N457UP
Service difficulty reports · 307
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N457UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N457UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2018030227034Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227033Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XGF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227032Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227031Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227030Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227029Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 232XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227027Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 231XEF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227025Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 222XCF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227024Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 221XCF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227023Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 222XAF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227022Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 221XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227021Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 222XBF IS DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2018030227020Floor Panel · delaminatedINSPECTION TYPE: C, MAIN DECK FLOOR PANEL 221XAF IS DELAMINATED. FABRCIATED A NEW FLOOR PANEL IAW SREO B757-5320-9692-K.SDR IPXA2017062018440A/C Pack · failedBURNING ODOR AND SMOKE IN COCKPIT DURING FINAL APPROACH TO LANDING, NO SMOKE OR FIRE WARNINGS. ACCOMPLISHED FIM 21-00-01 PAG 301. RAN LEFT PACK WITH BOTH ENGINES RUNNING AND BOTH BLEEDS ON , LEFT PACK OK. ALSO RUN LEFT PACK WITH THE PROPER BLEED ON LEFT PACKSDR IPXA2017061718283Connector · disconnectedLT ENGINE OVERTEMP EGT, NO OVERSPEED INDICATED IAW ENGINEERING N3 REGISTERED 99.2 FOR 5 SECSC/W FIM71-05-00-815-824-R00 FIG 121 C/W ZONE A INSP FOUND DEDICATED GENERATOR CONNECTOR DISCONNECTED. INSTALLED CONNECTOR AND PERFORMED AN OP CHECK IAW MM 73-21-08SDR IPXA2017051917309Sign · inoperativeONE BULB BURNED OUT IN THE FLIGHT DECK EMERGENCY EXIT SIGN IAW AMM 33-51-01-962-001. REPLACEDLAMPED EMERGENCY EXIT SIGN IAW AMM 33-51-01-962-00SDR IPXA2017041116058Smoke Goggles · damagedOBSERVER SMOKE GOGGLE DAMAGED. REPLACED DAMAGED SMOKE GOGGLE IAW MM 25-60-00.SDR IPXA2016112610989Guard · brokenEMERGENCY EXIT LIGHT SWITCH GUARD BROKEN (SPRING). R&R EMERGENCY EXIT LIGHT SWITCH GUARD PER AMM 20-00-00. OPS CHECK GOOD.SDR IPXA2016030800492Support Angle · corrodedINSPECTION TYPE:C10, CORROSION NOTED AT BS 1060 ON FAIRING SUPPORT ANGLE LOWER SURFACE LBL 7 TO RBL 9. PERFORMED REPAIR IAW SRM 51-70-12-0G.SDR IPXA2016030100197Structure · damagedINSPECTION TYPE:C10, MCD HAS SCREW STRIKE AT LOWER BS 487. SCREW STRIKE DAMAGE .030 DEEP, ORIGINAL MATERIAL THICKNESS .090, REMAINING .060 OUT OF LIMITS IAW 52-30-02. REMOVED, FABRICATED AND INSTALLED NEW 65-25327-20, FRAME DOUBLE IAW DWG 65-25327, REV U.SDR IPXA2016022499827Cargo Track · corrodedINSPECTION TYPE:C, 10AFT CARGO COMPARTMENT DOOR THRESHOLD FORWARD TIE DOWN FITTING AT BS 1385 IS CORRODED ON THE FORWARD SIDE. R & R CORRODED FITTING IAW SRM 51-40-02 AND BAC DWG 146N8560, REV F.SDR IPXA2016022800034Access Panel · crackedINSPECTION TYPE:C10, NLG CEILING UPPER SURFACE, CLIP AT BS 270.5, BL 0 CRACKED INSIDE ACCESS PANEL 113AZ. REMOVED, FABRICATED & INSTALLED NEW CLIP IA DWG 141N9910, REV 4.SDR IPXA2014102284664Stringer · corrodedSTRINGER 29L CORRODED AT BS 1459. REPAIR COMPLETED ON RCD 670271/2.SDR IPXA2014031982340Floorboard · damagedINSPECTION C, UPPER CARGO BAY FLOORBOARD 241XAF HAS EDGE DAMAGE AND CORE AROUND FASTENER HOLE MISSING. FABRICATED FLOORBOARD IAW SREO B757- 5320-9692-H.SDR IPXA2013102500684Lamp · inoperativeEMERGENCY LIGHT INOPERATIVE. REPLACED LAMP IAW MM 33-51-06-02.SDR IPXA12573698Skin · crackedFUSELAGE SKIN CRACKED STA 1650 STR 24R 25R. REPAIRED IAW EO B757-5330-47289-A.SDR IPXA12572966Frame · damagedINSPECTION TYPE: C, BS 540, STR 16R, FRAME IS DAMAGED. REPAIRED DENTED FRAME IAW EO B757-5310-46710-A.SDR IPXA12572963Seat Track · corrodedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT BS 1148, RBL 26 CORRODED. FABRICATED AND INSTALLED NEW SECTION OF SEAT TRACK.SDR IPXA12572948Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 241XHF COMPOSITE IS SEPARATING. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12572947Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 241XGF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12572946Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 241XMF DELAMINATED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12572940Floor Panel · corrodedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 252XUF IS CORRODED. FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12572939Floor Panel · damagedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT FLOOR PANEL 241XCF IS DAMAGED FABRICATED NEW FLOOR PANEL IAW EO B757-5320-9692-HSDR IPXA2572926Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 242XDF DAMAGED. FABRICATE FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA2572885Floorboard · delaminatedINSPECTION TYPE: C, PANEL NR 251 XFF HAD EDGE DAMAGE AND DELAMINATION. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572729Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO BAY FLOORBOARD 241XFF DELAMINATED. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572728Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 241XKF HAS DELAMINATION, AND DAMAGED INSERT HOLES. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572727Floorboard · delaminatedINSPECTION TYPE: C, MAIN CARGO BAY FLOORBOARD 242XBF DELAMINATION. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572726Floor Panel · delaminatedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 231XGF DELAMINATED, EDGE DAMAGED AND BROKEN FIBERS. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572724Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 232XHF HAS MISSING INSERTS AND HAS TOOLING MARKS. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572723Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 251XRF HAS SEVERAL AREAS OF TOOL DAMAGE. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572722Floorboard · crackedINSPECTION TYPE:C, MAIN CARGO FLOORBOARD 242XLF CRACKED 18"AFT. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572721Floorboard · crackedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 241XCF CRACKED 79" AFT. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2572831Floorboard · delaminatedINSPECTION TYPE:C, FLOORBOARD 252XCF DELAMINATED. FABRICATED NEW FLOORBOARD IAW WO B757-5320-9692-H.SDR IPXA12572693Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 232XCF HAS DELAMINATION. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12572692Floor Panel · damagedINSPECTION TYPE: C, FLOOR PANEL 242XFF HAS DELAMINATION EDGE DAMAGE AND BROKEN FIBERS. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12572689Floor Panel · delaminatedINSPECTION TYPE: C, FLOOR PANEL 232XBF HAS DELAMINATION. FABRICATED FLOOR PANEL IAW EO B757-5320-9692-H.SDR IPXA12572706Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 251XQF MISSING INSERTS. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572705Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 251XMF EDGE DAMAGED FWD INBD CORNER. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA12572704Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 252XRF EDGE DAMAGE AND MISSING INSERTS. FABRICATED MAIN CARGO FLOORBOARD IAW EO B757-5320-9692-H.