N452UP
Service difficulty reports · 230
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N452UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N452UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2021110875752Floor Panel · damagedINSPECTION TYPE:SEGPNL 241XJF DAMAGEDFABBED PANEL PER SREO B757-5320-9692-KSDR IPXA2021110875751Floor Panel · damagedINSPECTION TYPE:SEGPNL 242XLF DAMAGEDFABBED PANEL PER SREO B757-5320-9692-KSDR IPXA2021090373491Warning Message · false activationINSPECTION TYPE:N/A**DIVERSION*NO EMERG*A/C LANDED W/O INCIDENT*DURING FLAP RETRACTION ON DEPARTURE WHEN FLAPS UP SELECTED, EICAS MSG LE SLAT DISAGREE DISPLAYED LE SLAT DISAGREE CHECKLIST EXITED WHEN LE DISAGREEE MSG DID NOT EXTINGUISH WHEN LE ALTN FLAP SWITCHSDR IPXA2021080172330Warning Message · false activationATB, NO EMERG DECLAIRED, LANDED UNEVENTFULLY. AFTER TAKEOFF LE SLAT DISAGREE EICAS ON FLAP RETRACTION.PERFORMED BITE PROCEDURE, NO FAULT FOUND IAW FIM 27-51-00/101 AND FIM 27-81-00-815-803 SLATS OPERATIONAL TEST ALL TEST NORMAL.SDR IPXA2019122050219Switch · out of adjustATB - AFTER LIFTOFF RECEIVED A MAIN CARGO DOOR MESSAGE WITH LIGHT. ACFT REMAINED PRESSURIZED. AIR TURNBACK. MAIN CARGO DOOR SYSTEM MSG. TRANSFERRED MAIN CARGO DOOR INDICATION PER MEL/DMP 52-71-1. MAIN CARGO DOOR CLOSED/LATCHED/FAIRED.CKD & ADJUSTED MCD INTERLOSDR IPXA2019071944641Engine · failedINSPECTION TYPE:N/A ATB - ENGINE FAILED IN FLIGHT. ENGINE #1 REPLACED REF LOG PAGE 196334, ITEM 2.SDR IPXA2019062653729Slat System · malfunctionedATB -- L/E SLAT DISAGREE.TROUBLESHOT PER FIM 27-81-00 FIG 104, NO DISCREPANCIES FOUND AFTER SEVERAL HYD & ELECTRIC OPERATIONS. OK FOR SERVICE.SDR IPXA202002036044Door · inoperativeCREW DOOR OPEN LATCH MISSING NUT & REMOVED LATCH ASSY. LATCH ASSY ORDERED REQ 249304A JM 0557451 INSERT INSTALLED NUT TOP INBD. RE-INSTALLED LATCH ASSY REF. BOEING DRAWING 141N6015. DEFERRED PER E.O. B757-5210-70642-A.REMOVED CREW ENTRY DOOR HOLD OPEN LATCH ASDR IPXA2018111976044Nut · missingTHE CREW DOOR OPEN LATCH WAS MISSING A NUT. REMOVED THE LATCH ASSY. INSTALLED THE NUT AND INSTALLED THE LATCH ASSY IAW DRAWING 141N6015. OPEN.SDR IPXA2018070931492Light · inoperativeEMERGENCY LIGHT INOP EXIT. FOUND ALL BULBS BURNED OUT. RELAMPED ASSY PER MM 33-51-01-962-0001 OPS CHECKS NORMAL.SDR IPXA2018011225384Skin · puncturedINSPECTION TYPE:CRH I/B FLAP T/E LWR SURFACE WEDGE PANEL STA 161 HAS 3/16" PUNCTURE. REPAIRED PER SRM 57-53-01-2R-1, AND 51-70-06-0G.SDR IPXA2018011225383Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 241XKF HAS A BROKEN FASTENER HOLE. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018011825651Tee Fitting · corrodedINSPECTION TYPE: SEG4, BS 1180 FWD OF RAT FRAME CORRODED AROUND NUTPLATES. FABRICATED A NEW TEE IAW DWG 149N7528, INSTALLED THE NEW TEE IAW SRM 51-40-02-0G, AND DWG 149N7529.SDR IPXA2017033115708Smoke Goggles · crackedOBSERVER`S SMOKE GOGGLES HAD A CRACKED LENS. REPLACED THE SMOKE GOGGLES.SDR IPXA2017030614775Evas Unit · unsecureTHE CAPTAIN`S EVAS UNIT IS NOT SECURE. ILAYING IN STORAGE BIN. SECURED THE CAPTAIN'S EVAS UNIT IAW 2560-45127-H.SDR IPXA2016031600811Floor Panel · damagedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XBF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016031600799Floor Panel · damagedINSPECTION TYPE:C, MAIN DECK FLOOR PANEL 221XCF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016031000604Seat Track · corrodedINSPECTION TYPE:SEG,3 MAIN DECK AREA AT BS 440, RBL 45 SEAT TRACK FLANGE HAS CORROSION ON FASTENER HOLE. FABRICATED AND INSTALLED A REPLACEMENT SEAT TRACK AND REPAIR IAW SRM 53-00-52-2R-5.SDR IPXA2016030300306Floor Panel · damagedINSPECTION TYPE: SEG3, MCD FLOOR PANEL 232XSF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016031600798Nut Plate · corrodedINSPECTION TYPE: C, MAIN DECK BS 1040-1060, LBL 45-64 DOME NUTPLATE HAS SURFACE CORROSION AND DAMAGED DOME NUTS. FABRICATED NEW FLOOR SUPPORT TEE ON TR T16/11-2862 IAW DWG 144N5005-7.SDR IPXA2016031100638Floor Panel · delaminatedINSPECTION TYPE: SEGS, MCD FLOOR PANEL 231XFF DELAMINATED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016031100637Floor Panel · delaminatedINSPECTION TYPE: SEG3, MCD FLOOR PANEL 232XJF DELAMINATED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016031100636Floor Panel · delaminatedINSPECTION TYPE: SEG3, MCD FLOOR PANEL 231XJF. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016031000582Floor Panel · delaminatedINSPECTION TYPE: SEG3, MCD FLOOR PANEL 252XUF DELAMINATED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300309Floor Panel · not reportedINSPECTION TYPE:SEG3, MCD FLOOR PANEL 232XDF. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300308Floor Panel · brokenINSPECTION TYPE: SEG3, MCD FLOOR PANEL 251XJF BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300307Floor Panel · delaminatedINSPECTION TYPE: SEG3, MCD FLOOR PANEL 231XEF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300305Floor Panel · delaminatedINSPECTION TYPE: SEG3, MCD FLOOR PANEL 232XEF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300304Floor Panel · damagedINSPECTION TYPE: SEG3, MCD FLOOR PANEL 222XCF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300302Floor Panel · delaminatedINSPECTION TYPE: CMCD, FLOOR PANEL 232XHF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300299Floor Panel · delaminatedINSPECTION TYPE: SEG3, MCD FLOOR PANEL 252XHF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300297Floor Panel · delaminatedINSPECTION TYPE: SEG3, MCD FLOOR PANEL 232XWF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2016030300296Floor Panel · delaminatedINSPECTION TYPE:SEG3, MCD FLOOR PANEL 231XGF DELAMINATED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300295Floor Panel · delaminatedINSPECTION TYPE:SEG3, MCD FLOOR PANEL 231XDF DELAMINATED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300294Floor Panel · delaminatedINSPECTION TYPE:SEG 3, MCD FLOOR PANEL 222 XAF DELAMINATED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300292Floor Panel · delaminatedINSPECTION TYPE:SEG3, MCD FLOOR PANEL 252XJF BROKEN. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300291Floor Panel · delaminatedINSPECTION TYPE:SEG3, MCD FLOOR PANEL 232XGF DELAMINATED. FABRICCATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300290Floor Panel · delaminatedINSPECTION TYPE: SEG3, MCD FLOOR PANEL 222XBF DAMAGED. FABRICATED FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2016030300289Floor Panel · delaminatedINSPECTION TYPE:SEG3, MCD FLOOR PANEL 232XFF DELAMINATED. FABRICATED FLOOR PANEL 232XFF FROM A402H-48X144 BATCH 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016030300312Floor Panel · delaminatedINSPECTION TYPE:SEG3, MCD FLOOR PANEL 231XHF DELAMINATED. FABRICATED FLOOR PANEL 231XHF FROM A402H-48X144 BAT 2801694 IAW SREO B757-5320-9692-H.SDR IPXA2016031800910Floorbeam · corrodedINSPECTION TYPE:SEG, MAIN DECK AREA RT SIDE AT BS 1480, RBL 5 FLOORBEAM LOWER FLANGE HAS CORROSION UNDER NUTPLATE. ACCOMPLISHED REPAIR IAW EA 757-5365-27-A199 AND EO B757-5310-60238-A.SDR IPXA2016031700839Floorbeam · corrodedINSPECTION TYPE: C, MAIN DECK RT SIDE AT BS 1520 RBL24-RBL45 FLOORBEAM LOWER FLANGE HAS CORROSION ON NUTPLATE, REMOVED CORROSION IAW SRM 51-10-02-0G ACCOMPLISHED EO B757-5310-60220-A REV.SDR IPXA2016031700864Panel · delaminatedINSPECTION TYPE:C, RT VERTICAL STABILIZER LOWER FORWARD TORQUE BOX PANEL IS DELAMINATED. R & R PANEL IAW SRM 51-40-02-0G AND DWG 175N2001 SHEET.SDR IPXA2015101194658Skin · puncturedLEFT FUESLAGE SKIN PUNCTURE REPAIR BETWEEN BS 263 AND 270.5, S20L. REPAIRED IAW EO B757-5330-57793-B.SDR IPXA2015061790268Skin · puncturedSKIN PUNCTURED AT BS 263 TO BS 270.5 5 INCHES BELOW S20L. TEMP REPAIR IAW EO 5330-577934A TEMP REPAIR IAW EO 757-5330-57793-A. ACFT OK FOR SERVICE.SDR IPXA2014041482626Floor Panel · damagedINSPECTION: C10, MAIN CABIN FLOOR PANEL 241XGF IS DAMAGED. FABRICATED NEW FLOOR PANEL IAW REOB757-5320-9692.SDR IPXA2014040282491Floor Panel · damagedINSPECTION C10, MAIN CABIN FLOOR PANEL 231XVF IS DAMAGED. FABRICATED NEW FLOOR PANEL.SDR IPXA2014033182464Floorboard · damagedINSPECTION C-10, MAIN CABIN FLOORBOARD 241XCF HAS EDGE DAMAGE. FABRICATED FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014033182463Floorboard · damagedINSPECTION C-10, MAIN CABIN FLOORBOARD 241XAF IS DAMAGED. FABRICATED FLOORBOARD IAW SREO B757-5320 9 9692-H.SDR IPXA2014040782560Access Panel · corrodedINSPECTION C-10, CORROSION ON RT HORIZONTAL ACCESS PANEL 345HB. REPLACED ACCESSPANEL WITH NEW IAW SRM 51-40-02.