSION FOUND BETWEEN FRAME 21 AND FRAME 24 ON RT SIDE FLOOR RAIL Y-765 APPROX 4 INCHES LONG BY 1 INCH WIDE. CORROSION FOUND ON SDR UALA2010070702420Battery Pack · failedEMERGENCY LIGHT TEST FAILS FOR RIGHT OVERWING LIGHT BATTERY. REPLACED RT OVERWING EMERGENCY LIGHT BATTERY. EMERGENCY LIGHT TEST PASSED.SDR UALA2010062802280Smoke Detector · false activationAFT CARGO SMOKE DISPLAYED ON UPPER ECAM SCREEN. AGENT 1 DISCHARGED, AFT CARGO 'SMOKE' LIGHT ON OVERHEAD PANEL ALSO ILLUMINATED. PFR, LLR, AND PLR ALL SHOWED NO FAILURES. CFDS SDCU TEST-SMOKE LOOPS AFT LDCC-TESTED OK. LOOP A AND B OK. BOTTLE REPLACED.SDR UALA2009121603892Battery · no testEMERGENCY LIGHT SYS WILL NOT TEST. CODE - BATT EMER L-SHOWING. T/S TO BATTERY IN L EMER PSEU. REPLACED BATTERY.SDR UALA2009082402618Wire · damagedEMERGENCY PATH LIGHTING ON SEATS 1C, 7C, 21C & 26C INOP. REPLACED LAMPS AT SEATS 1C, 7C AND 26C. REPAIRED WIRE AT SEAT 21C.SDR 2008UALA05788Fire Loop · faultedFIRE LOOP A FAULT DISPLAYED ON UPPER ECAM SCREEN, ENG 2. FOUND FIRE DETECTOR UNIT FAULTY. REPLACED UNIT. TESTS OKAY.SDR 2008UALA04054Slide · lowDOOR 1L ESCAPE SLIDE PRESS IS NOT IN GREEN BAND.
SDR 2008UALA02635Battery · failedRT OVERWING EMERGENCY LIGHT BATTERY FAILED TEST. REPLACED BATTERY. TEST OK.SDR 2007UALA03739Anti-Ice System · arcedWINDOW 1L HAS REPORTED ARCING AND DAMAGE. WINDOW HEAT INOP.SDR 2007UALA02192Stringer · corrodedSTR 42R HAD CORROSION AND DRILL MARKS BETWEEN FR 26 AND 27. INSTALLED A SPLICE REPAIR.SDR 2007UALA02191Stringer · damagedSTR 42R BETWEEN FR 27 AND 28 HAD A DRILL MARK BLENDED OUT BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED: INSTALLED A REPAIR ANGLE.SDR 2007UALA02190Rivet · corrodedFWD PIT HAS NUMEROUS CORRODED FASTENERS FROM FRAME 24 THROUGH 35 BETWEEN STRINGER 38L AND 38R. REPLACED A TOTAL OF 1918 RIVETS.SDR 2007UALA02094Structure · corrodedFWD PIT HAS CLEAT WITH CORROSION AT FR33 AND STR 41R. MAJOR REPAIR ACCOMPLISHED: REPLACED CLEAT.SDR 2007UALA02028Skin · dentedLEFT FUSE SKIN IS DENTED AT FRAME 7, 6 INCHES ABOVE THE STRIPES. DENT IS OUT OF LIMITS FOR DISTANCE FROM FRAME AND IS LOCATED WITHIN THE RVSM AREA. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER REPAIR.SDR 2007UALA02003Frame · corrodedFWD PIT FRAME 32 HAS A CORRODED CLEAT AT STRINGER 41R. MAJOR REPAIR ACCOMPLISHED: REPLACED WITH NEW CLEAT.SDR 2007UALA00217Unknown · vibrationMODERATE TO SEVERE VIBRATIONS FELT IN AFT CABIN & FLT DECK FLOOR ON CLIMBOUT. VIBRATIONS SUBSIDED AT LEVEL OFF. CONDITIONS REAPPEARED ON SUBSEQUENT FLIGHT. ACCOMPLISHED ELEVATOR INTEGRITY CHECKS. ALL 4 SERVOS REQUIRED ADJUSTMENT TO .5 DEGREES NOSE UP. FRSDR 2007UALA00201Unknown · vibrationA/C VIBRATION FELT ON CLIMB-OUT 3 TIMES. CHECKED ELEVATOR FOR FREE PLAY, RIGHT SIDE HAD ENOUGH