N455UP
Service difficulty reports · 211
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N455UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N455UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2014082984103Tee Fitting · corrodedINSPECTION 10S2, LOWER WING TO BODY FAIRING TEE FITTING HAS CORROSION BS 1060 BETWEEN LBL 18 - 44, FWD OF MLG W/W DOORS. INSTALLED NEW TEE FITTING AND REPAIR ANGLES IAW SRM 51-40-02-0G AND SRM 51-70-12-0G, STEP 8 & 9.SDR IPXA2014081884011Floor Panel · damagedINSPECTION CP10, MAIN DECK FLOOR PANEL 242XDF HAS BROKEN INSERTS. R & R BROKEN INSERTS IAW SREO M-5320-38342-B.SDR IPXA2014081884010Floorboard · damagedINSPECTION CP 10, MAIN DECK FLOORBOARD 241XCF HAS EDGE DAMAGE AND BROKEN INSERTS. FABRICATED NEW FLOORBOARD IAW SREO 5320-9692-H.SDR IPXA2014081884009Floorboard · damagedINSPECTION CP10, MAIN DECK FLOORBOARD 241XBF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014081884007Floor Panel · damagedINSPECTION CP10, MAIN DECK FLOOR PANEL 242XJF HAS EDGE DAMAGED AND BROKEN INSERTS. FABRICATED NEW FLOOR PANEL IAW SREO 5320-9692-H.SDR IPXA2014081884006Floor Panel · delaminatedINSPECTION CP10, MAIN DECK FLOOR PANEL 241XHF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA2014081884005Floorboard · damagedINSPECTION CP10, MAIN DECK FLOORBOARD 242XFF HAS EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA2014052883104Compressor · stalledNR 2 ENGINE EXPERIENCED SEVERE COMPRESSOR STALLS. CAPTAIN DECLARED EMERGENCY AND RETURNED TO DEPARTURE. REPLACED NR 2 ENGINE IAW TC5001RR & TC5002RR. OPS CHECKED NORMAL.SDR IPXA13577579Skin · dentedINSPECTION TYPE:C1C9, NR 10 SLAT UPPPER T/E HAS DAMAGE 32 INCHES FROM OTBD END AND 6 INCHES FROM T/E COMPLIED WITH EO 757-5780-50Z17-A.SDR IPXA3577483Skin · damagedINSPECTION TYPE:C1C9, NR 7 SLAT L/E SKIN DEFORMED & CREASED AT FASTENER HEADS. NR 53-26 EVALUATED SKIN CREASE AND FOUND TO HAVE MINOR DENT FORWARD AND AFT OF SLAT NOSE BEAM CAUSING CREASE DEFORMATION IAW SRM 51-10-01-0G. DIMENTION OF DENT AT FWD NR 7 SLASDR IPXA2575281Seal · damagedCAPTAINS SLIDING WINDOW LATCH BINDING. REPLACED DAMAGED L2 WINDOW PRESSURE SEAL IAW MM 56-11-53-404.SDR IPXA11566211Lamp · inoperativeEIGHT LAMPS INOP IN EMERGENCY LIGHT ASSY. RELAMPED EIGHT LAMPS IN EMERGENCY EXIT SIGN IAW AMM 33 51 01 2.SDR IPXA1565729Skin · scratchedINSPECTION TYPE:C4, EXTERNAL FUSELAGE LT SIDE UPPER LOBE EXTERIOR SKIN SCRATCHED IN 3 PLACES BETWEEN BS1480 AND BS 1500 ABOVE STR 17L. REMOVED DAMAGE ORIGINAL THICKNESS .040 REMOVED .007 REMAINING .033 OUT OF LIMITS IAW SRM 53-00-01-1A-1. REMOVED DAMAGE AND SDR IPXA1565716Frame · chafedINSPECTION TYPE:C4, STA 1060 FRAME INBD FORE IS CHAFED AT STRINGER 15R. BLENDED OUT DAMAGE. FABRICATED AND INSTALLED REPAIR DOUBLER IAW EA 110 155 IR AND EO B757-5310-41937-A.SDR IPXA11565483Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 560 TO 620, LBL 46 TO LBL 61, EXPOSED COMPOSITES AND PUNCTURES. REPLACE PANEL IAW EO B757-5320-9692-G.SDR IPXA11565456Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 1100 TO 1180 LT SIDE DELAMINATED ON BOTTOM AND INSERTS CORRODED. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565455Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD, AT STA 1060- STA 1100, LBL 45 TO LBL 61 INSERTS BROKEN OUT, INSERTS CORRODED EDGE DAMAGE. REPLACE FLOORBOARD IAW EO B757-5320-9692-GSDR IPXA11565454Floorboard · crushedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 1681 TO STA 1720 EDGE DAMAGE, CRUSHED AND CRACKED. RT SIDE REPLACE FLOORBOARD IAW BO B757-5320-9692-G.SDR IPXA11565452Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 560 TO 620 LBL 26 TO LBL 45 HAS EXPOSED COMPOSITES. REPLACE FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565451Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 720 TO 780 RBL 46 TO RBL 61 HAS SEVERAL BAD INSERTS AND BROKEN CORNER. REPLACE FLOORBOARD IAW B757-5320-9692-G.SDR IPXA11565450Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 480 TO 560, RBL 26 TO RBL 45 HAS AREAS OF DELAMINATION. REPLACE PANEL IAW EO B757-5320-9692-G.SDR IPXA11565448Floorboard · crushedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 1320-STA 1420, LBL 45.5 TO LBL 61, CRUSHED AT AFT END AND SEVERAL INSERTS CORRODED. REPLACE PANEL IAW EO B757-5320-9692-G.SDR IPXA11565446Floorboard · crushedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 1100 TO STA 1180 BL 0 TO RBL 25 FWD EDGE CRUSHED. REPLACE FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565445Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 900 TO 1020, LBL 1 TO LBL 26 HAS EDGE DAMAGE. REPLACE FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA11565444Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 440 TO 