N445UA
Service difficulty reports · 131
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N445UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N445UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017092503333Light · malfunctionedRT SIDE OVERWING EXIT DOOR LIGHT ILLUMINATED RESET EMERGENCY LIGHT SYSTEM SWITCH, RT OVERWING EXIT DOOR LIGHT OPS CHECKED NORMAL.SDR CALA2017072102306Oven · faultyPER INBD FLT ATTN, AFT GALLEY OVEN R42 VERY HOT AFTER 10 MIN ON, OVEN CB R42 TRIPPED, G3 GALLEY CB PANEL VERY HOT, PER INBD FLT ATTN WHEN OVEN DOOR OPENED ELECTRIC SMELL. REMOVED AND REPLACED OVEN AT LOCATION R42 IAW AMM 25-35-19. OPS CHECK GOOD.SDR CALA2017060501732Battery · faultedRIGHT EPSU BATTERY FAULT LIGHT DURING TEST. REPLACED THE BATTERY IAW AMM 33-51-38, TESTED OK.SDR CALA2017020600291Power Supply · faultyPER 2SVC EMERGENCY LITE TEST FAIL ON CIDS PANEL. HAVE EPSU INT LOAD EMER L MSG. RPLD LT OW POWER SUPPLY, TEST PASS.SDR CALA2016072895587Landing Gear · malfunctionedLANDING GEAR INDICATION RIGHT MAIN NOT DOWN AND LOCKED. GO AROUND AFTER WHILE DOWNLOCK OK. GROUND SCAN OF BOTH LGCIUS AND ALSO TESTS OF LGCIU. NO FAULTS DETECTED. BITE CHECKED WITH MCDU TO ENSURE GEAR NOT DOWN FOR LANDING WARNING OPERATIVE TEST OK.SDR CALA2016060195427Keelbeam · damagedKEEL BEAM HAS SEVERAL OUT OF ROUND HOLES. REPAIRED ALL HOLES IAW ECRA 5330-05712.SDR CALA2016060195424Stringer · crackedLEFT FUSELAGE FRAME 35, STRINGER 30 IS CRACKED. REPAIRED IAW ECRA 5330-05705.SDR CALA2016052395405Skin · gougedEXTERIOR FUSELAGE SKIN IS GOUGED AT 3.5 INCHES BELOW STRINGER 31L & ON FRAME 34 OUT OF LIMITS. CUT OUT DAMAGED SKIN FABRICATED & INSTALLED DOUBLER & FILLER.SDR CALA2016050695349Door Sill · corrodedAFT CABIN WET AREA, CORROSION AT LT 2 DOOR THRESHOLD SILL, AT FRAME 66. REMOVED DAMAGED PARTS & INSTALLED REPAIRED DOUBLER & GIRT BAR FITTING PLATE.SDR CALA2016050695348Frame · damagedFRAME 15, AFT SIDE WEB DAMAGED, APPROX AT STRINGER 2L. REPAIRED FRAME 15 TD-P1-52-19995-2016 & SRM 51 -42-11, 51-21-11 & 51-75-12.SDR CALA2016050495327Shear Tie · corrodedFORWARD CARGO BAY SHEAR TIE AT FRAME 33, BETWEEN STRINGER 44 - 43LT, HAS CORROSION. R & R SHEAR TIE AT FRAME 33, BETWEEN STRINGER 44 - 43LT.SDR CALA2016050495323Door Sill · corrodedL2 DOOR AFT GIRT BAR FITTING HAS CORROSION LEACHING OUT FROM UNDER ADJUSTMENT PLATE & SCUPPER. REMOVED CORROSION FROM L2 DOOR SILL FRAME 68, FOUND TO BE OUT OF LIMITS. FABRICATED REPAIR & INSTALLED. INSTALLED GASKET & STEEL PLATE ASSEMBLY ECRA 5100-02464.SDR CALA2016050495322Stringer · corrodedAFT CARGO BAY, STRINGER 43L HAS CORROSION IN 3 PLACES, APPROX 3 INCHES AFT FRAME 56, 9 INCHES FWD FRAME 57 & 3 INCHES AFT FRAME 