PLAY TO WARRANT REPLACEMENT OF YELLOW SERVO CONTROL. AFTER REPLACEMENT OF SERVO CONTROL PLAY WAS WITHIN STANDARDS. OPS CHECKED GOOD. ACCOMPLISHED INSTALLATION INSDR 2007UALA00136Cable · misroutedAFT RIGHT SLIDE ELECTRICAL CABLE WAS ROUTED THROUGH THE AFT END OF THE GIRT. ELECTRICAL CABLE INSTALLED CORRECTLY.SDR 2006UALA01539Warning System · activatedON TAXI OUT AIR ENG 1 BLEED FAULT UPPER ECAM. UPON RETURN TO GATE, ACCOMPLISHED FWC RESET, BLEED MESSAGE NO LONGER PRESENT. ACCOMPLISHED ENGINE RUN CONFIDENCE CHECK, NO BLEED MESSAGE PRESENT.SDR 2006UALA01443A/C Pack · failedDIVERTED FLIGHT DUE TO FAILURE OF BOTH PACKS.SDR 2006UALA00089Stop · out of adjustDOOR 2R NOISY AND ECAM SHOWED SLIDE DISARMED FOR SHORT TIME DURING DESCENT. FLIGHT ATTENDANTS REPORTED A DOOR SQUEAL STARTED AT THE SAME TIME. ADJUSTED DOOR STOPS PER AMM TO IMPROVE SEAL COMPRESSION AND IMPROVE DOOR HANDLE SECURITY. BOTH IMPROVEMENTS WOULD SDR 2005UALA01206Skin · gougedTHREE EACH GOUGES FOUND IN RVSM AREA ON RIGHT SIDE OF AIRCRAFT. DAMAGE IS APPROXIMATELY SIX INCHES FORWARD OF FORWARD CARGO DOOR. BLENDED DAMAGES TO REPAIR, REF. SRM53-11-11 AND SRM 53-00-11.SDR 2005UALA00833Hydraulic System · failedGREEN HYDRAULIC SYSTEM FAILURE AND YELLOW SYSTEM OVERHEAT.SDR 2002UALA01718Duct · leakingFLIGHT DIVERTED DUE TO A LEFT WING BLEED MESSAGE. FOUND SOURCE OF LEAK AT HIGH PRESSURE GROUND AIR CONNECTION DUCT/CLAMP. REPLACED DUCT AND CLAMPS.SDR 2002UALA00923Blade · failedRIGHT ENGINE FAILED. BORESCOPE INSPECTION REVEALED FAILED HIGH PRESSURE COMPRESSOR STAGE 4 BLADES, CAUSING MAJOR INTERNAL ENGINE DAMAGE AND AUTO-SHUTDOWN. ENGINE WAS REPLACED.SDR 2002UALA00920Bleed Valve · failedNR 2 ENGINE EXPERIENCED A HUNG START. HPC BLEED VALVE TEST REVEALED FAILED HPC 7C BLEED VALVE AND WEAK HPC 7A SOLENOID VALVE. VALVES REPLACED.SDR 2002UALA00214Light · inoperativeSEATS 19, 21 LEFT EMERGENCY ESCAPE PATH LIGHTING INOPERABLE. REPLACED EMERGENCY LIGHT ASSEMBLY.SDR 2001UALA02075Blade · crackedNR 1 ENGINE FAILURE. IN FLIGHT SHUT DOWN DUE TO ENGINE FAILURE CAUSED BY HIGH PRESSURE COMPRESSOR (HPC) 6TH STAGE BLADE CRACKING/LIBERATION AT ROOT. INSTALLATION OF NEW DESIGN OF C6 BLADES.SDR 2001UALA01586Computer · faultyUNSCHEDULED LANDING DUE TO LOSS OF NR 1 ENGINE BLEED. *S/D* FOUND LEAKING CLAMPS AT GROUND AIR START CONNECTION (FIXED PROBLEM ON NR 1 BLEED), AND REPLACED NR 2 BLEED AIR MONITORING COMPUTER FOR NR 2 BLEED PROBLEM. NO FURTHER DISCREPANCIES HAVE BEEN REPORTESDR 2000UALA00138B-Nut · looseRETURN TO SFO DUE TO LOSING OIL IN NR 1 ENGINE. *S/D* FOUND FUEL COOLED OIL COOLER (FCOC) OUTLET LINE LEAKING AT FITTING (REF A320 IPC 79-21-09-80 /ITEMS 110 & 120). TIGHTENED ONE HALF TURN. REPLACED SCAVENGE OIL FILTER AND CHECKED MAGNETIC CHIP DETECTOR.
Back to N435UA