N444UP
Service difficulty reports · 206
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N444UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N444UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2020111762488Frame · corrodedINSPECTION TYPE: SEG RT FUSELAGE AFT OF THE RAT DOOR, HAS A CORROSION ON FRAME 1240. REPAIR AREA, PER EA 757-5311-27-A2527 REV-.SDR IPXA2020111462361Floor Panel · damagedINSPECTION TYPE: SEG MAIN CARGO COMPARTMENT FLOOR PANEL 242XHF DAMAGED. FABBED PANEL 242XHF FROM 5024N400001SS-G BATCH3 3489461, PER SREO B757-5320-9692-K.SDR IPXA2020111462360Floor Panel · damagedINSPECTION TYPE: SEG MAIN CARGO COMPARTMENT FLOOR PANEL 242XMF DAMAGED. FABBED PANEL 242XMF FROM 5024N400001SS-G BATCH 3489461, PER SREO B757-5320-9692-K.SDR IPXA2020111462363Skin · delaminatedINSPECTION TYPE: SEG RT WING OUTBOARD FLAP UPPER SURFACE DISBOND ON THE TRAILING EDGE. REPAIRED IAW SRM B757 51-70-07-OG, PER SRM 57-53-01-2R-1 250 DEGREES AT 90 MINS.SDR IPXA2020111462362Skin · delaminatedINSPECTION TYPE: SEG RT WING OUTBOARD UPPER SURFACE DISBOND ON THE TRAILING EDGE. REPAIRED IAW SRM B757 B757 51-70-07-OG, PER SRM 57-53-01-2R-1 250 DEGREES AT 90 MINUTES.SDR IPXA2019121349955Anti-Ice Valve · faultedINSPECTION TYPE:N/AATB - DURING CLIMBOUT TURNED ON ENGINE ANTI ICE R/H ANTI ICE VALVE DID NOT OPEN VAVLE LIGHT ON SWITCH AND EICAS MESSAGE DISPLAYED.REMOVED AND REPLACED RH ENGINE (INLET-ILLEG) TAI VALVE PER MM 30 21 03 004 017SDR IPXA2018072432040Unknown · odorWITH LEFT PACK ON, ABNORMAL/STRANGE ODOR WAS PRESENT. UPON DESCENT, ODOR CLEARED. PERFORMED OPERATIONAL CHECK OF LT PACK SYSTEM, REF AMM 21-00-00-862-001. CHECKS GOOD. NO ODOR NOTED.SDR IPXA2018071831819Warning System · false activationGOT INTERMITTENT L FWD ENT DOOR EICAS & OVERHEAD ENTRY DOORS LT WITH ENTRY DOOR SHUT. ACCOMPLISHED OPS CK ON CREW ENTRY DOOR IAW AMM 52-71-00-735-053. OPS CK GOOD.SDR IPXA2017030614773Hook · detachedFIRST OFFICER`S EMERGENCY ESCAPE ROPE DOOR BOTTOM HOOK IS DETACHED FROM DOOR. ATTACHED THE HOOK IAW MM 25-00-00-801-300-806.SDR IPXA2017021013902Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 231XFF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J, AND SRM 53-00-50-2R-1.SDR IPXA2017021013905Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 231XJF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2017020613766Floor Panel · damagedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 241XKF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2017020913874Floor Panel · damagedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 242XJF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2017020913873Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 241XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2017020913872Floor Panel · damagedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 241XJF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2017020913871Floor Panel · damagedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 241XMF HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-96925-J.SDR IPXA2017020613764Floor Panel · delaminatedINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 242XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-J.SDR IPXA2016021799511Switch · brokenEMERGENCY LIGHTS UNARMED LIGHT SWITCH BROKEN. R & R EMERGENCY LIGHTS & OXYGEN CONTROL PANEL IAW MM 33-51-08-404-011. OPS CK GOOD IPC 33-51-08-04.SDR IPXA2015092093719Floor Panel · damagedMCD FLOOR PANEL, BS 1620, POS 15R DAMAGED, FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2015083192898Floorboard · damagedMAIN CARGO DECK FLOORBOARD DAMAGED AT POS 15RT, BS 1600, FABRICATED A NEW FLOORBOARD IAW EO B757-5320-9692H.SDR IPXA2015030686697Skin · dentedINSPECTION TYPE:C-11, EXTERIOR FUSELAGE SKIN DENTED APPROXIMATELY BS 1850, BELOW S18R. REPAIRED IAW EO B757-5330-56877-A AND REO G18789, REV A.SDR IPXA2015021986098Floor Panel · crackedINSPECTION TYPE:C11, FLOOR PANEL 211XAF IS CRACKED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2015021685965Floor Panel · crackedINSPECTION TYPE:C11, MAIN CABIN FLOOR PANEL 333XHF HAS 2 EA DAMAGED INSERTS. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692H.SDR IPXA2015021886058Floor Panel · damagedINSPECTION TYPE:C11, MAIN CARGO CABIN FLOOR PANEL 231XWF IS CRUSHED IN SEVERAL PLACES. FABRICATED NEW FLOORBOARD.SDR IPXA2015021886052Floorboard · crackedINSPECTION TYPE:C11, MAIN CABIN FLOORBOARD 232XGF IS CRACKED. FABRICATED A NEW FLOORBOARD.SDR IPXA2015021685968Floorboard · crackedINSPECTION TYPE: C11, MAIN CABIN FLOORBOARD 231XHR IS CRACKED. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014063083440Battery Pack · inoperativeDURING ENGINE START, RT EMERGENCY EXIT EICAS LIGHT ILLUMINATED ALONG WITH OVERHEAD LIGHT. R & R EXIT LIGHT BATTERY IAW MM 33-51-07. OPS CHECKED OK.SDR IPXA2014062783414Battery Pack · inoperativeEMERGENCY EXIT LIGHTS EICAS ILLUMINATED ALONG WITH OVERHEAD LIGHT. R & R EXIT LIGHT BATTERY IAW MM 33-51-07.SDR IPXA2013511180868Skin · delaminatedRT OTBD AFT FLAP LOWER SKIN INBD CORNER DAMAGED. REPAIRED IAW EO B757-5750-52706-A.SDR IPXA3577501Cowling · corrodedINSPECTION TYPE:C-10, NR 2 ENGINE OTBD T/R SKIN ACCESS PLATE AND FASTENERS CORRODED REMOVED AND REPLACED NR 2 OTBD T/R.SDR IPXA13577286Transition Panel · corrodedINSPECTION TYPE:C-10, FORWARD CARGO COMPARTMENT FLOOR TRANSITION PANEL CORRODED AROUND TIE DOWN ANCHOR POINTS AT BS660-760, RBL 22. REMOVED CORROSION FWD CARGO COMPARTMENT FLOOR TRANSITION PANEL AROUND TIE DOWN ANCHOR POINTS BS660-BS760, RBL22 ORIGINAL MAT'L SDR IPXA13577285Transition Panel · corrodedINSPECTION TYPE:C-10, FORWARD CARGO COMPARTMENT FLOOR TRANSITION PANEL CORRODED AROUND TIE DOWN AT BS620-640, RBL22. REMOVED CORROSION FWD CARGO COMPARTMENT FLOOR TRANSITION PANEL AROUND TIE DOWN ANCHOR POINTS ORIGINAL MAT'L THICKNESS .063 REMOVED .004 REMAINSDR IPXA13577284Transition Panel · corrodedINSPECTION TYPE:C-10, FORWARD CARGO COMPARTMENT FLOOR TRANSTITION PANEL CORRODED AROUND TIE DOWN AT BS780-820, RBL22. REMOVED CORROSION FWD CARGO COMPARTMENT FLOOR TRANSITION PANEL AROUND TIE DOWN ANCHOR POINTS BS780-BS820, RBL 22. ORIGINAL MAT'L THICKNESS .SDR IPXA3577473Floorboard · brokenINSPECTION TYPE:C10, MAIN CABIN FLOORBOARD 242XCF BROKEN. FABRICATED NEW FLOORBOARD IAW B757-5320-9692-H.SDR IPXA11570015Roller · defectiveFLIGHT CREW REPORTED THE CAPT'S WINDOW WAS DIFFICULT