N451UP
Service difficulty reports · 283
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N451UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N451UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2016040501716Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 232XSF DAMAGED. FABRICATED FLOOR PANEL 232XSF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016041202017Floor Panel · damagedINSPECTION TYPE:SEG3, MAIN CARGO FLOOR PANEL 252XUF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016041202016Floor Panel · damagedINSPECTION TYPE:SEG3, MAIN CARGO FLOOR PANEL 232XCF DAMAGED. FABRICATED AN NEW FLOOR PANE IAW SREO B757-5320-9692-H.SDR IPXA2016040701781Floor Panel · damagedINSPECTION TYPE:SEG3, MAIN CARGO FLOOR PANEL 222XAF DAMAGED. FABRICATED FLOOR PANEL IAW SREO BB757-5320-9692-H.SDR IPXA2016040501721Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 222XCF DAMAGED. FABRICATED FLOOR PANEL 222XCF FROM A402H-48X144 BATCH 2801694 IAW SREO 5320-9692-H.SDR IPXA2016040501719Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 221XAF DAMAGED. FABRICATED FLOOR PANEL 221XAF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040501715Floor Panel · damagedINSPECTION TYPE:SEG, MAIN CARGO FLOOR PANEL 221XCF DAMAGED. FABRICATED FLOOR PANEL 221XCF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040501712Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 232XBF DAMAGED FABRICATED FLOOR PANEL 232XBF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040501711Floor Panel · damagedINSPECTION TYPE:SEG 3, MAIN CARGO FLOOR PANEL 231XCF DAMAGED. FABRICATED FLOOR PANEL 231XCF FROM A402H-48X144 BATCH NR 2801694 IAW SREO 5320-9692-H.SDR IPXA2016040201518Floor Panel · damagedINSPECTION TYPE: SEG3, MAIN CARGO FLOOR PANEL 231XBF DAMAGED. FABRICATED FLOOR PANEL 231XBF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040201517Floor Panel · damagedINSPECTION TYPE: SEG3, MAIN CARGO FLOOR PANEL 231XAF DAMAGED. FABRICATED FLOOR PANEL 231XAF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040201519Floor Panel · damagedINSPECTION TYPE: SEG3, MAIN CARGO FLOOR PANEL 232XAF DAMAGED. FABRICATED FLOOR PANEL 232XAF FROM A402H-48X144, BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016040101486Floor Panel · damagedINSPECTION TYPE:SEG3, MAIN CARGO FLOOR PANEL 221XBF DAMAGED. FABRICATED FLOOR PANEL 221XBF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2015061790289Battery · dischargedFOUND CAPTAIN`S EVAS LID LOOSE AND BATTERY DEAD. NO TEST. CAPTAIN`S EVAS REMOVED IAW AMM 25-69-00 TESTED NORMALLY.SDR IPXA2014041682673Floorboard · gougedINSPECTION S2CP, UPPER CARGO FLOORBOARD 241XFF HAS GOUGE AND CORE DAMAGE. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2014582670Floor Panel · damagedINSPECTION S2CP, UPPER CARGO FLOOR PANEL 242XFF HAS EDGE DAMAGE AND SOFT CORE MATERIAL AND SOFT CORE MATERIAL. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014041682668Floorboard · damagedINSPECTION S2CP, UPPER CARGO FLOORBOARD 242XEF HAS EDGE DAMAGED AND SOFT CORE MATERIAL. