N438UP
Service difficulty reports · 217
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N438UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N438UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2015012685445Floor Panel · delaminatedINSPECTION TYPE:CP11, MCD FLOOR PANEL 231XFF RT SIDE EDGE IS DELAMINATED THE ENTIRE LENGTH OF THE PANEL. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015012185377Floor Panel · damagedINSPECTION TYPE: CMCD, FLOOR PANEL 231XLF DAMAGE TO THE HONEYCOMB ON ONE EDGE. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2015011685306Floor Panel · damagedFLOOR PANEL 231XNF, HONEYCOMB MATERIAL IS RIPPED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011685304Floor Panel · damagedINSPECTION TYPE: CMCD, FLOOR PANEL 231XAF HAS SEVERAL DENTS AND HONEYCOMB MATERIAL MISSING AT FWD AND AFT EDGES. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011685303Floor Panel · damagedINSPECTION TYPE:CMCD, FLOOR PANEL 232XUF HAS DAMAGED HONEYCOMB. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011685302Floor Panel · damagedINSPECTION TYPE: CMCD, FLOOR PANEL 231XSF HONEYCOMB IS DAMAGED AT SEVERAL SPOTS AROUND THE EDGES. FABRICATED A NEW FLOOR PANELIAW SREO B757-5320-9692-H.SDR IPXA2015012685444Floorboard · damagedINSPECTION TYPE: CP11, MAIN DECK FLOORBOARD 252XUF DAMAGED IN CORNER 122-0141. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H, PN 146N5361-45.SDR IPXA2015012685443Floor Panel · delaminatedINSPECTION TYPE: CP 11, PANEL RACK MAIN DECK FLOOR PANEL 251XQF HAS A AREA OF DELAMINATION AT PREVIOUS. FABBED PANEL 251XQF, PN 146N5361-15 FROM A402H-48X144 IAW SREO B757-5320-9692-H2. STEP B2 OF SREO B757-5320-9692-H REQUIRED. SCUFF SAND AROUND THE STEP CSDR IPXA2015011685312Floorboard · puncturedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 252XEF HAS PUNCTURE. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2010116585311Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 241XMF DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO 5320-9692-H.SDR IPXA2015011685310Floorboard · damagedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 242XMF DAMAGED ON UNDERNEATH SIDE. FABRICATED FLOORBOARD IAW SREO 5320-9692-H.SDR IPXA2015011685309Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 241XKF DAMAGED AT INSERT. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015011685307Floorboard · puncturedINSPECTION TYPE: C, MAIN DECK FLOORBOARD 241XGF PUNCTURED. FABRICATED A NEW FLOORBOARD IAW SREO 5320-9692-H.SDR IPXA2015011685305Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 242XAF DELAMINATED IN CORNER. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2014091984349Transmitter · failedRT HYD SYS EICAS MESSAGE DURING DESCENT. EMERGENCY DECLARED, RAN QRH PROCEDURE. NO OTHER PROBLEMS NOTED. RT HYD QTY STAYED AT .94. DIDN'T OBSERVE ANY OVERHEAD HYD PRESSURE LIGHTS. HYD MAINT PAGE SHOWS RT HYD SYS PRESSURE AUTO EVENT. CREW REPORTED NO OTHERSDR IPXA2014050982914Guard · brokenEMERGENCY EXIT LIGHT SWITCH, A PIECE OF PLASTIC PART OF THE SPRING FELL OUT WHILE TURNING IT OFF. REPLACED SWITCH GUARD. OPS CHECKED NORMAL.SDR IPXA3576800Skin · dentedINSPECTION TYPE:C10, RT WING NR 6 SLAT UPPER AREA COMPOSITE