INSPECTION TYPE:C4, FLOOR SUPPORT FLANGE CORRODED AT BS 1016, LBL 25 TO LBL 45, WL 208. REMOVED FABRICATED AND REPLACED FLOOR SUPPORT TEE IAW SRM 51-40-05, SRM 51-10-02-0G STG R NR 8.