59. R & R CARGO BAY STRINGER 43L.SDR CALA2016050495338Fitting · corrodedL2 DOOR FWD GIRT BAR FITTING INBD AFT NUTPLATE CORRODED. CORROSION ON L2 DOOR SILL FWD GIRT BAR FITTING, 2 EACH NUTPLATE HOLES FOUND TO BE OUT OF LIMITS. FABRICATED REPAIR & INSTALLED ON NON-ROUTINE 38574.SDR CALA2016042895318Door Sill · corrodedR2 DOOR SILL HAS CORROSION AT FRAME 66. REPLACED R2 DOOR SILL IAW SRM 51-42-11 & 51-72-11.SDR CALA2016042895317Frame · damagedLEFT UPPER FUSELAGE FRAME 47, BUTT JOINT HOLE 35 AT STRINGER 7, HAS REJECT ABLE NDT INDICATIONS. REAMED HOLE IAW SRM 51-43- 00. NDT IAW NTM51-10-01, NO INDICATIONS. FINAL REAM & COLD WORK IAW SRM 51-43-00 & EA 5330-04861 OP 1.SDR CALA2016042695301Cleat · corrodedFRAME 31 CLEAT, BETWEEN STRINGER 43L & 43R, HAS CORROSION. R & R CLEAT FRAME 31 IAW SRM 51-42-11-001 & 53-21-12, NO FURTHER DAMAGE NOTED IN AREA.SDR CALA2016020495089Slide · defectiveDOOR 2R ARMING LEVER WILL NOT STAY FLUSH WITH DOOR. INSTALLED SERVICEABLE R2 DOOR SLIDE PACK IAW AMM 25-62-44. OPERATIONS CHECKED ARMING LEVER SEVERAL TIMES, NO DEFECTS NOTED AT THIS TIME.SDR CALA2015092994547Slide · unsecureARMING ISSUE, LEVER DOOR 2R WHEN AIRBORNE LIFTED SLIGHTLY & BACK FLUSH AFTER LANDING. REPLACED DOOR 2R SLIDE DUE TO IT SHIFTING IN BUSTLE & CAUSING ARMING ISSUES. REPLACED IAW MM 25-62-44.SDR CALA2014090992098Skin · damagedRIGHT ELEVATOR UPPER SURFACE HAD A 1.5 INCH X 1.5 INCH AREA OF WATER INGRESS, 26 INCHES FROM THE INBD END OF THE ELEVATOR & 26 INCHES FWD OF THE TE ZONE 1. DAMAGE WAS R & R ACP IAW SRM 55-21-11 PARA 5 E FIG 205 CONFIG 1. REPAIR REQUIRES INSPECTION IAW SRI55-SDR CALA2014050690957Warning System · false activationDURING GO AROUND, ECAM WARNING LG DOORS NOT CLOSED ECAM WARNING. GO AROUND INITIATED DUE TO TAILWIND CAUSING EXCESSIVE AIRSPEED. RECEIVED ECAM WHEN GEAR UP SELECTED, THROTTLES WERE ADVANCED, BUT NOT IN TO GO POSITION. MOVED GEAR HANDLE TO DOWN & NORMAL THRESDR CALA2014012190205Warning System · activatedAUTO FLT YAW DAMPER 2 DISPLAYED ON UPPER ECAM SCREEN.SDR CALA2013122693910Slide · unwanted deployINADVERTENTLY LT OVERWING SLIDE DEPLOYMENT DURING DISARM PROCEDURE. REPLACED LT OVERWING SLIDE IAW 25-62-42 & REPLACED LT OVERWING SLIDE INFLATION CYC IAW 25-62-46. ACCOMPLISHED TESTS IAW AMM, OPERATIONS CHECKED OK.SDR CALA2013111292855Fire Bottle · unserviceableFWD AFT LAVATORY FIRE EXTINGUISHER PRESSURE IN RED BAND. R & R FWD AFT LAVATORY FIRE EXTINGUISHER IAW AMM.SDR CALA2013081290354Computer · faultySLATS SLOW STATUS MESSAGE. REPLACED SFCC NR 2 IAW MM.SDR UALA2013050203053Fastener · missingON ARRIVAL, NR 2 ENGINE PYLON PANEL 482A MISSING ONE FASTENER FROM LOWER FWD EDGE. REPLACED FASTENER AND SECURED ADJACENT