What was found
GEN 2 FAULT DISPLAYED ON UPPER ECAM. NR 2 ENG IDG WILL NOT COME ONLINE UNTIL MANUALLY SELECTED, ALL PARAMETERS NORMAL AFTER SELECTION. RMV'D NR 2 ENG IDG. REMOVED MR24212-40978. BREAKERS T27 AND T25 PULLED AND COLLARED. RPLC'D IDG AGAIN, STILL NO HELP. FOUND WIRE NR 8 PO51W20 POS 7 (CONNECTOR 4000XUA) DAMAGED AND WIRE STRANDS BROKEN. DAMAGE IS INSIDE 90 DEG BACK SHELL AT IDG. RMV'D DAMAGED WIRING AND REPLACED CONNECTOR. REPAIRED WIRING ON NR 2 IDG.