N446UA
Service difficulty reports · 151
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N446UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N446UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011021400776Container · delaminatedCREW REPORT: OXY PANEL ROW 27 ABC LOOSE. -O2 CONTAINER BOX IS DELAMINATING, SEPARATING FWD OTBD CORNER LOWER SURFACE. BOX IS SECURE IN OVERHEAD. AS PRECAUTION, APPLIED TAPE OVER CORNER, INOP SEATS 27ABC. WILL NEED NEW CONTAINER. SEATS PLACARDED INOP, REPLACED SDR UALA2010121704604Door · out of adjustSEAT 2AB OXYGEN CONTAINER BOX DOOR WILL NOT LATCH CLOSE. REPLACED SEAT 2AB O2 CONTAINER & PERFORMED DROP TEST. SEATS 6ABC, 12ABC, 18ABC, 19ABC, 21ABC, 25ABC, 3DEF, 6DEF, 8DEF, 24DEF AND 26DEF WOULD NOT DEPLOY WHEN TESTED. RESET & TRIED MULTIPLE TIMES WITH NO SDR UALA2010121404556Switch · faultedFOUND 13 VARIOUS ROWS O2 DOORS WILL NOT DEPLOY. RESET TRIED SEVERAL TIMES WITH SAME RESULTS. MOVING TO HANGER TO T-S. REPLACED SEAT 2AB O2 CONTAINER AND PERFORMED DROP TEST. SEATS 6ABC, 12ABC, 18ABC, 19ABC, 21ABC, 25ABC, 3DEF, 6DEF, 8DEF, 24DEF, AND 26DEF WOULSDR UALA2010101903863Liner · crackedNR 2 ENGINE INLET ATTRITION LINER HAS A 3 INCH CRACK AT 6:00 POSITION. MEASURED AND FOUND DAMAGE ATTRITION LINER LOWER OB PANEL TOTAL DAMAGE IS 26.81%. STARTED ATTRITION LINER REPAIR PER MT 72-017. DAMAGE REMOVED AND INSTALLED FILLER MATERIAL AT 14:00. NEEDS SDR UALA2010100103631Slide · reads lowDOOR 1R SLIDE PRESSURE LOW. REPLACED NR 1R DOOR SLIDE ASSY.SDR UALA2010091003351Controller · malfunctionedRT PACK OVERHEAT. RTFL DUE TO OVERHEAT FAULTS ON RIGHT PACK NEED TO REPLACE 10HA2. REPLACED 10HA2 BLEED PRESSURE REGULATOR VALVE SOLENOID. REPLACED EXHAUST OUTLET DOOR ASSY AND DOOR ACTUATOR (P/N 762A0000-04), OPS CHECKED GOOD, PACK TEMP CONTROL SYSTEM TESTSDR UALA2010080902895Tire · blownTIRES BLOWN DURING T/O ROLL. ABORTED TAKEOFF, 2 TIRES BLOWN AND 2 TIRES AIR DEPLETED FROM TIRE. REFERENCE NR 1 AND 2 TIRES BLOWN, NR 3 AND 4 TIRES ALL AIR DEPLETED. REPLACED ALL 4 TIRES PER MM. REPLACED ALL 4 BRAKES.SDR UALA2010072602680Control Panel · faultyCREW REPORTS THE CABIN EMERGENCY EXIT LIGHTS WILL NOT TURN OFF. ACP OP CHECKS IAW AMM AND TSM. FOUND AFT FLT ATTEND PANEL EMER SW STICKING. NEEDS NEW AFT ATTND PNL. FOUND SW AT AFT FLT ATTND PANEL DEFECTIVE. RPLD AFT FLT ATTND PANEL AND NO FURTHER DEFECTS NOTSDR UALA2010030800799Connector · inoperative1A AND 1B EMERGENCY SEAT LIGHTS INOPERATIVE. SECURED SEAT CONNECTOR, LIGHTS CHECKED OKAY.SDR UALA2010021100524Skin · damagedLT WING PANEL 540 PB WING SKIN BOLT HOLES HAS GOUGES. REPAIRED REF MAE EA 520-57 21-13-A1927 AND UAL EVA.SDR UALA2010021100525Skin · gougedPANEL 540PB, WING SKIN BOLT HOLES HAS GOUGES. INSTALLED REPAIR REF MAE EA320-5721-13-A1927 AND EVA.SDR UALA2010020500458Stringer · corrodedAFT PIT BILGE STRINGER 43L CORRODED BETWEEN FRAMES C-56 & C-57. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION & FOUND BLEND OUT OF LIMITS. CUT-OUT DAMAGE. FABRICATED & INSTALLED FILLER & COUPLING REPAIR. RESTORED FINISH.SDR UALA2009121403857Wire · brokenNR 1 ENG FIRE BOTTLE WILL NOT TEST. SQUIB CHANGE DID NOT CORRECT, ENG FIRE CONTROL PANEL ON UAX 6339 ETA 1801. PANEL DID NOT FIX, NEW SQUIB ETA 2352. ASKED FOR AET TO EFS. FOUND WIRE CF20 AT SQUIB CONNECTOR 5WE1 BROKEN. ACCOMPLISHED ENVIRONMENTAL SPLICE REPASDR UALA2009042401186Hose · unserviceableHYDROSTATIC HOSE DAMAGED. UNKNOWN POSSIBLE MANUFACTURING DEFECT. REPLACED HYDROSTATIC HOSE WITH A NEW ONE.SDR UALA2009042101160Skin · damagedREMOVE TWO (2) AFA25-0063-1 ANTENNAS, FROM THE LOWER SKIN, AT APPROX STA 1185. MAJOR REPAIR ACCOMPLISHED. REMOVED ANTENNAS AND INSTALLED DOUBLERS PER DE-TED JC 4C0708148.SDR 2008UALA05744Valve · malfunctionedTRIM & FUEL BALANCE PROBLEM. FLIGHT DIVERTED. FOUND AIR RELEASE VALVE AT FAULT. PERFORMED SEVERAL FUEL TRANSFER CHECKS, CHECKED ALL FLIGHT CONTROL ROD ENDS, REPLACED AIR RELEASE VALVE, ALL TESTS CAME BACK NORMAL.SDR 2008UALA03907Bearing · wornDIVERTED TO JAX DUE TO AN EXTREME VIBRATION. REPLACED ALL RUDDER HINGE BEARINGS AND ALL ELEV HINGE BEARINGS. TEST FLIGHT NORMAL, NO VIBRATION NOTED.SDR 2008UALA02858Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM ITEM 175. ACCOMPLISHED MAJOR REPAIR AT DEN. INSTALLED FLOORBEAM. REQUIRES INSTALLATION OF WIRE CLAMPS AND BLOWER FAN BOLTS. HARDWARE IS ATTACHED TO FLOORBEAM.SDR 2008UALA02857Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM ITEM 210. ACCOMPLISHED MAJOR REPAIR AT DEN. REMOVED FLOORBEAM, FLOOR BEAM INSTALLED. NEED TO SECURE AFT OUTBOARD BOLT, AND WIRE CLAMPS.SDR 2008UALA02812Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM 205. MAJOR REPAIR ACCOMPLISHED: REPLACED BEAM.SDR 2008UALA02811Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM 200. MAJOR REPAIR ACCOMPLISHED: REPLACED BEAM.SDR 2008UALA02838Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM ITEM 235. MAJOR REPAIR ACCOMPLISHED, REPLACED FLOORBEAM 235.SDR 2008UALA02814Floorbeam · corrodedFOUND CORROSION ON FLOOR BEAM NR 215.
SDR 2008UALA02813Shear Plate · corrodedFOUND SHEAR PLATE NR 15 CORRODED.SDR 2008UALA02798Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM NR 165. MAJOR REPAIR ACCOMPLISHED: REPLACED BEAM.SDR 2008UALA02797Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM NR 250.
