N454UP

Service difficulty reports · 250

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N454UP' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR IPXA10560872Frame · damagedINSPECTION TYPE:SP, REPLACE THE RT 660 FRAME FROM STR 13R TO STR 26R. REPLACED RT FRAME 660 IAW EO B757-5310-38469-A, ATS ER 10-3319, AND DWG 143N1012.Jun 24, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560311Floor Panel · puncturedINSPECTION TYPE:C4, UPON INSTALLATION OF FLOOR PANEL FOUND PUNCTURES IN UPPER SURFACE OF FLOOR PANEL FROM BS 480 TO BS 560, BL 0 TO RBL 25. FLOOR PANEL WAS REPALCED IAW EO B757-5320-9692-G.Jun 4, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560291Floor Panel · puncturedINSPECTION TYPE:C4, UPON INSTALLATION OF FLOOR PANEL FOUND PUNCTURES IN UPPER SURFACE OF FLOOR PANEL FROM BS 720 TO BS 820, BL 0 TO RBL 25. PANEL WAS REPLACED IAW EO B757-5320-9692-G.Jun 4, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560290Floor Panel · puncturedINSPECTION TYPE:C4, UPON INSTALLATION OF FLOOR PANEL FOUND PUNCTURES IN UPPER SURFACE OF FLOOR PANEL FROM BS480 TO BS560, BL0 TO RBL25. FLOOR PANEL WAS REPLACED IAW EO B757-5320-9692-G.Jun 4, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560345Floor Panel · damagedINSPECTION TYPE:C4, DUE TO FLOORBEAM SPLICE, FLOOR PANEL ATTACHING HOLES WILL FALL OUT IN RADIUS, FLOOR PANEL REQUIRES REPALCEMENT, FROM BS 1055-1100 LBL 25-45. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.Jun 3, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560344Floor Panel · damagedINSPECTION TYPE:C4, DUE TO FLOORBEAM SPLICE, FLOOR PANEL ATTACHING HOLES WILL FALL OUT IN RADIUS, FLOOR PANEL REQUIRES REPLACEMENT, FROM BS 1100-1200 LBL 25-45. FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.Jun 3, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560356Floor Support · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ON LONGIDUDINAL FLOOR BEAM AT LBL 25 BS 1040-1080. R & R BEAM IAW SRM 51-40-02.Jun 1, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560288Support · damagedINSPECTION TYPE:C4, AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT CLIP DAMAGED AT BS 1480, LBL 20, WL 155. FLOOR TO SIDEWALL SUPPORT WAS REPLACED IAW SRM 51-40-02-0G.May 28, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560155Support · damagedINSPECTION TYPE:C4, AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT CLIP DAMAGED AT BS 1500 LBL 16.5 WL 155. REMOVED CLIP, REMOVED DAMAGE & FOUND TO BE WITHIN REPAIRABLE LIMITS, HFEC NO CRACKS FOUND, ALODINED PRIMED & REINSTALLED IAW SRM 51-20-01-0G, SRM 53-00-53-1A.May 28, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560117Splice · corrodedINSPECTION TYPE:C4, FLOOR PANEL SPLICE IS CORRODED IN AFT CARGO BAY BS 1510 REPLACED SPLICE STRAP IAW SRM 51-40-05, SRM 51-40-08-0G, SRM 51-40-02, SRM 53-00-53-1A, AMM 51-21-04-7, AMM 51-21-10-7, SRM 53-60-53-0I.May 25, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560116Splice · corrodedINSPECTION TYPE:C4, FLOOR PANEL SPLICE IS CORRODED IN AFT CARGO BAY BS 1330. REPLACED SPLICE STRAP IAW SRM 53-00-53-1A, SRM 51-40-05-0G, SRM 51-40-08-0G, AMM 51-21-04-7, AMM 51-21-10-7, SRM 51-40-02-0G, SRM 53-60-53-01.May 25, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560848Former · damagedINSPECTION TYPE:C4, WHILE