N450UP

Service difficulty reports · 116

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N450UP' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR IPXA1569395Floor Support · crackedINSPECTION TYPE:C1, MAIN DECK FLOOR SUPPORT CRACKED, BS 483 RBL 54, WL 208, MARKED. REPLACED IAW SRM.Sep 6, 2011 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1569394Floor Support · crackedINSPECTION TYPE:C1, CRACKED FLOOR SUPPORT BS 840 TO BS 860, LBL 16, WL 208. REPLACED IAW SRM.Sep 6, 2011 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1569379Seat Track · corrodedINSPECTION TYPE:C1, CORROSION ON MAIN CARGO SEAT TRACK INBD FLANGE BS 1008-1018, RBL 60, WL 208. REPAIRED IAW ATS ER 11-04426.Sep 6, 2011 · N450UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1569369Doubler · chafedRIGHT AFT FAIRING STRUCTURE, RT FWD MACHINED DOUBLER IS CHAFED AND WORN AT PPS 208, PN 313N5025-1. R & R DOUBLER IAW DWG 313N5025, REV F AND SRM 51-40-02-0G.Sep 6, 2011 · N450UP · Boeing 75724APF · Nacelle/Pylon Miscellaneous StructureSDR IPXA1569336Bracket · wornRIGHT AFT FAIRING STRUCTURE, RT FWD CHANNEL BRACKET BUSHING HOLES ARE WORN AND DAMAGED AT PPS 209, PP RBL 6.26 P/N 313N5033-91. REMOVED, FABRICATED AND INSTALLED RT FWD CHANNEL BRACKET IAW SRM 51-40-02-0G.Sep 6, 2011 · N450UP · Boeing 75724APF · Nacelle/Pylon Miscellaneous StructureSDR IPXA11569276Angle · gougedINSPECTION TYPE: MOD RT AFT FAIRING STRUCTURE, RT FWD VERTICAL ANGLE IS GOUGED IN RADIUS AT PPS 208. R & R ANGLE IAW SRM 51-40-02-0G, SRM 51-40-06-0G, SRM 51-40-08-0G AND DWG 313N5033.Sep 6, 2011 · N450UP · Boeing 75724APF · Nacelle/Pylon Miscellaneous StructureSDR IPXA1569587Frame · damagedC1 CHECK, SCREW START MARK ON INNER FLANGE OF FRAME, BS 1400 BETWEEN 25L-26L. REPAIRED IAW SRM 53-00-07-2R5 AND ATS ER 11-04537.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA1569575Frame · dentedC1 CHECK, BULK CARGO, INNER FLANGE OF FRAME DENTED BS 1540, BETWEEN STR 26L- 27L. REPAIRED IAW ER 11-04597.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA1569530Frame · dentedINSPECTION TYPE:C1, BULK CARGO, INNER FLANGE OF FRAME DENTED BS 1520, STR 26L. REPAIRED IAW SRM 53-00-07-2R5 AND ATS ER 11-04539.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA1569518Frame · dentedINSPECTION TYPE:C1, BULK CARGO, INNER FLANGE OF FRAME DENTED BS 1620 BETWEEN STR 25L- 26L. REPAIRED IAW SRM 53-00-07-2R 5 AND ER 11-04536.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA1569492Support Angle · gougedINSPECTION TYPE:C1, STROBE LIGHT POWER SUPPLY INBD SUPPORT ANGLE HAS GOUGE ON UPPER SURFACE AT FWD END, LOCATED UNDER PANEL 544BB AT WSTA 820. REPLACED IAW DWG 284N1113, DWG 284N1120, SRM 51-30-01-0G, SRM 51-40-05-0G, SRM 51-40-06-0G, SRM 51-40-02-0G, ATS ER Sep 5, 2011 · N450UP · Boeing 75724APF · Wing Miscellaneous StructureSDR IPXA1569491Support Angle · gougedINSPECTION TYPE: C1, STROBE LIGHT POWER SUPPLY OTBD SUPPORT ANGLE HAS GOUGE ON UPPER SURFACE FWD END, LOCATED UNDER PANEL 544 BB AT WSTA 829. REPLACED IAW DWG 284N1113, DWG 284N1120, SRM 51-30-01-0G, SRM 51-40-05-0G, SRM 51-40-06-0G, SRM 51-40-02-0G, ATS ER 1Sep 5, 2011 · N450UP · Boeing 75724APF · Wing Miscellaneous StructureSDR IPXA1569489Frame · dentedINSPECTION TYPE:C1, BULK CARGO, INNER FLANGE OF FRAME DENTED BS 1520 BETWEEN STR 25R- 26R. REPAIRED IAW SRM 53-00-07-2R5 AND ATS ER 11-04540.