480, LBL 26 TO LBL 45 HAS DELAMINATION AND PUNCTURES. REPLACE FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1565284Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 340 TO 440 LBL 46 TO LBL 61 HAS NUMEROUS AREAS OF DELAMINATION AND PUNCTURES. REPLACED PANEL IAW EO 757-5320-9692-G.SDR IPXA1565328Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT STA 440 TO 480, RBL 1 TO RBL 26 FLOORBOARD HAS DELAMINATION AND BROKEN EDGES. REPLACED FLOORBOARD REF EO B757-5320-9692G.SDR IPXA1565294Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 440 TO 480 LBL 46 TO LBL 61 HAS AREAS OF DELAMINATION AND EDGE DAMAGE. REPLACE PANEL IAW B757-5320-9692G.SDR IPXA11565520Floor Support · corrodedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT STA 1180 TO 1200, LBL 24 FLOOR SUPPORT HAS LIGHT CORROSION AT FASTENER HOLES SPLICED IN NEW FLOOR SUPPORT IAW SRM 53-00-52-2R-5.SDR IPXA1565718Floorbeam · corrodedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT STA 1681, LBL 42" TO LBL 54" FLOOR HAS CORROSION. REMOVED CORROSION ORIGINAL THICKNESS .071 LOSS .013 WITH .058 REMAINING IS OUT OF LIMITS IAW SRM 53-00-51-1A . ACCOMPLISHED BLEND REPAIR FOR EXTENDED LIMITS IAW EASDR IPXA11565518Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 560 TO 620, RBL 46 TO RBL 61 IS PUNCTURED AND CRACKED. REPLACED FLOORBOARD.SDR IPXA11565484Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 340 TO 440, LBL 1 TO LBL 24 HAS NUMEROUS PUNCTURES. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692.SDR IPXA11565482Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 1060 TO 1100, BL 0 TO LBL 2 AFT EDGE DAMAGED, CRUSHED, FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA11565449Floor Panel · damagedINSPECTION TYPE:C4 MAIN CARGO COMPARTMENT FLOOR PANEL AT STA 879 TO 900 RBL 26 TO RBL 45 HAS DAMAGE REPLACED PANEL PER B757-5320-9692-GSDR IPXA11565447Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 780 TO 820 RBL 46 TO RBL 61 HAS EDGE DAMAGE AND BROKEN CORNER. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1565331Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 820 TO 879, RBL 46 TO RBL 61 HAS SEVERAL PUNCTURES. REPLACED PANEL IAW EO B757-5320-9692G.SDR IPXA1565330Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 340 TO 440, RBL 1 TO RBL 24 HAS AREAS OF EDGE DAMAGE. REPLACED PANEL IAW EO B757-5320-9692G.SDR IPXA1565329Floorboard · brokenINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 620 TO 720, LBL 46 TO LBL 61 HAS A BROKEN CORNER AND A DRILLED OFF SCREW. REPLACED PANEL IAW EO B757-5320-9692G.SDR IPXA1565327Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 480 TO 560 LBL 26 TO LBL 45 HAS DELAMINATED AND PUNCTURES. REPLACED PANEL IAW B757-5320-9692G.SDR IPXA1565326Floor Panel · brokenINSPECTION TYPE:C4, MAIN CARGO FLOOR PANEL 232XHF IS BROKEN. FABRICATED NEW PANEL IAW EO B757-5320-9692G.SDR IPXA1565325Floor Panel · delaminatedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOOR PANEL 251XLF, DELAMINATED ON TOP SURFACE. REPLACED PANEL 251XLF IAW B757-5320-9692G.SDR IPXA1565324Floorboard · delaminatedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 879 TO 900 LBL 1 TO LBL 26 IS DELAMINATED. REPLACED FLOOR PANEL.SDR IPXA1565296Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 480 TO 560, LBL 46 TO LBL 61 HAS AREAS OF DELAMINATION, PUNCTURES AND EDGE DAMAGE. REPLACE FLOOR PANEL IAW EO B757-5320-9692G.SDR IPXA1565293Floor Panel · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 490 TO 480 RBL 46 TO RBL 61 HAS CORNER DAMAGE AND SEVERAL CORRODED INSERTS. REPLACED FLOOR PANEL IAW EO B757-5320-9692G.SDR IPXA1565291Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 560 TO 620 LBL 1 TO LBL 26 HAS EXPOSED COMPOSITES AND PUNCTURES. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1565290Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 820 TO 879 RBL 1 TO RBL 26 HAS EDGE DAMAGE. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1565289Floorboard · cutINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 820 TO 879 LBL 1 TO LBL 26 HAS LARGE CUT. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1565286Floor Panel · brokenINSPECTION TYPE:C4, INSERTS CORRODED AND BROKEN ON BOTTOM SIDE AT MAIN CARGO COMPARTMENT FLOOR PANEL 252 XSF. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-G.SDR IPXA1565283Floorboard · damagedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 345 RBL 26-RBL 45 HAS EDGE DAMAGE. REPLACED FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1565281Floorboard · puncturedINSPECTION TYPE:C4, MAIN CARGO COMPARTMENT FLOORBOARD AT STA 440 TO 480 LBL 26 TO LBL 45 HAS EDGE DAMAGE AND NUMEROUS PUNCTURES. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G.