CLOSING WING TO BODY FAIRING FOUND FAIRING FORMER TO BE DAMAGED AT 3 EA NUTPLATE ATTACH POINTS BS860, RBL44, 47 AND66 REPAIRED IAW SRM 51-70-12-0G.May 24, 2010 · N454UP · Boeing 75724APF · Aerodynamic FairingsSDR IPXA10560115Splice · corrodedINSPECTION TYPE:C4, AFT CARGO COMPARTMENT, NR 3 FLOOR PANEL SPLICE IS CORRODED. REPLACED SPLICE STRAP IAW SRM 53-00-53-1A, SRM 51-40-05-0G, SRM 51-40-08-0G, AMM 51-21-04-7, AMM 51-21-10-7, SRM 51-40-02-0G, SRM 53-60-53-0I.May 24, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560262Skin · debondedINSPECTION TYPE:C4 RT WING OTBD AFT FLAP LWR SURFACE 26" FROM OTBB END 3" UP FROM L/E AREA OF POSSIBLE DISBOND NOTED. REPAIRED IAW SRM 51-70-04.May 23, 2010 · N454UP · Boeing 75724APF · Trailing Edge FlapsSDR IPXA10560470Floor Support · corrodedINSPECTION TYPE:C4 MULTIPLE AREAS OF CORROSION ON LONGITUDINAL FLOORBEAM AT LBL 45 BS 1040 TO 1080. BLENDED MULTIPLE AREAS OF CORROSION ON FLOORBEAM, FOUND FLOORBEAM OUT OF LIMITS REMOVED FLOORBEAM, FABRICATED A NEW FLOORBEAM, LOCATED HOLES, DRILLED THRU HOLEMay 18, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560469Floor Support · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ON LONGITUDINAL FLOORBEAM AT RBL 45 BS 1040 TO BS 1080. BLENDED MULTIPLE AREAS OF CORROSION ON FLOORBEAM, FOUND FLOORBEAM OUT OF LIMITS, REMOVED FLOORBEAM, FABRICATED NEW FLOORBEAM IAW DWG, LOCATED FASTENER HOLMay 18, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560838Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ON SEAT TRACK AT LBL 60 BS 895-1080. R & R TRACK IAW SRM51-40-02.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560698Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ALONG SEAT TRACK AT RBL 60, BS 1080 TO 1186 (REPAIR IS A MINOR/FAB FLOOR PANEL MAJOR) FABRICATED FLOOR PANEL IAW EO B757-5320-9692-G.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560657Floorbeam · corrodedINSPECTION TYPE:C4, TRANSVERSE FLOORBEAM UPPER CHORD FLANGE IS CORRODED AT BS 1100 LBL 25-45 WL 208. UPON INVESTIGATION FOUND 100 PERCENT MATERIAL LOSS OF BS 1100 FLOORBEAM, ACCOMPLISHED CONDUCTIVITY TEST OF BEAM, REMOVED FLOORBEAM, FABRICATED NEW REPLACEMENTMay 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA0560652Doubler · damagedINSPECTION TYPE:C4, MAIN CARGO DOOR, INNER SURFACE, FRAME AT BS 487 BETWEEN STR 14-17 HAS SEVERAL SCREW STARTS. REMOVED GOUGED AREA, UT MEASURED THICKNESS FORMED NEW DOUBLER FOUND GOUGED DOUBLER OUT OF LIMITS, ROUTED NEW DOUBLER FOR HEAT TREAT, DRILLED ALODINMay 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Plate/SkinSDR IPXA0560620Frame · damagedINSPECTION TYPE:C4, SCREW STRIKE ON INBD FLANGE OF FRAME AT B/S 680, BETWEEN STRINGERS 15R AND 16R. REPAIRED IAW EO NR 10-2866 DATED 6-16-10.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560595Floorbeam · corrodedINSPECTION TYPE:C4, CORROSION ON FLOORBEAM UPPER CHORD BS 879, LBL 48-LBL 55. REPAIRED IAW ATS ER 10-2838.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560581Beam · corrodedINSPECTION TYPE:C4, CORROSION COMMON TO FASTENER HOLE IN STUB BEAM BS 901, RBL 49, WL 208. REPAIRED IAW ER NR 10-3017, DATED 16-JUN-2010.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA10560580Beam · corrodedINSPECTION TYPE:C4, CORROSION ON B/S 900 STUB BEAM UPPER CHORD LBL49-55 REPAIRED IAW ATS ER NR 10-3017.