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA1569488Frame · dentedINSP TYPE:C1, BULK CARGO INNER FLANGE OF FRAME DENTED BS 1500 BETWEEN STR 20R-21R. REPAIRED IAW ER 11-04538.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA11569442Seat Track · corrodedINSPECTION TYPE:C1, MAIN DECK SEAT TRACK HAS CORROSION AT SEVERAL AREAS, BS 345-440, BOTH FLANGES, LBL 46. REPLACE IAW DWG 141N5130 AND SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-40-08-0G.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA1569381Floor Support · corrodedINSPECTION TYPE:C1, COCKPIT LT FLOOR SUPPORT CHANNEL HAS CORROSION AT SEVERAL AREAS, BS 312-323, LBL 57. REMOVED, FABRICATED, DRILLED, APPLIED FINISH AND INSTALLED IAW SRM51-40-02, SRM 51-40-05, SRM 51-40-08, AMM 51-21-04-7.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1569334Floorboard · damagedINSPECTION TYPE:C1, MAIN DECK FLOORBOARD HAS MINOR EDGE DAMAGE, BS 340-BS 440, BL 0, LBL 25. FABRICATED NEW FLOORBOARD IAW SRM 53-00-50-1A-1 AND EO B757-5320-9692-G.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA20110905001Frame · dentedINSPECTION TYPE: C1, BULK CARGO, INNER FLANGE OF FRAME DENTED BS 1480 BETWEEN 26R SRM 53-00-07-2R-5 DETAIL ISep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA11569275Floorboard · damagedINSPECTION TYPE:C1, MAIN DECK FLOORBOARD HAS MINOR EDGE DAMAGE, BS 340-440, RBL 45-60. FABRICATED REPLACEMENT FLOORBOARD IAW SRM 53-00-50-01I 1 AND EO.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11569274Floorboard · damagedINSPECTION TYPE:C1, MAIN DECK FLOORBOARD HAS MINOR EDGE DAMAGE, BS 340-BS 440 RBL 25-RBL 45. FABRICATED REPLACEMENT FLOORBOARD IAW SRM 53-00-50-0I 1 AND EO.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11569273Floorboard · damagedINSPECTION TYPE: C1, MAIN DECK FLOORBOARD HAS MINOR EDGE DAMAGE, BS 340-BS 440 RBL 0 - RBL 23. FABRICATED REPLACEMENT FLOORBOARD IAW SRM 53-00-05-0I 1 AND EO.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11569272Floor Panel · damagedINSPECTION TYPE:C1, MAIN DECK FLOORBOARD HAS MINOR EDGE DAMAGE BS 340-440, LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM 53-00-50-0I 1 AND EO.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11569271Floor Panel · damagedINSPECTION TYPE: C1, MAIN DECK FLOORBOARD HAS MINOR EDGE DAMAGE, BS 340-440, LBL 25-45. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM 53-00-0I 1 AND EO.Sep 5, 2011 · N450UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA1569490Frame · damagedINSPECTION TYPE:C1, SCREW STRIKE ON INBD FACE OF FRAME INBD FLANGE BS 1640 BETWEEN STR 15L AND 16L. REPAIRED IAW ATS ER 11-04428.Sep 4, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA1569468Frame · gougedINSPECTION TYPE: C1, 2 SCREW STRIKES ON INBD FACE OF FRAME INBD FLANGE BS 1300 BETWEEN STR 15L AND STR 16L. REPAIR IAW ATS ER 11-04410, DATED 23-SEP-2011 AND B757-5310-44298-A DATED 26-SEP-2011.Sep 4, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA1569396Frame · damagedINSPECTION TYPE:C1, SCREW STRIKE ON INBD FACE OF FRAME, INBD FLANGE, BS 1580 AT STR 14R. REPAIRED SCREW STRIKE IAW ER 11-04501.Sep 4, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA1569335Structure · corrodedINSPECTION TYPE:C1, FUSELAGE SECTION 48, INTERIOR STABILIZER CENTER SECTION COMPARTMENT RT, RAM AIR DOOR SURROUND STRUCTURE AT BS 1792, STR 6R, FWD OTBD CORNER HAS (4) NUTPLATES WITH CORROSION. REPLACED STRAP IAW SRM 51-40-02-0G.Sep 4, 2011 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA11569155Attach Bracket · damagedLEFT AFT FAIRING STRUCTURE, AFT UPPER DRAIN TUBE LOOSE AT THE ATTACHING BRACKET. REQUIRES REPLACEMENT OF THE BRACKET. REPLACED BRACKET IAW SRM 51-40-02-0G, SRM 51-40-05-0G, SRM 51-40-06-0G, AND DWG 313N5042.Sep 4, 2011 · N450UP · Boeing 75724APF · Nacelle/Pylon, Attach FittingsSDR IPXA1569501Frame · damagedINSPECTION TYPE: C1, SCREW STRIKE ON INBD FACE OF FRAME INBD FLANGE BS 365.25 BETWEEN STR 15L AND STR 16L. REPAIRED IAW ATS ER 11-04422.Sep 3, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA11569459Intercostal · gougedINSPECTION TYPE:C1, INTERCOSTAL WEB HAS GOUGE ON EDGE OF INBD VERTICAL FLANGE, BS 595, STR 15R. REPAIRED IAW ATS ER 11-04472.Sep 3, 2011 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA1569393Frame · gougedINSPECTION TYPE:C1, SCREW STRIKE ON INBD FACE OF FRAME, INBD FLANGE, BS 1100 BETWEEN STR 15R AND STR 16R. REPAIRED IAW ER 11-04494 AND SRM 51-20-01-0G.Sep 3, 2011 · N450UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA1569337Channel · chafedNR 1 PYLON UNDERWING FAIRING, FWD UPPER CHANNEL ASSY HAS NUMEROUS WORN AND CHAFING AREAS, AND THE INBD SIDE HAS PULLED FASTENERS, PN 313N5004-89. R & R WORN CHANNEL ASSY IAW SRM 51-40-05-0G, SRM 51-40-02-0G AND DWG 313N5004.Sep 3, 2011 · N450UP · Boeing 75724APF · Nacelle/Pylon Miscellaneous StructureSDR IPXA1569330Stringer Clip · bentINSPECTION TYPE:C1, BENT STRINGER CLIP, BS 333, STR12L. FABRICATED REPLACEMENT STRINGER CLIP, HEAT TREATED, REFINISHED AND INSTALLED IAW SRM 51-30-01, SRM 51-40-05, SRM 51-40-02, AND DWG 453N1331.Sep 3, 2011 · N450UP · Boeing 75724APF · Fuselage Main, Attach FittingsSDR IPXA1569487Floor Panel · corrodedINSPECTION TYPE:C1 COCKPIT FLOOR HAS CORROSION BS 292, LBL 44. REPAIRED IAW ATS ER 11-04414, DATE 27-SEP-2011 AND EO B757-5310-44275-A, DATED 28-SEP-2011.Sep 2, 2011 · N450UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA11569441Filler · corrodedINSPECTION TYPE:C1, CORROSION ON NR 1 ENG PYLON 3" ABOVE AFT LOWER CORNER OF CUTOUT FOR PANEL 433CL. REMOVED FABRICATED AND INSTALLED NEW FILLER IAW SRM 51-10-02-0G, SRM 51-40-02-0G SRM 51-40-08-0G DWG 311N5002.Sep 2, 2011 · N450UP · Boeing 75724APF · Nacelle/Pylon, Main FrameSDR IPXA09557340Support · crackedINSPECTION TYPE:C4 AFT CARGO BAY, EXISTING REPAIR ON FLOOR TO SIDEWALL SUPPORT PLATE INSTALLED WITH BLIND FASTENERS, AND DAMAGE EXTENDS BEYOND REPAIR (CRACKED) BS 1230, RBL 20. REPAIRED SIDE PANEL (FLOOR TO SIDEWALL SUPPORT) PER SRM 51-70-11-0G.Sep 4, 2009 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA09557343Sill · corrodedINSPECTION TYPE:C4 FWD CARGO COMPARTMENT DOOR CUTOUT LOWER SILL UPPER SURFACE IS CORRODED NEAR NUT PLATE BS 596. REPLACED LWR SEAL RETAINER SUPPORT ANGLE.Sep 2, 2009 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA09557289Panel · corrodedINSPECTION TYPE:C4 CORROSION ON SIDE PANEL, BS 1377 TO 1452, RBL 19-21, WL 