FASTENERS.SDR UALA2013040402239Visor · defectiveF/O'S SUNVISOR DEFECTIVE. REPLACED VISOR, OPS NORMAL.SDR UALA2013030601338Bottle · emptyL1 DOOR SLIDE AND ASSIST BOTTLE BLOWN. REPLACED SLIDE PACK AND THE EPSU LIGHTS ARE INOPERATIVE.SDR UALA2013030101228Vent Line · leakingAFT GALLEY HAS WATER ON FLOOR AGAIN. REMOVED AFT COFFEEMAKERS. VENT LINE HAS CONSTANT DRIP WITH WATER SUPPLY ON. BLED SYSTEM, NO HELP. AFT GALLEY WATER SUPPLY SHUT OFF AND INSTALLED COFFEEMAKERS. MOPPED UP WATER RESIDUE AS NEEDED. COMPLIED WITH MEL, PLASDR UALA2012091705241Slat · damagedBIRD STRIKE CLIMBOUT FROM 3000FT. REMOVED NR 2 SLAT PER MM 27-84-64-000-001 DUE TO DAMAGE. INSTALLED LEADING EDGE SLAT NUMBER 2 REF 27-84-64-400-002-A UP TO STEP B3 OF PAGE 8.SDR UALA2012091705216Slat · damagedBIRD STRIKE ON CLIMBOUT. LARGE SIZE LEFT ENGINE. REMOVED NR 2 SLAT PER MM 27-84-64-000-001 DUE TO DAMAGE. INSTALLED LEADING EDGE SLAT NR 2.SDR UALA2012091005076Modulating Valve · faultyNR 2 ENGINE IFSD, RTFL. CREW REPORTS RIGHT ENGINE OIL TEMP REACHED 175 DEG CELSIUS. UPPER ECAM WARNING, RIGHT ENGINE SHUTDOWN IN FLIGHT. REPLACED ACOC PER MM AND MODULATING VALVE PER MM. ALSO INSTALLED NEW TEMP SENSOR ON ACOC.SDR UALA2012083104895Mount · wornFORWARD LEFT APU MOUNT, O/B ATTACH EAR WORN ON THE INNER SIDE FROM CONTACT WITH THE WORN FWD SUPPORT ROD LOWER ROD END. REMOVED FASTENERS IN APU FIREWALL SKIN TO ACCESS FORWARD LEFT APU MOUNT. REMOVED MOUNT. INSTALLED MOUNT. OK TO INSTALL LEFT FORWARD MOUNSDR UALA2012081604546Controller · inoperativeCAPTAIN'S WINDSHIELD HEAT IS INOP. ACP MEL, LLR FAULTED L WINDSHIELD SENSOR GND OR L WINDSHIELD SENSOR. SENSOR 1 READS 614 OHMS, SENSOR 2 READS 613 OHMS, ELEMENT READS 12.3 OHMS AT 80F, ALL WITHIN LIMITS. REPLACED, VERIFIED SENSORS 1 & 2 WITHIN RESISTANCE SDR UALA2012081404492Structure · dentedDENT IN FUSELAGE, APPROX 6 FEET AFT OF DOOR 2L AND 1.5 FEET ABOVE FLOOR LINE. APPROX AT FRAME 70 AND STRINGER 20. DENT MEASURES 2" HIGH, 3" WIDE AND 1-32" DEEP. DENT WITHIN LIMITS.SDR UALA2012081604545Controller · faultyLEFT CAPT WINDOW HEAT ECAM. REMOVED AND REPLACED WHC L PER AMM AND INSTALLED JUMPER HARNESS WIRE PER MT. WINDOW PASSED MCDU TEST.SDR UALA2012070903682Oxygen Box · damagedDURING DROP TEST, FOUND SEATS 2AB O2 PANEL RESET BUTTON WILL NOT ENGAGE. REPLACED 02 BOX AND PERFORM DROP TEST PER MM. OPS CHECKED GOOD.SDR UALA2012070903680Oxygen Box · brokenDURING OXYGEN MASK DROP TEST, FOUND SEATS 28 DEF O2 PANEL PARTS BROKEN, PANEL WILL NOT RESET. FOUND DOOR ACTUATOR BENT AND JAMMED. REPLACED 02 BOX AND PERFORM DROP TEST PER MM. OPS CHECKED GOOD.SDR UALA2012051802839Module · faultedFIRST OFFICER LOST AIRSPEED INDICATIONS. FLT ABORTED. FIRST