SDR 2008UALA02794Sill · corrodedDOOR SILL 2R CORRODED AROUND FLOOR PANEL ATTACH NUTPLATE HOLES IN AREA OF FR66.SDR 2008UALA02793Floorbeam · corrodedCORROSION FOUND ON FLOORBEAM NR 255.SDR 2008UALA02796Beam · corrodedLT AFT PASSENGER-CREW DOOR SILL BEAM HAS CORROSION AROUND FLOOR PANEL ATTACH NUTPLATE HOLE LOCATED AT INBD MOST FLANGE APPROX 4 INCHES FWD OF FR68. MAJOR REPAIR ACCOMPLISHED: MFG AND INSTALLED ANGLE REPAIR WET.SDR 2008UALA02402Oxygen Mask · leakingSUSPECT O2 LEAK CAPTOR 1ST OBS MASK FITTING. FOUND 2ND OBS. MASK DISCONNECTED. SUSPECT LEAK FROM THERE. CONNECTED MASK AND CHECKED FITTINGS FOR LEAKS, NONE NOTED, SERVICED CREW O2 TO FULL.
SDR 2008UALA02056Cover · missingEMERGENCY EXIT ROW LIGHT COVER MISSING AT MID CABIN, ROW SIDE ABC. REPLACED LENS COVER.
SDR 2008UALA01679Oxygen System · reads lowCREW O2 IS LOW (1430PSI) FOUND ON 3SVC. SUPPLEMENTAL DATA UPDATE CAUSE, UNKNOWN. SERVICED CREW O2, LEAK CHECK OK.SDR 2008UALA01042Accumulator · lowR1 DOOR ACCUM PRESS NEEDS SERVICING. SERVICED TO FULL, NO LEAKS NOTED.SDR 2008UALA00547Cylinder · lowDOOR ASSIST ACCUMULATOR AT 2L NEEDS SERVICING. SERVICED DOOR ASSIST CYLINDER AT DOOR 2L. NO REPEATS SINCE ORIGINAL.SDR 2008UALA00546Cylinder · lowDOOR ASSIST ACCUMULATOR AT 1R NEEDS SERVICING. SERVICED DOOR ASSIST CYLINDER AT DOOR 1R. NO REPEATS SINCE ORIGINAL.SDR 2008UALA00152Bottle · low pressureDOOR 2L ASSIST BOTTLE PRESSURE READS 7.0 PSI. SHOULD READ APPROX 1740 PSI. SERVICED DOOR ASSIST BOTTLE TO CORRECT PRESSURE.SDR 2007UALA04355Unknown · vibrationVERY ROUGH VIBRATION. PRONOUNCED FLUTTERING FELT LIKE COMING FROM TAIL DURING CLIMB FROM 18000. MAINT TEXT: CREW STATES VIBRATION FELT ALL FLT LEVELS AT HIGH SPEED SLOWING 30KNTS VIBRATION LESS NOTICEABLE. REPLACED RT ELEVATOR SERVO CONTROL 34CE2. FOLLOWSDR 2007UALA02180Unknown · vibrationENCOUNTERED HIGH SPEED BUFFET AT FL260 AT 320 KNOTS. FLT ATTENDANT REPORTED UP & DOWN MOTION WORST IN AFT CABIN. *S/D* COMPLETED ELEVATOR PLAY CHECKS- ALL GOOD - RIGGED ELEV 5 DEG NOSE DOWN. NO REPEATS SINCE 21 JUNE.SDR 2007UALA01506Relay · inoperativeON CARGO SMOKE TEST AGENT 2 DISCHARGE LIGHT DOES NOT ILLUMINATE. [06-29-07] FAULT TRACED TO A FAULTY RELAY. REPLACED 17WX DISCHARGE 2 LIGHT RELAY.SDR 2007UALA01167Wire · brokenCABIN EMERGENCY LIGHTS FAIL 3SVC CK. EPSU COMM FWD LEFT DISPLAYED. SUPPLEMENTAL DATA UPDATE, FOUND WIRE PULLED OUT OF SOCKET ON CONNECTOR AT 10WL PSU ABOVE DOOR 1L, CEILING PANEL REMOVED FOR ACCESS AND CONNECTOR