156. REMOVED AND REPLACED SIDE PANEL PER SRM 51-40-02-0G.Sep 2, 2009 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA09557288Attach Angle · corrodedINSPECTION TYPE:C4 FWD CARGO DOOR CUTOUT, AFT CENTER TIEDOWN ATTACH ANGLE IS CORRODED BS 600. REMOVED, FABRICATED, AND INSTALLED ANGLE PER DWG 69-47626, AND SRM 51-40-02-0G.Sep 2, 2009 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA09557352Skin · damagedINSPECTION TYPE:C4 RT ELEVATOR TRAILING EDGE OUTBOARD TIP AFT FACE HAS DAMAGED CARBON FIBER CORE APPROX 2 INCHES INBOARD 1 INCH LONG. REPAIRED PER SRM 51-70-04-0G.Sep 1, 2009 · N450UP · Boeing 75724APF · Elevator, Plate/SkinSDR IPXA09557346Skin · damagedINSPECTION TYPE:C4 RT ELEVATOR TRAILING EDGE O/B END LOWER SKIN HAS DAMAGED SKIN. REPAIRED PER SRM 51-70-04-0G-0.Sep 1, 2009 · N450UP · Boeing 75724APF · Elevator, Plate/SkinSDR IPXA09557342Skin · chafedINSPECTION TYPE:C4 RT WING INBOARD FLAP UPPER SURFACE IS CHAFED AFT OF FIXED T/E PANEL. REPAIRED PER SRM 51-70-07.Sep 1, 2009 · N450UP · Boeing 75724APF · Trailing Edge FlapsSDR IPXA09557394Seat Track · corrodedINSPECTION TYPE:C CORROSION ON NUT PLATE ATTACH FASTENERS ON MCB SEAT TRACK BS 1184, RBL 60, WL 208. REPAIRED MCB SEAT TRACK IAW ER NO 09-4388.Aug 31, 2009 · N450UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA09557379Panel · misrepairedINSPECTION TYPE:C4 PREVIOUS REPAIRS TO VERTICAL STAB PANEL 322CL REQUIRE REWORK DUE TO INFORMATION REQUESTED BY ENGINEERING. REPAIRED PER SRM 51-70-17-0G AND UPS EO B757-5530-34918-A.Aug 31, 2009 · N450UP · Boeing 75724APF · Vertical Stabilizer Miscellaneous StructureSDR IPXA09557377Panel · misrepairedINSPECTION TYPE:C4 PREVIOUS REPAIRS TO VERTICAL STAB PANEL 322CL REQUIRE REWORK DUE TO INFORMATION REQUESTED BY ENGINEERING. REPAIRED PER SRM 51-70-17-0G AND UPS EO B757-5530-34918-A.Aug 31, 2009 · N450UP · Boeing 75724APF · Vertical Stabilizer Miscellaneous StructureSDR IPXA09557372Web · puncturedINSPECTION TYPE:C4 NR 1 ENGINE INBOARD UPPER WEB FOR TRANSLATING SLEEVE IS PUNCTURED (MARKED). REPAIRED SEAL SUPPORT WEB IAW AMM 78-31-20-8.Aug 31, 2009 · N450UP · Boeing 75724APF · Engine Thrust ReverserSDR IPXA09557287Floor Support · corrodedINSPECTION TYPE:C4 CORROSION ON FLOOR SUPPORT BS 1060, LBL 41 TO LBL 37, WL 208. REMOVED, FABRICATED, AND INSTALLED FLOOR SUPPORT PER DWG 144N5005-3 AND SRM 51-40-02-0G.Aug 31, 2009 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA09557286Floor Support · corrodedINSPECTION TYPE:C4 CORROSION ON FLOOR SUPPORT BS 1056, LBL 48 TO LBL 58, WL 208. REMOVED FABRICATED AND INSTALLED FLOOR SUPPORT PER DW 144N5005-7, AND SRM 51-40-02-0G.Aug 31, 2009 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA09557285Floor Support · corrodedINSPECTION TYPE:C4 CORROSION ON FLOOR SUPPORT, BS 1020, RBL 3 TO RBL 22, WL 208. REMOVED, FABRICATED AND INSTALLED FLOOR SUPPORT PER DWG 1144N5005-2 AND SRM 51-40-02-0G.Aug 31, 2009 · N450UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA09557284Floor Support · corrodedINSPECTION TYPE:C4 CORROSION ON FLOOR SUPPORT BS 900, LBL 3 TO LBL 20, WL 208. REMOVED FABRICATED AND INSTALLED FLOOR SUPPORT PER DWG 144N5005-2 AND SRM 51-40-02-0G.Aug 31, 2009 · N450UP · Boeing 75724APF · Fuselage Miscellaneous Structure
Back to N450UP