DENTED. FABRICATED AND INSTALLED A REPAIR IAW SRM 57-41-02-2R-1, MAJOR REPAIR.SDR IPXA3576797Skin · damagedINSPECTION TYPE:C10, RT WING NR 6 SLAT WEDGE UPPER SURFACE 19" FROM OTBD EDGE. FABRICATED AND INSTALLED A REPAIR IAW SRM 57-43-02-2R-1, MAJOR REPAIR.SDR IPXA3576801Floorbeam · corrodedINSPECTION TYPE: C10, MAIN CABIN UNDER FLOORBEAM TEE CORRODED BS 1055, RBL 0-25, CORRODED OUT OF LIMITS. R & R FLOORBEAM TEE IAW DWG 144N5005.SDR IPXA3576798Floorbeam · corrodedINSPECTION TYPE:C10, MAIN CABIN UNDER FLOORBEAM TEE CORRODED BS 1055, RBL 25- RBL-50 CORROSION OUT OF LIMITS. R & R FLOORBEAM TEE IAW BAC DWG 144N5005, MINOR REPAIR.SDR IPXA3576795Floorbeam · corrodedINSPECTION TYPE: C10, MAIN CABIN UNDER FLOORBEAM CORRODED BS 1040, RBL 0-25 CORRODED OUT OF LIMITS. R & R TEE IAW DWG 144N5005. MINOR REPAIR.SDR IPXA12575967Wedge · dentedNR 4 SLAT T/E WEDGE DENTED AND DEBONDED. REPAIRED REF EOB757-5750-48728-B.SDR IPXA12572787Window · bindingCAPTAIN`S L2 SLIDING WINDOW LOCK IS BINDING BADLY AFTER PRESSURIZING THE ACFT. ADJUSTED NR 2 WINDOW IAW AMM 56-11-02-5. OPS CHECKED NORMAL.SDR IPXA1568462Skin · damagedCONVERT LIGHTNING STRIKE TEMP REPAIR AT FS 263 S-20R TO PERM ACCOMPLISH REPAIR IAW APP A, PREPAIRED IAW EO B757-5330-34712-B.SDR IPXA1568461Skin · damagedCONVERT LIGHTNING STRIKE TEMP REPAIR AT FS 247 BELOW S20R TO PERM ACCOMPLISH PERM REPAIR IAW APP A. REPAIRED IAW EO B757-5330-34705B.SDR IPXA1568460Skin · damagedDAMAGE TO FUSELAGE STA 231 BELOW STR 20R. REPAIRED IAW EO B757-5330-34712-B.SDR IPXA1568314Skin · damagedSKIN DAMAGED STA 231 BELOW S20R. REPAIRED REF EOB757-5330-34704-B.SDR IPXA11568321Skin · damagedLIGHTNING STRIKE REPAIR AT STA 418 JUST BELOW STR 23 RT. REPLACE TEMP FASTENERS IN REPAIR WITH SOLIDS IAW EO B757-5330-34715-B.SDR IPXA1565043Bracket · crackedINSPECTION TYPE:MOD, NR1 PYLON UPPER AFT INBD BRACKET ASSY IS CRACKED IN RADIUS, PPS 187, RBL 10, PN 312N5817-36. REPLACED BRACKET IAW SRM 51-40-02-0G.SDR IPXA11564911Support Bracket · crackedINSPECTION TYPE:C1, CRACKED CEILING SUPPORT BRACKET BS 520, BL 0, WL 202, IN FWD CARGO BAY. R & R BRACKET IAW SRM.SDR IPXA11564850Access Panel · damagedINSPECTION TYPE:MOD, NR 2 PYLON UNDERWING FAIRING STRUCTURE, OTBD AFT ACCESS PANEL NR 443ER HAS A DAMAGED FASTENER HOLE, LOCATED AT THE FWD LWR CORNER P/N 313N5004-4. FABRICATED NEW ACCESS PANEL NR 443ER IAW SRM 51-40-05-0G, SRM 51-40-08-0G, DWG 313N5004, AMMSDR IPXA1564724Sill · damagedINSPECTION TYPE:C1, FWD ENTRY DOOR SILL WEB ASSY HAS SEVERAL SCREW STRIKES AT BS 297-321. REMOVED DAMAGED WEB, FABRICATED AND INSTALLED NEW WEB, IAW SRM 53-10-15-1A.SDR IPXA1564772Floor Panel · damagedINSPECTION TYPE:C1, MAIN CARGO FLOOR PANEL MISSING INSERTS BS 1320-1420, LBL 25-45. FABRICATED NEW BOARD IAW EO 757-5320-9692-G.SDR IPXA1564774Angle · crackedINSPECTION TYPE:MOD NR1 PYLON AFT FAIRING STRUCTURE INBD AND OTBD NUT PLATE. SUPPORT BRACKETS ABOVE DRAIN LINES ARE CRACKED. R & R INBD AND OTBD SUPPORT BRACKETS IAW SRM 51-40-02-0G.SDR IPXA1564802Support Bracket · crackedINSPECTION TYPE:MOD, NR2 PYLON AFT FAIRING STRUCTURE INBD AND OTBD NUTPLATE SUPPORT BRACKETS ABOVE DRAIN LINES ARE CRACKED AND WORN. R & R BOTH INBD AND OTBD NUTPLATE SUPPORT BRACKETS IAW SRM 51-40-02-0G.SDR