What was found
INSPECTION TYPE:C1, MAIN DECK FLOORBOARD HAS MINOR EDGE DAMAGE BS 340-440, LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM 53-00-50-0I 1 AND EO.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1, MAIN DECK FLOORBOARD HAS MINOR EDGE DAMAGE BS 340-440, LBL 45-60. FABRICATED REPLACEMENT FLOOR PANEL IAW SRM 53-00-50-0I 1 AND EO.