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2014041682674Floor Panel · damagedINSPECTION S2CP, CABIN FLOOR PANEL 241XHF HAS EDGE DAMAGE, AND DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014042582762Skin · tornDURING S2CP INSPECTION, LEFT OTBD AFT FLAP HAS A TWO INCH TEAR IN UPPER SURFACE EIGHT INCHES OTBD OF INBD EDGE AND FOURTEEN INCHES FWD OF T/E. FOUND WITHIN LIMITS IAW SRM 57-53-01-2R-1,TABLE 11.2.SDR IPXA2014042182709Floor Panel · damagedDURING S2CP INSPECTION, FLOOR PANEL 241XCF HAS EDGE DAMAGE & DELAMINATION. FABRICATED NEW FLOOR PANEL IAW EO B757-5320, 9692-H.SDR IPXA2014041682676Floor Panel · damagedINSPECTION S2CP, FLOOR PANEL 241XGF HAS EDGE AND CORNER DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014041682675Floor Panel · damagedINSPECTION S2CP, FLOOR PANEL 241XDF HAS EDGE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014041682672Floor Panel · damagedINSPECTION S2CP, FLOOR PANEL 241XEF HAS EDGE, CORNER, HOLE DAMAGE. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2014041682671Floor Panel · damagedINSPECTION S2CP, FLOOR PANEL 241XHF HAS A MISSING INSERT. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2013120601019Lamp · inoperativeEMERGENCY LIGHT ASSY HAS FOUR LAMPS INOPERATIVE. R & R LAMPS IAW AMM 33-51-01-2.SDR IPXA2574684Flap System · malfunctionedL/E FLAP DISAGREE MESSAGE, ACCOMPLISHED L/E FLAP DISAGREE & L/E FLAP ASYM CHECKLIST. RETURNED TO DEPARTURE. TROUBLESHOT IAW FIM 27-81-00-815-803. COULD NOT DUPLICATE CAUSE OF TRIPPED PDU OVERLOAD INDICATOR. OPS CHECKED NORMAL IAW MM 27-81-00-715-001.SDR IPXA2573325Structure · dentedINSPECTION TYPE: C, MAIN CARGO DOOR BS 600-610 DENTED AT ACTUATOR ACCESS. REPAIRED IAW SRM 52-30-01-2R-4.SDR IPXA2573324Structure · dentedINSPECTION TYPE: C, MAIN CARGO DOOR BS 490-500 DENTED AT ACTUATOR ACCESS REPAIRED IAW SRM 52-30-01-2R-4.SDR IPXA2572793Slat System · malfunctionedL/E SLAT SYS EICAS MESSAGE "L/E SLAT DISAGREE" DISPLAYED WI TH THE FLAP LEVER IN 1. BOTH FLAP POINTERS INDICATE 1/2. IAW FIM 27-51-815-805, FSEU SHOWN NO PRESENT FAULTS. LAST FLIGHT FAULT SHOWS "SLAT DISAGREE" IN FSEU 1 AND 2. LT SLAT PDU OVERLOAD INDICATOR SDR IPXA0563647Bulb · inoperativeEMERGENCY LIGHT ASSY HAS 4 BULBS INOP. RELAMPED INOP BULBS IN EMERGENCY LIGHT ASSY IAW AMM 33-51-01-2.SDR IPXA0563606Gps · malfunctionedAFTER T/O REC'D FAULT GPWS ALERT INCLUDING TERR AND PULL UP ADVISORIES. CREW CONF FAULTY MESSAGE WHILE ENROUTE AND DETERMINED DATA WAS OK, BUT IRS DATA AND POS INFO WAS NOT OK. LT IRS AND FMC PPOS DISPLAYED CORRECT POSITION. GPWS OPS CK PERFORMED IAW AMM 34SDR IPXA10561723Flap System · malfunctionedAS FLAPS WERE IN TRANSIT FROM 1 TO UP SAW MOMENTARY INCREASE IN AIRSPEED TO 250 KNOTS. AFTER FLAPS UP AIRSPEED RAPIDLY DECREASED TO 235 KNOTS TS. FLAP INDICATOR WAS AT .5 POSITION. NR 431740 ASSIGNED. C/W PHASE 1 OVERSPEED INSP L/E FLAPS IAW AMM 05-51-08-2. SDR IPXA10561440Floor Panel · crackedINSP TYPE: SPV FLOOR PANEL 222XBF CRACKED. REPAIRED IAW EO B757-5320-9692G.SDR IPXA10559501O-Ring · leakingLOST HYD QUANTITY IN LT SYS IN FLIGHT, .21 REMAINING. PERFORMED AS AN EMERGENCY. R & R O-RING AT LT SYS PRESS TRANSMITTER, SERVICED RESERVOIR TO FULL, LEAK AND OPS CHECKED GOOD IAW MM 29-31-01-4.SDR IPXA10559385Web · corrodedINSPECTION TYPE:C4 DUE TO RCD PROCESS COCKPIT FLOOR CORROSION BLENDS REQUIRES SEPARATE NRC FOR REPAIR RE-ENFORCEMENT