REMOVED. CHECKED OK.SDR 2007UALA00876Connector · disconnectedINVESTIGATING SMC 003 FAULT. FOUND BOTH THE LEFT AND RIGHT OVERWING EMERGENCY EXIT EPSU UNIT CONNECTOR DISCONNECTED. [SUP 06-01-07] ALL EMERGENCY POWER SUPPLY UNITS WERE CHANGED DURING A REGULARLY SCHEDULED HMV VISIT 2 WEEKS PRIOR. STATION PERFORMING HMV DISDR 2007UALA00786Unknown · vibrationHIGH FREQUENCY VIBRATION STARTED 23,500- 330 KNOTS WENT AWAY 24,500-300 KNOTS RETURNED AGAIN 25,000-315 KNOTS AND STOPPED 30,500-290 KNOTS .76 MACH. VIBRATION VERY NOTICEABLE THROUGHOUT CABIN. FLT CONTROLS SEEMED OK. CREW REPORTED UP & DOWN OSCILLATION THRSDR 2006UALA01898Skin · dentedUPPER PYLON SKIN AT NR 1 ENG BETWEEN RIB 04 AND 06 JUST FWD OF STA 495 HAS DENTS IN SKIN. AIRBUS TEAM REPLACED CANTILEVER BEAM IN ACCORDANCE WITH REPORT M-300903-EMBOD. "DAMAGE ON THE LT PYLON CANTILEVER WAS FOUND DUE TO EQUIPMENT FAILURE DURING ENGINE CHSDR 2006UALA01047Warning System · activatedGEAR UPLOCK FAULT DISPLAYED ON FINAL. REPLACED RIGHT MAIN GEAR DOOR ACTUATOR. ACCOMPLISHED NORMAL AND ALTERNATE EXTENSION OF GEAR. OPS CHECKED NORMAL.SDR 2006UALA00975Skin · buckledEXTERNAL FUSELAGE SKIN BUCKLED SURROUNDING JACK PAD AREA APPROX FRAME 71 THRU FRAME 76, BETWEEN STR 31L THRU STR 31R. REPAIR WAS ACCOMPLISHED BY AIRBUS ON WORK ORDER M-300742-EMBOD.SDR 2006UALA00510Connector · looseFLOOR EEL LIGHT INOP AT SEAT 1A. FOUND UNDER SEAT CONNECTOR DISCONNECTED. RESECURED UNDER SEAT CONNECTOR AND OPS CHECKED NORMAL.SDR 2005UALA00569Engine · stalledNR 2 ENGINE OVERTEMPTED & STALLED ON TAKEOFF. ENGINE WAS REPLACED AND AIRCRAFT CONTINUED FUTHER FLYING WITHOUT INCIDENT. THE ENGINE FAILURE WAS CONFIRMED AS A HIGH PRESSURE COMPRESSOR 3RD STAGE BLADE (R3 BLADE) FAILURE. THIS IS AN INDUSTRY-WIDE AND KNOWN ISDR 2005UALA00412O-Ring · failedYELLOW RESERVOIR LOW LEVEL FAILURE WITH BLUE SYS LOW AND GREEN FLUCTUATING AS WELL. FLIGHT LANDED WITHOUT INCIDENT. REPLACED B-NUT AND O-RING ON PTU MANIFOLD REF MM 29-13-15-991-001 PTU MANIFOLD ITEM 5 AND 52 LEAK CHECK OK. FOUND BAD O-RING SOURCE OF LEAK. SSDR 2004UALA00718Cover · dislodgedEVAC SLIDE ON DR2L COVER WILL NOT STAY ON. THE FWD RETAINING HOLE IN THE IN THE SLIDE FIBERGLASS PACKBOARD WAS DAMAGED. THE PROBABLE CAUSE FOR THE PACKBOARD HOLE GETTING DAMAGED IS IN-SERVICE IMPACT BY FOREIGN OBJECTS, SUCH AS SERVICE CARTS OR PERSONNEL/PASSSDR 2003UALA00933Battery Pack · dischargedEMERGENCY LIGHT TEST FAILS. REPLACED BATTERY PACK 10WL.
Back to N446UA