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, StructureSDR IPXA10560501Floor Support · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORRISION ON LOGNITUDINAL FLOORBEAM AT LBL 25 - B.S. 895 TO B.S. 1070. REPLACED PART.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560500Floor Support · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ON LONGITUDINAL FLOORBEAM AT LBL 45 BS 895 TO 1040. REPLACED PART.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560476Floor Support · corrodedINSPECTION TYPE:C4, FLOOR SUPPORT CORRODED. FOUND FLOOR SUPPORT OUT OF LIMITS, REPLACED IAW SRM 53-40-51-01I, SRM 51-40-02-0G.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560475Floor Support · crackedINSPECTION TYPE:C4, FLOOR SUPPORT CRACKED BS 900, RBL 15, FLOOR SUPPORT OUT OF LIMITS, REPLACED IAW SRM 53-40-51-0I1, SRM 51-40-02-0G.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560473Floor Support · corrodedINSPECTION TYPE:C4, AREAS OF CORROSION ON LONGITUDINAL FLOORBEAM AT RBL 45 BS 895 TO BS 1040. R& R LONGITUDINAL FLOORBEAM UPPER CHORD IAW SRM 51-40-02-0G, SRM 51-40-05.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Miscellaneous StructureSDR IPXA10560472Floorbeam · corrodedINSPECTION TYPE:C4, UPPER SURFACE OF FLOORBEAM SUPPORT CORRODED COMMON TO 2 EA FASTENER HOLES BS 1054, RBL 53 TO RBL 57, WL 207. R & R FLOOR BOARD SUPPORT IAW SRM 51-40-02-0G, 51-21-04-7.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560471Floorbeam · corrodedINSPECTION TYPE:C4, FLOORBEAM FLANGE CORRODED AT BS 900, LBL 0-25, WL 208 BLENDED FLOORBEAM FLANGE AT BS 900, FOUND TO BE OUT OF LIMITS. REMOVED FLOORBEAM, FABRICATED NEW REPLACEMENT FLOORBEAM. DRILLED TRIMED ALODINED, PRIMED AND INSTALLED NEW FLOORBEAM IAW SMay 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560468Floorbeam · corrodedINSPECTION TYPE:C4, UPPER SURFACE OF FLOORBOARD SUPPORT CORRODED AT FASTENER HOLE B/S 1054, RBL34, WL 207. R & R FLOOR SUPPORT IAW SRM 51-40-02-0G, SRM 51-40-06-0G, AND DWG 144N5005.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560459Floorbeam · corrodedINSPECTION TYPE:C4, FLOOR SUPPORT FLANGE CORRODED AT BS 1016, LBL 25 TO LBL 45, WL 208. REMOVED FABRICATED AND REPLACED FLOOR SUPPORT TEE IAW SRM 51-40-05, SRM 51-10-02-0G STG R NR 8.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560458Frame · damagedINSPECTION TYPE:C4, SCREW STRIKE ON INBD FLANGE OF FRAME AT B/S 640, BETWEEN STRINGERS 15R AND 16R. REPAIRED SCREW STRIKE ON INBD FLANGE OF FRAME IAW SRM 51-00-07-1A1, SRM 51-40-05-0G AND ER 10-2870.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560427Floorbeam · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1420, LBL 45.5 TO LBL 60 FLOORBEAM UPPER SURFACE IS CORRODED AROUND FASTENER HOLE. REPAIR IAW ATS ER 10-2875.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560425Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ALONG SEAT TRACK AT LBL 25 BS 1075 TO 1180. REPLACED SEAT TRACK IAW DWG 144N5024, SRM 51-40-02.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560405Floorbeam · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1540, LBL45.5 TO LBL 60 FLOORBEAM UPPER SURFACE IS CORRODED AROUND FASTENER HOLE. REPAIR IAW ATS ER 10-2852.