IPXA1564727Floorboard · damagedINSPECTION TYPE:C1, MAIN CARGO FLOORBOARD. BS 560-620, LBL 45-65 HAS MISSING INSERT. REPLACED FLOORBOARD ASSY IAW EO B757-5320-9692-G, SRM 53-00-50-1A1.SDR IPXA1564719Floor Panel · delaminatedINSPECTION TYPE:C1 MAIN CARGO FLOOR PANEL BS 338-440 RBL 25 IS DELAMINATED AND HAS MISSING INSERTS. REPAIRED IAW EO B757-5320-9692-G, DATED: 04/15/2009.SDR IPXA1564718Floor Panel · delaminatedINSPECTION TYPE:C1, FLOOR PANEL, BS 333-440 LBL 25, HAS DELAMINATION ON LOWER SURFACE AND A MISSING INSERT. REPAIRED IAW EO B757-5320-9692-G, DATED 04/15/2009.SDR IPXA1564950Fitting · corrodedINSPECTION TYPE:MOD, NR 1 PYLON MID SPAR FITTING ON THE ACFT INBD SURFACE AROUND THE BUSHING IS PITTED AND WORN. REPAIRED FITTING IAW EO B757-5440-41606-A, DATED 24 FEB 2011 AND ATS ER 11-01495, DATED 23 FEB 11.SDR IPXA1564949Fitting · gougedINSPECTION TYPE:MOD, NR 1 PYLON INBD MID SPAR FITTING ON ACFT INBD AND OTBD SURFACE AROUND THE BUSHING ARE WORN AND GOUGED. REPAIRED FITTING IAW EO B757-5440-41606-A AND ER 11-01495.SDR IPXA1564947Skin · chafedINSPECTION TYPE:MOD, RT WING LOWER SKIN AT FSS 295 IS CHAFED FROM 7-14 INCHES AFT OF THE SKIN L/E. REPAIRED IAW SRM 57-20-01-1A1, EO B757-5730-41559-A, DATED 23 FEB 2011, AND ATS ER 11-01575 DATED 23 FEB, 2011.SDR IPXA1564946Skin · chafedINSPECTION TYPE:MOD, LT WING LOWER SKIN IS CHAFED AT FSS 295, FROM 2-14 INCHES AFT OF THE SKIN L/E. REPAIRED IAW SRM 57-20-01-1A1, ATS ER 11-01575, DATED 23, FEB 2011, EO B757-5730-41559-A DATED 23, FEB 2011.SDR IPXA11564860Support · wornINSPECTION TYPE:MOD, NR 2 PYLON AFT FAIRING STRUCTURE FWD INBD UPPER NUT PLATE SUPPORT WORN AROUND LOWER NUT PLATE. FABRICATED NEW FWD INBD UPPER NUT PLATE SUPPORT IAW SRM 54-50-71-1A1, SRM 51-30-01-0G, SRM 51-40-05-0G, AMM 51-21-11-7, AMM 51-21-10-7.SDR IPXA11564848Support · wornINSPECTION TYPE:MOD, NR 2 PYLON AFT FAIRING STRUCTURE FWD OTBD UPPER NUTPLATE SUPPORT WORN AROUND NUTPLATES. REMOVED, FABRICATED AND INSTALLED NEW NUTPLATE SUPPORT IAW SRM 54-50-70-1A1, SRM 51-40-02-0G, SRM 51-40-05-0G, AMM 51-21-10-7, AMM 51-21-11-7.SDR IPXA1564773Skin Panel · crackedINSPECTION TYPE: MOD, NR2 PYLON AFT FAIRING STRUCTURE LOWER AFT CLOSE-OUT SKIN CRACKED ABOVE DRAIN LINE. R & R LOWER AFT CLOSE-OUT SKIN IAW SRM 51-40-02-0G.SDR IPXA1564748Fairing · gougedINSPECTION TYPE:MOD, NR1 PYLON AFT FAIRING STRUCTURE FWD INBD UPPER NUTPLATE SUPPORT IS WORN AROUND NUTPLATES. REMOVED, FABRICATED, AND INSTALLED IAW DWG NR313N5033, AND SRM 51-40-02.SDR IPXA1564786Skin · crackedINSPECTION TYPE:MOD, NR1 PYLON AFT FAIRING STRUCTURE LOWER T/E SKIN PANEL IS CRACKED ABOVE DRAIN LINES. R & R SKIN PANEL IAW SRM 51-40-02-0G.SDR IPXA1565012Floorbeam · damagedINSPECTION TYPE:C1, FLOORBEAM STA 900, RBL 25-45 HAS MECH DAMAGE. R & R FLOORBEAM IAW SRM.SDR IPXA1564951Shear Web · corrodedINSPECTION TYPE:C1, SEVERAL AREAS OF CORROSION ON SHEAR WEB (MARKED) AT BS 440-BS 660, LBL 45-LBL 60, WL 208. REPAIRED IAW SRM 51-10-02-0G, SRM 53-30-15-0I1, SRM 51-40-02-0G, ATS ER NO 11-01491 DATED 2/24/2011, AND EO B757-5310-41615-A, DATED 02/24/11.SDR IPXA1564939Floorbeam · corrodedINSPECTION TYPE:C1, CORROSION ON BS 1681 FLOORBEAM, LBL 40 ON THE UNDERSIDE OF THE J FLANGE. REPAIRED IAW ATS ER 11-01477, DATED 2/24/11.