DOUBLERS, THIS NRC IS FOR BS 239-271, RBL 10 TO RBL 16 FOR ATS ER 10-2221. REPAIR PER ATS ER 10-2221.SDR IPXA10559356Floorbeam · corrodedINSPECTION TYPE:C4 WHILE WORKING CUST CARD 849615 FOUND CORROSION ON FLOORBEAM LWR SURFACE AT NUT PLATE HOLE BS 1681 LBL 19-21, WL 208. REPAIR PER ATS ER 10-2302 UPS EO B757-5310-37439-A.SDR IPXA10559122Floor Panel · crackedINSPECTION TYPE:C4, WHILE WORKING CUST CARD NR 849024, FOUND MAIN CARGO BAY FLOOR PANEL CRACKED AND HAS EXPOSED HONEYCOMB ON UPPER SURFACE BS 560 TO BS 620, RBL 25 TO BL 0, WL 208.1. PANEL WAS REPLACED IAW EO B757-5320-9692-G.SDR IPXA10559354Floorbeam · corrodedINSPECTION TYPE:C4 WHILE WORKING CUSTOMER CARD 849334, FOUND CORROSION ON UPPER AND LOWER SURFACES OF FWD FLANGE OF UPPER CHORD, 1680 FLOORBEAM AT RBL 12.75. REPAIRED PER ATS ER 10-2302 UPS EO B757-5310-37439-A.SDR IPXA10559355Floorbeam · corrodedINSPECTION TYPE:C4 WHILE WORKING REPAIR OF WEB FOUND CORROSION ON UPPER AND LWR SURFACE OF FLOOR PANEL ATTACH NUT PLATE HOLE THRU BS 1681 FLOORBEAM, LBL 31, WL 208. REPAIR PER ATS ER 10-2302 UPS EO B757-5310-37439-A.SDR IPXA10559062Floor Support · corrodedINSPECTION TYPE:C4, LONGITUDINAL BEAM BS 1040 TO 1080 LBL 25, WL 208, HAS CORROSION ON FLANGES. REMOVED, FABRICATED AND INSTALLED NEW LONGITUDINAL BEAM IAW SRM 53-00-51-1A, SRM 51-40-02, SRM 51-40-05-0G.SDR IPXA10558993Seat Track · corrodedINSP TYPE:C4, SEAT TRACK HAS CORRODED NUTPLATES AT RBL 45 STA 1080 - STA 1180. R & R SEAT TRACK IAW SRM 51-40-02-0G.SDR IPXA10559029Strap · corrodedINSPECTION TYPE: C4, VERTICAL STAB FAIRING 326B HAS CORROSION ON INNER SURFACE STRAP. REMOVED, FABRICATED AND INATALLED REPLACEMENT STRAP IAW SRM 51-40-02.SDR IPXA10559573Floorboard · corrodedFLOORBOARD HAS DAMAGED AND CORRODED INSERTS AT AFT END OF BS 1600- 1680 RBL 0-25. REPLACED FLOORBOARD IAW EO B757-5100-33281B AND B757-5320-9692.SDR IPXA10559572Floorboard · corrodedFLOORBOARD HAS DAMAGED AND CORRODED INSERTS AT FWD END AT BS 1600-1680 RBL 45-65. REPLACED FLOORBOARD IAW EO B757-5100-33281B AND B757-5320-9692.SDR IPXA10559571Floorboard · corrodedFLOORBOARD HAS DAMAGED AND CORRODED INSERTS AT FWD END OF BS 1600-1680 RBL 25-45. REPLACED FLOORBOARD IAW EO B757-5100-33281B AND B757-5320-9692.SDR IPXA10559570Floorboard · corrodedFLOORBOARD HAS DAMAGED AND CORRODED INSERTS AT FWD END BS 1540- 1600 RBL 25-45. REP LACED FLOORBOARD IAW EO B757-5100-33281B AND B757-5320-9692.SDR IPXA10559291Seat Track · corrodedINSPECTION TYPE:C4, FUSELAGE FLOOR STRUCTURE SEAT TRACK NUT PLATES CORRODED AT LBL 25 BETW BETWEEN STA 1032 AND 1078. REPAIRED CORRODED FLOORBEAM UPPER CHORD IAW ER NR 10-2226, SRM 51-20-01-0G, AND SRM 51-10-02-0G.SDR IPXA10559290Frame · gougedINSPECTION TYPE:C4, BS395 FRAME IS GOUGED BETWEEN STR16L AND STR15L REPAIRED GOUGED BS395 FRAME IAW EO B757-5310-37397-A.SDR IPXA10559266Floorboard · damagedINSPECTION TYPE:C4, CABIN FLOORBOARD BS 1068-1720 LBL 0 TO 50 SEVERAL MISSING/DAMAGED INSERTS. REPLACED FLOORBOARD IAW EO B757-5320-9692GSDR IPXA10559224Floorbeam · corrodedINSPECTION TYPE:C4, FUSE UPPER LOBE, BS 1200 FLOORBEAM, UPPER CHORD, FWD AND AFT FLANGES ARE CORRODED AROUND FLOORBOARD HOLES, LBL 65 TO RBL 65 REPAIRED IAW ATS ER 10-2223
Back to N451UP