OFFICER LOST AIRSPEED INDICATIONS W- NUMEROUS ECAMS. FOUND ON POST FLT RPT ADM 19FP8 FAULT AND NR 3 ADIRU FAULT, REPLACED AMD PER AMM AND NR 3 ADIRU PER AMM. ACCOMPLISHED FULL RANGE TEST PER AMM, SDR UALA2011111006138Light · faultyELECTRICAL SMELL ROW 32. PROG TEXT: - ITEM ROLLED FORWARD. SAMC TEXT CONTACT SAMC, ALSO CHECK UNDER SEAT WIRING HARNESSES IN AREA FOR ANY EVIDENCE OF ELECTRICAL DAMAGE. INSPECTED AREA FOR DAMAGE. FOUND SIDEWALL LIGHT AT SEAT ROW 32ABC INOP. REPLACED SIDEWSDR UALA2011092605184Knob · unsecureCAPT WINDSHIELD WIPER KNOB FELL OFF. SECURED WINDSHIELD WIPER KNOB.SDR UALA2011072503780Outflow Valve · malfunctionedSYSTEM 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. REPLACED OUTFLOW VALVE.SDR UALA2011072603814Link · wrong partRECEIVED SLIDE MR25822-2212 IN PACKED CONDITION. UPON DISASSEMBLY FOUND ONE INCORRECT FRANGIBLE LINK INSTALLED AT THE SILL SUPPORT LOG. FRANGIBLE LINK INSTALLED WAS P/N C19347-107 (NATURAL/BLACK), SHOULD BE P/N C19749-103 (BLACK/ORANGE). DUE TO THE DIFFERENT BSDR UALA2011071503585Hinge · faultyOXYGEN COMPARTMENT DOORS FAILED TO OPEN DURING MANUAL RELEASE TEST (3 TRYS). FWD LAV AND FWD FLIGHT ATTENDANT SEAT. REMOVED CONTAINERS BOTH LOCATIONS. FOUND BAD HINGES. REPLACED FWD LAV CONTAINER AND REINSTALLED WIRE CONNECTION FOR FWD CONTAINER UNTIL A POSDR UALA2011071303504Door · out of adjustO2 COMPT DOORS FAILED TO OPEN DURING MANUAL RELEASE CHECK (3 TRYS) - SEAT ROWS 28L AND 37L. REMOVED O2 GENERATOR AND DROPPED CONTAINER FOR ACCESS. OPENED REPACKED ADJUSTED DOORS AND OPS CHECKED GOOD. FOUND MASKS BINDING DOOR.SDR UALA2011071303500Door · stuckTHE O2 COMPT DOORS FAILED TO OPEN DURING MANUAL RELEASE CHECK (3 TRYS) - SEAT ROWS 28L AND 37L. FROM BASE W-U J2052.SDR UALA2011071303503Door · out of adjustTHE O2 COMPT DOORS FAILED TO OPEN DURING MANUAL RELEASE CHECK (3 TRYS) - AFT FLIGHT ATTENDANT SEAT AND LAV D. OPENED CONTAINER FOUND ACTUATOR WORKING FINE. CHECKED BOX AND DOOR FOR ALIGNMENT RE-ADJUSTED BOX AND DOOR. OPS CHECKED FINE.SDR UALA2011071303501Door · out of adjustTHE O2 COMPT DOORS FAILED TO OPEN DURING MANUAL RELEASE CHECK (3 TRYS) - AFT FLIGHT ATTENDANT SEAT AND LAV 'D'. OPENED CONTAINER FOUND ACTUATOR WORKING FINE. CHECKED BOX AND DOOR FOR ALIGNMENT. ADJUSTED BOX AND DOOR OPS CHECKED FINE.SDR UALA2011062703136Support · brokenDOOR 2R ARMED ORANGE INDICATOR ON FLOOR BROKEN OFF. REPLACED DOOR 2R GIRT BAR ARMED SUPPORT AND VISUAL INDICATOR & OP CHK'D. ARMING THE DOOR & DISARMING AND ALSO, OP CKD OKAY.SDR UALA2011060302707Outflow Valve · defectivePRESSURIZATION ISSUE, RTFL. REPLACED FAN EXTRACT AND B LOWER & SKIN AIR OUTLET VALVE PER MM, PASSED AEVC TEST.
Back to N445UA