TO OPEN AFTER FLIGHT. FOUND THE UPPER CENTERING ROLLER BEARING AND BRACKET TO BE DEFECTIVE. R & R THE BEARING AND BRACKET AND THE WINDOW OPS CHECKED GOOD.SDR IPXA11566248Deck Plate · corrodedINSPECTION TYPE:C1 ACCOMPLISH REPAIR TO AFT SHEAR WEB IAW ATS ER 11-02237, BS 1681 RBL 26 TO RBL 45, WL 208 ATS ER 11-02237 AND EO B757-5310-42499-A.SDR IPXA11566050Strap · crackedINSPECTION TYPE:C1, FWD SIDE OF 9G WALL, THIN STRAP, AT STR 1 CRACKED, MARKED REPLACED IAW SRM 51-40-02-0G.SDR IPXA11566040Floor Panel · delaminatedINSPECTION TYPE:C1, MAIN CARGO BAY FLOOR PANEL BS 620-720 BL0-RBL 25 HAS DELAMINATED EDGE (DAMAGE BEYOND SRM LIMITS). FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA11566088Bracket · crackedINSPECTION TYPE:C1, WHILE WORKING CARD 930097, FOUND APU FIRE BOTTLE MOUNT BRACKET FLANGE STIFFNER CRACKED. REPLACED BRACKET IAW SRM 51-40-04-0G, SRM 51-40-05-0G, DWG PL 355N5207 REV C, AMM 51-21-10-7, SRM 51-10-02-0G, STEP 9.SDR IPXA11566082Angle · crackedINSPECTION TYPE:C1, WHILE WORKING CARD NR 930340, FOUND NR 2 ENG OTBD THRUST REVERSER TO HAVE CRACKED ANGLE ADJACENT TO L/E RUBSTRIP,27" ABOVE LWR INBD END OF COWL. REPLACED FRAME IAW SRM 51-40-02-0G, SRM 51-40-05-0G, AMM 51-21-10-7, SRM 51-10-02-0G, STEP 9.SDR IPXA11566111Structure · wornINSPECTION TYPE:C1, WHILE ACCESSING FOR INTERCOSTAL (CARD 930410) FOUND SCREW AND INSERT WEAR AT 4 EA LOCATIONS ON INNER CHORD BS 297 TO BS 324 LBL 62. R & R INNER CHORD IAW SRM 51-40-05-0G, 51-20-01-0G, 51-40-02-0G AND MM 25-00-00-7.SDR IPXA11566180Angle · damagedINSPECTION TYPE: NR 1 INBD SIDE A, HAD DOOR GUIDE CLIP AFT OF HINGE IS DAMAGED. REPLACED CLIP (ANGLE) IAW SRM 51-40-02-0G, DWG 311N5002, BDW 311N5196, SRM 51-40-05-0G, SRM 51-10-02-0G.SDR IPXA11566109Skin · gougedINSPECTION TYPE: MOD NR 2 PYLON INBD SIDE GOUGE ON PYLON EXTERNAL SKIN 4.5" AFT OF T/R HINGE. REPAIRED IAW ER 11-02315, AND EO B757-5450-42265-A.SDR IPXA11566220Floorbeam · corrodedINSPECTION TYPE:C1, FLOORBEAM FWD FLANGE HAS CORROSION AT FASTENER HOLES BETWEEN 0 - LBL 23 STA 1100. REPAIRED IAW ATS ER 11-02314.SDR IPXA11566110Angle · crackedINSPECTION TYPE: MOD LT AFT FAIRING STRUCTURE, UPPER INBD AFT WIRE SUPPORT ANGLE IS CRACKED AND BROKEN, PN 287N1112-12. REPLACED IAW SRM 51-40-02-0G.SDR IPXA11566084Angle · gougedINSPECTION TYPE: MOD, RT AFT FAIRING STRUCTURE FWD RT VERTICAL ANGLE IS GOUGED IN RADIUS. REMOVE, FABRICATED AND INSTALL IAW DWG 313N5033 AND SRM 51-40-02.SDR IPXA11566083Doubler · gougedINSPECTION TYPE:MOD, RT AFT FAIRING STRUCTURE FWD RT NUTPLATE SPLICE MACHINED DOUBLER IS GOUGED ON THE TOP INBD SIDE AND CHANGED ON THE OTBD SIDE. REMOVE, FABRICATED AND INSTALL IAW DWG 313N5025, AND SRM 51-40-02.SDR IPXA11565965Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD AT STA 620-720. RBL 45 TO RBL 60 HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565964Floorboard · damagedINSPECTION TYPE:C1, FLOORBOARD AT STA 1020-1055, RBL 45 TO RBL 60 HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565960Floor Panel · damagedINSPECTION TYPE:C1, MCB FLOOR PANEL BS 1100-1200, LBL 25 TO LBL 45 HAS DAMAGED CORNER. FABRICATED MCB FLOOR PANEL BS 1100-1200 LBL 25 TO LBL 45 IAW SRM 53-00-50 1A1, AMM 53-01-01-4.