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560391Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ALONG SEAT TRACK AT LBL 45 BS 1075-1180. FOUND TO BE OUT OF LIMITS R & R WITH REPLACEMENT PART.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560389Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ALONG SEAT TRACK AT RBL 45 BS 1075 TO 1180. FOUND TO BE OUT OF LIMITS R & R WITH REPLACEMENT PART.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560355Seat Track · corrodedINSPECTION TYPE:C4, MULTIPLE AREAS OF CORROSION ALONG SEAT TRACK OF LBL 60 BS 1080- 1186. R & R SEAT TRACK IAW SRM 51-40-02.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560309Floorbeam · corrodedINSPECTION TYPE:C4, CORROSION ON UPPER SURFACE OF FLOORBEAM COMMON TO 2 EA FASTNERS HOLES. BS 1200, RBL 48 TO RBL 52, WL 207. REPAIRED IAW ATS 10-2828.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, Floor BeamSDR IPXA10560315Seat Track · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1661 TO STA 1681.8 LBL 45.5 SEAT TRACK HAS INBD FLANGE IS CORRODED AROUND FASTENERS HOLE. R & R SEAT TRACK IAW SRM 51-40-02-0G.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560313Frame · gougedINSPECTION TYPE:C4, 2 EACH SCREW STRIKESON INBD FLANGE OF FRAME AT BS 780, BETWEEN STRINGERS 15L & 16L. REPAIRED IAW ATS ER 10-2882.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560312Frame · gougedINSPECTION TYPE:C4, 2 EACH SCREW STRIKES ON INBD FLANGE OF FRAME AT BS 740, BETWEEN STRINGERS 15L AND 16L. REPAIRED IAW ATS ER 10-2882.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560308Frame · gougedINSPECTION TYPE:C4, 2 EACH SCREW STRIKES ON INBD FLANGE OF FRAME AT BS 700, BETWEEN STRINGERS 15L AND 16L. REPAIRED IAW ATS ER 10-2882.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560307Frame · gougedINSPECTION TYPE:C4, 2 EACH SCREW STRIKES ON INBD FLANGE OF FRAME AT BS 820, BETWEEN STRINGERS 15L AND 16L. REPAIRED IAW ATS ER 10-2882.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Main, FrameSDR IPXA10560199Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO STA 1400, LBL 60 FLOOR PANEL HAS 1EA INSERTS MISSING. FLOOR PANEL ORIGINAL FOUND TO BE OUT OF LIMITS IAW SRM 53-00-50-IA 1 LOCATED MATERIAL, THEN CUT OUT SIZE, DRILLED AND INSTALLED INSERTS APPLIED SAFETY WALK NON-SKID FINISH.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor PanelSDR IPXA10560198Seat Track · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1180 TO STA 1200, LBL 45.5 SEAT TRACK HAS INBD AND OTBD FLANGE CORRODED GROUND FASTENER HOLES. BLENDED CORROSION FROM SEAT TRACK, FOUND IT TO BE OUT OF LIMITS, REMOVED DAMAGED SEAT TRACK, RECEIVED A NEW REPLACEMENT SEAT TRACMay 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560197Seat Track · corrodedINSPECTION TYPE:C4, MAIN CARGO STA 1180 TO STA 1200, LBL 24.75 SEAT TRACK HAS INBD AND OTBD FLANGE CORRODED GROUND FASTENERS HOLES. REMOVED CORROSSION FROM THE SEAT TRACK. FOUND IT OUT OF ALLOWABLE DAMAGE. R & R SEAT TRACK, DRILLED, PRIME AND PAINTED NEW REPMay 17, 2010 · N454UP · Boeing 75724APF · Fuselage, Seat/Cargo Attach FittingsSDR IPXA10560129Floor Panel · dentedINSPECTION TYPE:C4 MCB FLOORBOARD PANEL DENTED BS 900 - 1016 LBL 45 - 62 FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.May 17, 2010 · N454UP · Boeing 75724APF · Fuselage Floor Panel
Back to N454UP